AVAlexandre Verney

Alexandre Verney

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexandre Verney has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic

    by Alexandre Moly, Thomas Costecalde, Félix Martel, Matthieu Martin, Christelle Larzabal, Serpil Karakas, Alexandre Verney, Guillaume Charvet, Stephan Chabardes, Alim Louis Benabid, et al.

    Objective. The article aims at addressing 2 challenges to step motor brain-computer interface (BCI) out of laboratories: asynchronous control of complex bimanual effectors with large numbers of degrees of freedom, using chronic and safe recorders, and the decoding performance stability over time without frequent decoder recalibration. Approach. Closed-loop adaptive/incremental decoder training is one strategy to create a model stable over time. Adaptive decoders update their parameters with new incoming data, optimizing the model parameters in real time. It allows cross-session training with multiple recording conditions during closed loop BCI experiments. In the article, an adaptive tensor-based recursive exponentially weighted Markov-switching multi-linear model (REW-MSLM) decoder is proposed. REW-MSLM uses a mixture of expert (ME) architecture, mixing or switching independent decoders (experts) according to the probability estimated by a ‘gating’ model. A Hidden Markov model approach is employed as gating model to improve the decoding robustness and to provide strong idle state support. The ME architecture fits the multi-limb paradigm associating an expert to a particular limb or action. Main results. Asynchronous control of an exoskeleton by a tetraplegic patient using a chronically implanted epidural electrocorticography (EpiCoG) recorder is reported. The stable over a period of six months (without decoder recalibration) eight-dimensional alternative bimanual control of the exoskeleton and its virtual avatar is demonstrated. Significance. Based on the long-term (>36 months) chronic bilateral EpiCoG recordings in a tetraplegic (ClinicalTrials.gov, NCT02550522), we addressed the poorly explored field of asynchronous bimanual BCI. The new decoder was designed to meet to several challenges: the high-dimensional control of a complex effector in experiments closer to real-world behavior (point-to-point pursuit versus conventional center-out tasks), with the ability of the BCI system to act as a stand-alone device switching between idle and control states, and a stable performance over a long period of time without decoder recalibration.


  • Open Access

    An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic

    by Alexandre Moly, Thomas Costecalde, Felix Martel, Christelle Larzabal, Serpil Karakas, Alexandre Verney, Guillaume Charvet, Stephan Chabardes, Alim Louis Benabid, Tetiana Aksenova

    Brain-computer interfaces (BCIs) still face many challenges to step out of laboratories to be used in real-life applications. A key one persists in the high performance control of diverse effectors for complex tasks, using chronic and safe recorders. This control must be robust over time and of high decoding performance without continuous recalibration of the decoders. In the article, asynchronous control of an exoskeleton by a tetraplegic patient using a chronically implanted epidural electrocorticography (EpiCoG) implant is demonstrated. For this purpose, an adaptive online tensor-based decoder: the Recursive Exponentially Weighted Markov-Switching multi-Linear Model (REW-MSLM) was developed. We demonstrated over a period of 6 months the stability of the 8-dimensional alternative bimanual control of the exoskeleton and its virtual avatar using REW-MSLM without recalibration of the decoder.

  • EMY: a dual arm exoskeleton dedicated to the evaluation of Brain Machine Interface in clinical trials

    by B. Moriniere, A. Verney, N. Abroug, P. Garrec, Y. Perrot

    EMY (Enhancing MobilitY) is an exoskeleton dedicated to the evaluation of Brain Machine Interface during clinical trials. This paper presents the first version of EMY restricted to upper limbs with four actuated joints per arm. Since an evaluation of a BMI controlled exoskeleton by a disabled person requires clinical trials, a risk management process should be conducted with medical standards as references. More than an exhaustive architecture description of EMY, this paper details relationships between risk management and the proposed technical solutions in order to justify design options. EMY's design is upgradable and future versions of EMY will concern the addition of lower limbs and prehension capability to ultimately obtain a full-body exoskeleton suitable for testing brain controlled locomotion and manipulation tasks.