Benzhe Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benzhe Zhou has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Qiuliang Wang
Chinese Academy of Sciences
16 shared publications - Jianhua Liu
Chinese Academy of Sciences
14 shared publications - Lei Wang
Chinese Academy of Sciences
11 shared publications Zili Zhang
University of the Chinese Academy of Sciences, Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
8 shared publicationsKangshuai Wang
Chinese Academy of Sciences
7 shared publications- Xiaoyu Ji
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
6 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (8) , 4607607
The Adjustment of the Turn-to-Turn Contact Resistance of REBCO Tape by Stripe Shape Stainless-Steel Coating
In this paper, the stripe shape stainless-steel coating on the commercial REBCO tape was attempted to adjust the turn-to-turn contact resistance. The original plan is to use a stripe SS coating to create the space between the two REBCO tapes and maintain the path on the SS coating part, which can significantly increase the contact resistance by decreasing the contact area. In real conditions, the SS coating did not reach its goal but created alternative pathways of SS-SS contact and Cu-Cu contact, which can also partially adjust the contact resistance. It is believed that the contact resistance can be controlled in a larger range by changing the coating materials.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (8) , 4607607
The Adjustment of the Turn-to-Turn Contact Resistance of REBCO Tape by Stripe Shape Stainless-Steel Coating
In this paper, the stripe shape stainless-steel coating on the commercial REBCO tape was attempted to adjust the turn-to-turn contact resistance. The original plan is to use a stripe SS coating to create the space between the two REBCO tapes and maintain the path on the SS coating part, which can significantly increase the contact resistance by decreasing the contact area. In real conditions, the SS coating did not reach its goal but created alternative pathways of SS-SS contact and Cu-Cu contact, which can also partially adjust the contact resistance. It is believed that the contact resistance can be controlled in a larger range by changing the coating materials.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (8) , 4607512
Investigation on the REBCO-NbTi low Resistance Joint for the High Field Stability Superconducting Magnet
In this paper, we report an investigation of the REBCO-NbTi low-resistance joint for highly stable field superconducting magnets, such as NMR. The REBCO-NbTi joint used the most reliable engineering soldering method. The joint resistance at 4.2 K can be as low as 0.1 nΩ when the joint length reaches 1.5 m. When combined with the meter-length REBCO-REBCO joint that has a resistance of less than 0.1 nΩ, as reported before, it is confirmed that the current meter-length soldering of the REBCO-NbTi joint and the REBCO-REBCO joint can initially satisfy the magnetic field stability of 1×10-8/h using an LTS+HTS magnet design up to 1.2 GHz (28.2 T). It proved the feasibility of the soldering REBCO-NbTi joint for the high stable field magnet.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (8) , 4607512
Investigation on the REBCO-NbTi low Resistance Joint for the High Field Stability Superconducting Magnet
In this paper, we report an investigation of the REBCO-NbTi low-resistance joint for highly stable field superconducting magnets, such as NMR. The REBCO-NbTi joint used the most reliable engineering soldering method. The joint resistance at 4.2 K can be as low as 0.1 nΩ when the joint length reaches 1.5 m. When combined with the meter-length REBCO-REBCO joint that has a resistance of less than 0.1 nΩ, as reported before, it is confirmed that the current meter-length soldering of the REBCO-NbTi joint and the REBCO-REBCO joint can initially satisfy the magnetic field stability of 1×10-8/h using an LTS+HTS magnet design up to 1.2 GHz (28.2 T). It proved the feasibility of the soldering REBCO-NbTi joint for the high stable field magnet.
- 1 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39  (10) , 105038
An integrated 3D field circuit coupled model for comparative study of quench behavior in NI REBCO coil under 3D and 2D axisymmetric framework
Non-insulated (NI) high-temperature superconducting coils are widely used in various applications such as high-field and fusion magnets, rendering the precise evaluation of their thermal stability essential. Recently, 2D axisymmetric models are adopted by some researchers to simulate the minimum quench energy (MQE) and normal zone propagation velocity of circular NI coils in the event of whole-turn quench. However, the 2D axisymmetric model neglects the disparities of physical field variables in the circumferential direction, potentially resulting in inaccurate predictions. Therefore, this work develops a 3D quench model incorporating the screening currents of NI coils by coupling the 3D T – A formulation with the partial element equivalent circuit network. The entire quench model is integrated into a single COMSOL program, which avoids complex cross-platform interaction. Meanwhile, a 2D axisymmetric model is constructed based on existing voltage-driven T – A formulation. The above two models share identical parameters to facilitate a quantitative comparison of their simulation results for quench dynamics. To validate their effectiveness, the charging results of the two models are compared, showing good agreement. Moreover, due to the screening current effect, both models exhibit a transient increase in magnetic field during the initial stage of heating. However, even in the case of whole-turn quench, significant discrepancies remain in the quench propagation modes between the two models: the 2D axisymmetric model relies solely on thermal conduction and magnetic induction, failing to accurately characterize the current transfer mechanism observed in the 3D model. Further analysis indicates that the 2D axisymmetric model may overestimate the MQE under conditions of low coil contact resistivity. Nevertheless, the 2D axisymmetric model can be employed to rapidly estimate the approximate range of MQE in the 3D model. This paper provides valuable insights into the rational selection of different quench analysis models for NI coils.
- 1 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39  (10) , 105038
An integrated 3D field circuit coupled model for comparative study of quench behavior in NI REBCO coil under 3D and 2D axisymmetric framework
Non-insulated (NI) high-temperature superconducting coils are widely used in various applications such as high-field and fusion magnets, rendering the precise evaluation of their thermal stability essential. Recently, 2D axisymmetric models are adopted by some researchers to simulate the minimum quench energy (MQE) and normal zone propagation velocity of circular NI coils in the event of whole-turn quench. However, the 2D axisymmetric model neglects the disparities of physical field variables in the circumferential direction, potentially resulting in inaccurate predictions. Therefore, this work develops a 3D quench model incorporating the screening currents of NI coils by coupling the 3D T – A formulation with the partial element equivalent circuit network. The entire quench model is integrated into a single COMSOL program, which avoids complex cross-platform interaction. Meanwhile, a 2D axisymmetric model is constructed based on existing voltage-driven T – A formulation. The above two models share identical parameters to facilitate a quantitative comparison of their simulation results for quench dynamics. To validate their effectiveness, the charging results of the two models are compared, showing good agreement. Moreover, due to the screening current effect, both models exhibit a transient increase in magnetic field during the initial stage of heating. However, even in the case of whole-turn quench, significant discrepancies remain in the quench propagation modes between the two models: the 2D axisymmetric model relies solely on thermal conduction and magnetic induction, failing to accurately characterize the current transfer mechanism observed in the 3D model. Further analysis indicates that the 2D axisymmetric model may overestimate the MQE under conditions of low coil contact resistivity. Nevertheless, the 2D axisymmetric model can be employed to rapidly estimate the approximate range of MQE in the 3D model. This paper provides valuable insights into the rational selection of different quench analysis models for NI coils.
- 1 August 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39  (8) , 085034
Effect of non-uniform turn-to-turn resistance on quench behavior of nested NI/MI REBCO magnets under open-circuit fault
The vulnerability of REBCO insert magnets to extreme mechanical responses during open-circuit faults has caused severe failures in some high-field systems. This work studies the fault behaviors of a nested no-insulation/metal-insulation (NI/MI) REBCO insert in a 30 T magnet using the rotated anisotropic resistivity method. Experimentally calibrated characteristic turn-to-turn resistances of unshunted and InSn surface-shunted coils (4000 and 100 μ Ω·cm 2 ) are adopted in the simulation. Results of simulations under radially non-uniform turn-to-turn resistance configurations reveal that electromagnetically coupled quench propagation forces the low-resistance layer to protect the high-resistance layer at the cost of excessive current and stress, failing to reconcile flux compensation and mechanical load. Two complementary strategies are then proposed: an axial graded resistance scheme that synchronizes regional discharge time constants to suppress current amplification, and an external magnetic dam that provides passive flux compensation via co-wound superconducting tapes in the over-banding layer. These reduce peak stress by ∼27%, meeting long-term operational safety thresholds. These findings demonstrate that regulating the spatiotemporal distribution of flux change rate through resistance matching is an effective approach to suppress open-circuit fault damage in nested magnets, offering a theoretical basis for quench protection design in high-field nested REBCO magnets.
- 1 August 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39  (8) , 085034
Effect of non-uniform turn-to-turn resistance on quench behavior of nested NI/MI REBCO magnets under open-circuit fault
The vulnerability of REBCO insert magnets to extreme mechanical responses during open-circuit faults has caused severe failures in some high-field systems. This work studies the fault behaviors of a nested no-insulation/metal-insulation (NI/MI) REBCO insert in a 30 T magnet using the rotated anisotropic resistivity method. Experimentally calibrated characteristic turn-to-turn resistances of unshunted and InSn surface-shunted coils (4000 and 100 μ Ω·cm 2 ) are adopted in the simulation. Results of simulations under radially non-uniform turn-to-turn resistance configurations reveal that electromagnetically coupled quench propagation forces the low-resistance layer to protect the high-resistance layer at the cost of excessive current and stress, failing to reconcile flux compensation and mechanical load. Two complementary strategies are then proposed: an axial graded resistance scheme that synchronizes regional discharge time constants to suppress current amplification, and an external magnetic dam that provides passive flux compensation via co-wound superconducting tapes in the over-banding layer. These reduce peak stress by ∼27%, meeting long-term operational safety thresholds. These findings demonstrate that regulating the spatiotemporal distribution of flux change rate through resistance matching is an effective approach to suppress open-circuit fault damage in nested magnets, offering a theoretical basis for quench protection design in high-field nested REBCO magnets.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (2) , 1-13
Possible Overestimation of I c Value of REBCO Tapes Due to the Narrow Bridge Fabricated by Laser Etching During Transport Measurements
Etching a narrow bridge on REBa2Cu3O7-x (REBCO, RE = Rare Earth) tape is a widely applied procedure during transport measurements of critical current (Ic), aiming to mitigate significant Lorentz forces. However, the microbridge can influence the measurement accuracy, and understanding this influence is crucial because it can bias the extrapolation of Ic to the full tape width. In this article, we reveal that the microbridge could result in an overestimation when extrapolating the full-width Ic values from microbridge ones. We identified two primary sources of this overestimation by systematically comparing the directly measured full-width Ic values with those extrapolated from narrow bridges under varying temperatures, applied magnetic fields, and field orientations. The first source arises from inaccuracies in the assumed cross-sectional geometry and area of the narrow bridge. Specifically, assuming a rectangular cross-section when the actual geometry is trapezoidal leads to significant overestimations. The second factor is the nonuniform pinning effect across the thickness of the REBCO layer. Although this effect is negligible at low magnetic fields and higher temperatures, it becomes significant at lower temperatures, high magnetic fields, and when the field is nearly parallel to the tape surface. Based on these findings, we propose an improved procedure for transport measurements using narrow bridges to achieve more accurate determinations of Ic.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (2) , 1-13
Possible Overestimation of I c Value of REBCO Tapes Due to the Narrow Bridge Fabricated by Laser Etching During Transport Measurements
Etching a narrow bridge on REBa2Cu3O7-x (REBCO, RE = Rare Earth) tape is a widely applied procedure during transport measurements of critical current (Ic), aiming to mitigate significant Lorentz forces. However, the microbridge can influence the measurement accuracy, and understanding this influence is crucial because it can bias the extrapolation of Ic to the full tape width. In this article, we reveal that the microbridge could result in an overestimation when extrapolating the full-width Ic values from microbridge ones. We identified two primary sources of this overestimation by systematically comparing the directly measured full-width Ic values with those extrapolated from narrow bridges under varying temperatures, applied magnetic fields, and field orientations. The first source arises from inaccuracies in the assumed cross-sectional geometry and area of the narrow bridge. Specifically, assuming a rectangular cross-section when the actual geometry is trapezoidal leads to significant overestimations. The second factor is the nonuniform pinning effect across the thickness of the REBCO layer. Although this effect is negligible at low magnetic fields and higher temperatures, it becomes significant at lower temperatures, high magnetic fields, and when the field is nearly parallel to the tape surface. Based on these findings, we propose an improved procedure for transport measurements using narrow bridges to achieve more accurate determinations of Ic.
- 19 January 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39  (2)
Electromagnetic modeling of no-insulation REBCO coils based on T-A formulation: from 2D to 3D
The T-A formulation based on thin film approximation has been widely used in REBCO coated conductors and their various devices. Recently, its compatibility with electromagnetic modeling of no-insulation (NI) coils has attracted increasing attention. Although most electromagnetic simulations of NI coils have been addressed in 2D, the development of 3D models remains essential - for instance, to account for the circumferential non-uniformity of circular coils or to simulate non-circular configurations. In this study, by introducing the Coulomb gauge and a reduced nodal current conservation equation, we extend the electromagnetic modeling of NI REBCO coils based on T-A formulation from 2D axisymmetric scenarios to more general 3D helical frameworks, thereby highlight the electric potential characteristics. Furthermore, two 3D homogenized bulk models based on scaling equivalence of radial resistivity and concentricization of misaligned windings were proposed, and their applicability was also clarified. Comparative with the 2D circular NI coils shows that the 3D spiral model significantly improves the spatial resolution by incorporating actual current direction. The 3D homogenized bulk model achieves results consistent with the spiral model in terms of coil terminal voltage, charging delay, and power losses, while offering substantially enhanced computational efficiency. To demonstrate the practicality of the models, we further presented the simulation results for a 3D dual-wound NI coil with detailed spiral structure and a large-scale 3D homogenized racetrack NI coil with non-uniform radial resistivity. This work provides a new universal approach and tool for electromagnetic modeling of joints, irregular NI coils, and circular NI coils with circumferential non-uniformity.
- 19 January 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39  (2)
Electromagnetic modeling of no-insulation REBCO coils based on T-A formulation: from 2D to 3D
The T-A formulation based on thin film approximation has been widely used in REBCO coated conductors and their various devices. Recently, its compatibility with electromagnetic modeling of no-insulation (NI) coils has attracted increasing attention. Although most electromagnetic simulations of NI coils have been addressed in 2D, the development of 3D models remains essential - for instance, to account for the circumferential non-uniformity of circular coils or to simulate non-circular configurations. In this study, by introducing the Coulomb gauge and a reduced nodal current conservation equation, we extend the electromagnetic modeling of NI REBCO coils based on T-A formulation from 2D axisymmetric scenarios to more general 3D helical frameworks, thereby highlight the electric potential characteristics. Furthermore, two 3D homogenized bulk models based on scaling equivalence of radial resistivity and concentricization of misaligned windings were proposed, and their applicability was also clarified. Comparative with the 2D circular NI coils shows that the 3D spiral model significantly improves the spatial resolution by incorporating actual current direction. The 3D homogenized bulk model achieves results consistent with the spiral model in terms of coil terminal voltage, charging delay, and power losses, while offering substantially enhanced computational efficiency. To demonstrate the practicality of the models, we further presented the simulation results for a 3D dual-wound NI coil with detailed spiral structure and a large-scale 3D homogenized racetrack NI coil with non-uniform radial resistivity. This work provides a new universal approach and tool for electromagnetic modeling of joints, irregular NI coils, and circular NI coils with circumferential non-uniformity.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (2) , 1-12
Inversion of Equivalent Contact Resistivities of Parallel-Wound Metal-Insulation HTS Coil Based on Experimental Data and Multilevel Simulation
Equivalent contact resistivity is a key parameter that affects the dynamic process and overcurrent characteristic of the non-insulation (NI) high-temperature superconducting coil. Adding stainless steel material between turns of a parallel-wound NI coil results in the formation of various types of internal contact interfaces. Therefore, describing the shunt behavior of the coil, i.e., the parallel-wound metal-insulation (PWMI) coil, requires more than one equivalent contact resistivity, which makes it difficult to determine their specific values only through coil inductance and time constant. To handle this problem, we propose a method to acquire distinct equivalent contact resistivities of the PWMI coil. In this method, the equivalent contact resistivities are inverted based on the measured coil voltage or magnetic field. The bridge to connect the experimental data and equivalent contact resistivities is the streamlined field–circuit coupling model based on the T–A formulation, which can reflect the complex electromagnetic topology and the distribution of equivalent contact resistivities of the PWMI coil. After obtaining the measurement results, the least-squares method is used to optimize the equivalent contact resistivities until the simulation curve is sufficiently consistent with the experimental curve. In order to improve the efficiency of the optimization, we construct the lumped circuit model of the PWMI coil. Before the optimization process begins, the initial values of equivalent contact resistivities can be obtained based on this model, which can reduce the search scope of the optimization. The results of multiprocess testing indicate that using the equivalent contact resistivities obtained by the proposed method can effectively predict the transient behavior of the coil.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (2) , 1-12
Inversion of Equivalent Contact Resistivities of Parallel-Wound Metal-Insulation HTS Coil Based on Experimental Data and Multilevel Simulation
Equivalent contact resistivity is a key parameter that affects the dynamic process and overcurrent characteristic of the non-insulation (NI) high-temperature superconducting coil. Adding stainless steel material between turns of a parallel-wound NI coil results in the formation of various types of internal contact interfaces. Therefore, describing the shunt behavior of the coil, i.e., the parallel-wound metal-insulation (PWMI) coil, requires more than one equivalent contact resistivity, which makes it difficult to determine their specific values only through coil inductance and time constant. To handle this problem, we propose a method to acquire distinct equivalent contact resistivities of the PWMI coil. In this method, the equivalent contact resistivities are inverted based on the measured coil voltage or magnetic field. The bridge to connect the experimental data and equivalent contact resistivities is the streamlined field–circuit coupling model based on the T–A formulation, which can reflect the complex electromagnetic topology and the distribution of equivalent contact resistivities of the PWMI coil. After obtaining the measurement results, the least-squares method is used to optimize the equivalent contact resistivities until the simulation curve is sufficiently consistent with the experimental curve. In order to improve the efficiency of the optimization, we construct the lumped circuit model of the PWMI coil. Before the optimization process begins, the initial values of equivalent contact resistivities can be obtained based on this model, which can reduce the search scope of the optimization. The results of multiprocess testing indicate that using the equivalent contact resistivities obtained by the proposed method can effectively predict the transient behavior of the coil.
- 1 November 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38  (11) , 115003
Numerical and experimental study of screening current mitigation under shaking field in no-insulation coils
The screening current problem is one of the most critical challenges in high-temperature superconducting (HTS) coated conductors, severely degrading both the magnetic field magnitude and the stability of HTS inserts in high-field superconducting magnets. A promising strategy to mitigate screening current is the application of a shaking field perpendicular to the penetrating field. However, existing studies lack an effective computational model for the vortex shaking process and a comprehensive investigation into the unique characteristics of no-insulation (NI) coils under a shaking field. In this paper, a T-A formulation considering the coil thickness is used to simulate the electromagnetic behavior of NI coils during the shaking process. By combining simulations and experiments, the reduction of the screening current-induced field (SCIF) under varying coil parameters and operation conditions is investigated. The results indicate that the radial current has a dominant influence on the SCIF in NI coils with low contact resistivity. The rapid change in radial current induced by the shaking field leads to a sharp mitigation in the screening current within a short period, exhibiting a strong dependence on the shaking duration and coil’s contact resistivity. Moreover, this study demonstrates the effectiveness of the shaking field in accelerating radial current decline, and evaluates the additional AC losses induced by shaking field. These findings offer insights into the different mechanisms of the shaking field on SCIF reduction and radial current decline in NI coils, contributing to a better understanding of strategies for mitigating large screening current in REBCO magnets.
- 1 November 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38  (11) , 115003
Numerical and experimental study of screening current mitigation under shaking field in no-insulation coils
The screening current problem is one of the most critical challenges in high-temperature superconducting (HTS) coated conductors, severely degrading both the magnetic field magnitude and the stability of HTS inserts in high-field superconducting magnets. A promising strategy to mitigate screening current is the application of a shaking field perpendicular to the penetrating field. However, existing studies lack an effective computational model for the vortex shaking process and a comprehensive investigation into the unique characteristics of no-insulation (NI) coils under a shaking field. In this paper, a T-A formulation considering the coil thickness is used to simulate the electromagnetic behavior of NI coils during the shaking process. By combining simulations and experiments, the reduction of the screening current-induced field (SCIF) under varying coil parameters and operation conditions is investigated. The results indicate that the radial current has a dominant influence on the SCIF in NI coils with low contact resistivity. The rapid change in radial current induced by the shaking field leads to a sharp mitigation in the screening current within a short period, exhibiting a strong dependence on the shaking duration and coil’s contact resistivity. Moreover, this study demonstrates the effectiveness of the shaking field in accelerating radial current decline, and evaluates the additional AC losses induced by shaking field. These findings offer insights into the different mechanisms of the shaking field on SCIF reduction and radial current decline in NI coils, contributing to a better understanding of strategies for mitigating large screening current in REBCO magnets.
- 10 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (3) , 1-5
Study on Non-Planarity in Pancake Coils and its Influence on Magnetic Field
The manufacturing accuracy of high-temperature superconducting pancake coils is a key factor determining the magnetic field performance of high-field and high-homogeneity magnets such as NMR/MRI. This study first obtains the deformation angle of 36 sets of double pancake (DP) coils, in which the angle distribution of the upper half of each DP coil ranges from −3.2° to 5.2° and in the lower half ranges from −4.4° to 3.2°. Then, using nonparametric Monte Carlo method, combined with electromagnetic simulation and harmonic expansion to analyze 800 sets of magnetic field changes in magnets. The results indicate that non-planarity of DP coil reduces the central magnetic field which is 6.1% to 16.5% lower than the initial central magnetic field, meanwhile the peak-to-peak inhomogeneity typically deteriorates by 2 to 3 orders of magnitude compared to the initial state. This study is aim to quantify the non-planarity of DP coils, briefly analyze the possible causes of non-planarity, and deeply investigate the potential magnetic field effects, laying the foundation for further study on the fundamental causes of this deformation.
- 10 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (3) , 1-5
Study on Non-Planarity in Pancake Coils and its Influence on Magnetic Field
The manufacturing accuracy of high-temperature superconducting pancake coils is a key factor determining the magnetic field performance of high-field and high-homogeneity magnets such as NMR/MRI. This study first obtains the deformation angle of 36 sets of double pancake (DP) coils, in which the angle distribution of the upper half of each DP coil ranges from −3.2° to 5.2° and in the lower half ranges from −4.4° to 3.2°. Then, using nonparametric Monte Carlo method, combined with electromagnetic simulation and harmonic expansion to analyze 800 sets of magnetic field changes in magnets. The results indicate that non-planarity of DP coil reduces the central magnetic field which is 6.1% to 16.5% lower than the initial central magnetic field, meanwhile the peak-to-peak inhomogeneity typically deteriorates by 2 to 3 orders of magnitude compared to the initial state. This study is aim to quantify the non-planarity of DP coils, briefly analyze the possible causes of non-planarity, and deeply investigate the potential magnetic field effects, laying the foundation for further study on the fundamental causes of this deformation.
- Open Access
- 11 September 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138  (10)
Numerical analysis of electromagnetic behavior in D-shaped coils for toroidal field magnet
In the current emerging research of compact tokamak devices, it is important to study the electromagnetic response of D-shaped coils in the toroidal field (TF) magnet. In this paper, a numerical electromagnetic analysis of D-shaped coils for TF magnets in a fusion system is conducted, which focuses on no-insulation (NI) configuration. Utilizing a 3D finite element model with H-formulation, the electromagnetic behavior of the coil is investigated under varying charging rates, contact resistivity, and sudden discharge scenarios. The results reveal that NI coils exhibit significant charging delay effects due to radial current redistribution, with delay characteristics dependent on the charging rate and contact resistivity. AC loss analyses reveal that contact losses dominate at low contact resistance, while superconducting losses become negligible. The mutual inductance effects are also explored in nested D-shaped coil systems, showing that outer coil suddenly discharges induce transient perturbations in the internal coil, thereby threatening system stability. Furthermore, the electromagnetic characteristics of the complete TF magnet system are analyzed. These findings provide insights into optimizing TF magnet designs for compact tokamaks.
- 11 September 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138  (10)
Open AccessNumerical analysis of electromagnetic behavior in D-shaped coils for toroidal field magnet
In the current emerging research of compact tokamak devices, it is important to study the electromagnetic response of D-shaped coils in the toroidal field (TF) magnet. In this paper, a numerical electromagnetic analysis of D-shaped coils for TF magnets in a fusion system is conducted, which focuses on no-insulation (NI) configuration. Utilizing a 3D finite element model with H-formulation, the electromagnetic behavior of the coil is investigated under varying charging rates, contact resistivity, and sudden discharge scenarios. The results reveal that NI coils exhibit significant charging delay effects due to radial current redistribution, with delay characteristics dependent on the charging rate and contact resistivity. AC loss analyses reveal that contact losses dominate at low contact resistance, while superconducting losses become negligible. The mutual inductance effects are also explored in nested D-shaped coil systems, showing that outer coil suddenly discharges induce transient perturbations in the internal coil, thereby threatening system stability. Furthermore, the electromagnetic characteristics of the complete TF magnet system are analyzed. These findings provide insights into optimizing TF magnet designs for compact tokamaks.