NANeslihan Arhun

Neslihan Arhun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Neslihan Arhun has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Understanding Empathy in Patient‐Centered Dentistry: The Role of Emotional Intelligence and Psychosocial Factors

    by Sevgi Güngör, Leyla Kerimova‐Köse, Ruhsan Müdüroğlu‐Adıgüzel, Neslihan Arhun

    Objective: This study investigated the relationship between empathy and emotional intelligence (EI) among undergraduate dental students and explored the effects of demographic and psychosocial factors on empathy levels. Methods: A cross‐sectional survey was conducted among first‐ to fifth‐year dental students between May and June 2025. Data were collected using an electronic questionnaire comprising the Jefferson Scale of Physician Empathy‐Student Version (JSPE‐S) and the Schutte Emotional Intelligence Scale. Demographic and psychosocial variables included gender, academic year, daily screen time, medication use, negative dental experiences, pet ownership, co‐living with a sibling or grandparents, participation in social responsibility projects, and engagement in artistic activities. Statistical analyses included the Kolmogorov–Smirnov test for normality, Mann–Whitney U , Kruskal–Wallis with Dunn–Bonferroni post hoc tests, Spearman's rank correlation, and multiple linear regression ( p < 0.05). Results: Among 479 participants (response rate: 98%), a significant positive correlation was found between EI and empathy ( p < 0.001). Higher empathy was associated with female gender ( p = 0.008), participation or willingness to participate in social projects ( p = 0.014), and pet ownership ( p = 0.012). Higher EI was observed among students participating in social projects ( p < 0.001), owning pets ( p = 0.010), and engagement in artistic activities ( p = 0.020). Multiple regression analysis identified EI ( p < 0.001), social project participation ( p = 0.018), and female gender ( p = 0.044) as significant predictors of empathy. Conclusion: Empathy and EI are positively correlated. Female gender, social project participation, and elevated EI predict greater empathy. These findings emphasize the need for educational strategies that foster EI, empathy, and community engagement to promote compassionate, patient‐centered care.

  • Is the repair bond strength affected when substrate and repair composite are not of the same kind? A systematic review and meta-analysis

    by Leyla Kerimova Köse, Hatice Işık, Tan Fırat Eyüboğlu, Mutlu Özcan, Sevi Burçak Çehreli, Neslihan Arhun

    The goal in restorative dentistry is to perform lifelong restorations without sacrificing from healthy tooth tissues more than required [1–3]. Unfortunately, oral environment is an aggressive milie...


  • Open Access

    How Does Radiotherapy Affect the Adhesion of Universal Adhesive to Enamel and Dentin? A Qualitative and Quantitative Analysis?

    by Burcu Oglakci, Defne Burduroğlu, Ali Hikmet Eriş, Alpaslan Mayadağlı, Neslihan Arhun

    This study investigated the shear bond strength (SBS) of a universal adhesive to enamel/dentin; 1) that had undergone radiotherapy (RT) and 2) that were readily restored and had undergone RT. Enamel and dentin surfaces were obtained from 90 intact human molars. They were randomly divided into six groups according to the presence and timing of irradiation (RT0:no radiotherapy/control, RT1:RT before restoration, RT2:RT after restoration groups) and adhesive application modes (etch&rinse/ER, self-etch/SE)(n=15). A universal adhesive and resin composites were applied. The radiotherapy protocol was conducted with 60 Gy. The SBS test was subjected (1mm/min) and failure type analysis was performed. The resin-enamel/dentin interfaces were examined. Data were statistically analyzed. For enamel and dentin, the presence and timing of irradiation did not significantly influence the SBS values (p>0.05). For enamel, significantly higher SBS values were obtained using etch&rinse mode than self-etch mode (p<0.05). The predominant failure was mixed type. Loss of enamel prisms and obliterated irregular dentinal tubules were found for the radiotherapy-treated specimens. Resin tags were clearer in the irradiated enamel treated with ER than SE. Irradiation with different timings did not influence the bond strength to enamel and dentin, negatively. Irrespective of radiotherapy, the etch&rinse mode caused higher bond strength to enamel than self-etch mode.


  • Efficacy of multi-mode adhesive systems on dentin wettability and microtensile bond strength of resin composite

    by Neslihan Arhun, Derya Merve Halacoglu, Zümrüt Ceren Ozduman, Duygu Tuncer

    Purpose: To evaluate the wetting ability and the microtensile bond strength of adhesive systems in various depths of dentin. Materials and Method: 48 extracted human molars cut in half in buccolingual direction. Buccal and lingual surfaces were used to obtain deep (n = 48) and superficial (n = 48) dentin. Groups were divided into 4 subgroups: Self-etch (CSE), etch&rinse (SB), multi-mode self-etch (SAU) and multimode etch&rinse (EAU) adhesive systems. 3 consecutive contact-angle measurements were obtained: T0- 3 μl drop of distilled water on dentin; T1-Droplet of the adhesive; T2- Distilled water after polymerization of the adhesive. After composite build-ups, microtensile measurements were performed. Contact angle data were analysed with analysis of variance for repeated measures. Bond strength data were analyzed by repeated measures analysis of variance, comparisons were made according to the logarithmic values (p < 0.05). Results: The difference between groups was not significant regardless of dentin depth for all measurements (p < 0.05). All groups except CSE enhanced the wetting ability of the adhesive but reduced the wetting ability of distilled water after application of the adhesive (p < 0.05). Regarding adhesive systems, the groups showed no significant difference between bond strengths to various depths of dentin except SAU (p > 0.05); in SAU, bond strength to deep dentine were significantly higher than superficial dentin (p < 0.05). Regarding adhesives’ bond strength, CSE showed significantly greater values than the other groups (p < 0.05). Conclusion: The cavity depth does not affect the bonding ability for all adhesive systems; self-etch adhesive systems might be a better choice since different adhesives may influence the wetting ability and microtensile bond strength of the dentin substrates.


  • Clinical evaluation of microhybrid composites in noncarious cervical lesions: 24-month results

    by D Tuncer, C Çelik, K Yamanel, N Arhun

    Objective: To evaluate the clinical performance of two different microhybrid resin composites in noncarious cervical lesions (NCCLs) after 24 months. Subjects and Methods: Ninety-seven NCCLs were restored with either TPH Spectrum (n = 48) or Filtek Z250 (n = 49) using an etch-and-rinse adhesive in 20 patients. The restorations were clinically evaluated using modified United States Public Health Service criteria for retention, color match, marginal discoloration, marginal adaptation, surface texture, anatomic form, postoperative sensitivity, and secondary caries. The restorations were assessed 1 week after placement (baseline) and after 6, 12, and 24 months. Restoration survival rates were calculated using the Kaplan–Meier procedure estimator, and a log-rank test was used to compare the survival distributions (P < 0.05). Statistical analysis was undertaken using Pearson's Chi-square test and Fisher's exact test to assess differences among the restorative materials (P < 0.05). Cochran's Q-test was employed for evaluating differences in the same restorative material between recall periods. Results: The retention rates were 100% at 6 months, 89.6% and 91.8% at 12 months, and 85.4% and 89.8% at 24 months for TPH and Z250, respectively. TPH showed a statistically significant difference in marginal discoloration between the baseline and 24 months results (P < 0.05). Both TPH and Z250 showed statistically significant differences in marginal adaptation between the baseline and 24 months results (P < 0.05). Conclusion: Over the 24-month period, both microhybrid resin composites demonstrated acceptable clinical results in NCCLs.


  • Open Access

    Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments

    by Cigdem Celik, Sevi Burcak Cehreli, Neslihan Arhun

    Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000×). Mesial and distal 1/3 parts of the restorations were removed out leaving only middle part. One side of the cavity was finished with course diamond bur and the other was air-abraded with 50 μm Al2O3. They were randomly divided into four groups (n = 10) to receive: Group 1: Adper Single Bond 2; Group 2: All Bond 3; Group 3: ClearfilSE; Group 4: BeautiBond, before being repaired with the same resin composite (Filtek Z250). The specimens were re-thermocycled (1000×), sealed with nail varnish, stained with 0.5% basic fuchsin, sectioned mesiodistally and photographed digitally. The extent of dye penetration was measured by image analysis software (ImageJ) for both bur-finished and air-abraded surfaces at resin-tooth and resin-resin interfaces. The data were analyzed statistically. Results: BeautiBond exhibited the most microleakage at every site. Irrespective of adhesive and initial composite type, air-abrasion showed less microleakage except for BeautiBond. The type of initial repaired restorative material did not affect the microleakage. BeautiBond adhesive may not be preferred in resin composite repair in terms of microleakage prevention. Conclusions: Surface treatment with air-abrasion produced the lowest microleakage scores, independent of the adhesive systems and the pre-existing resin composite type. Pre-existing composite type does not affect the microleakage issue. All-in-one adhesive resin (BeautiBond) may not be preferred in resin composite repair in terms of microleakage prevention.


  • Open Access

    Clinical Evaluation of Resin-Based Composites in Posterior Restorations: A 3-Year Study

    by Çiğdem Çelik, Neslihan Arhun, Kivanc Yamanel

    Objectives: The aim of this study was to evaluate the clinical performance of a nanohybrid and a microhybrid composite in class I and II restorations after 3 years. Subjects and Methods: A total of 82 class I and class II restorations were performed in 31 patients (10 males and 21 females) using Grandio and QuiXfil with self-etch adhesives (Futurabond and Xeno III). The restorations were clinically evaluated by 2 operators 1 week after placement (baseline) and at 6 months and 1, 2, and 3 years using modified United States Public Health Service (USPHS) criteria. At the 3-year follow-up, 62 class I and class II cavities were reevaluated in 23 patients (7 males and 16 females). Statistical analysis was performed using Pearson's χ2 and Fisher's exact tests (p < 0.05). Results: At the 6-month follow-up, all restorations received Alfa scores with respect to each evaluation criterion. At the 1-year follow-up, 2 QuiXfil restorations had to be replaced and Grandio restorations started to deteriorate in terms of marginal adaptation. At the end of 2 years, 9 Grandio restorations showed significant deterioration of the surface properties, demonstrating Bravo scores. At the end of 3 years, no significant differences were observed regarding color match, marginal adaptation, secondary caries, marginal discoloration, and anatomic form loss between the evaluated materials in 25 class I and 37 class II restorations. At the 3-year follow-up, Grandio restorations had 21% Bravo scores and showed significant deterioration of the surface properties, which were still clinically acceptable according to USPHS criteria. Three QuiXfil and 1 Grandio restorations were replaced because of secondary caries and loss of retention. Conclusions: Both the nanohybrid (Grandio) and the microhybrid (QuiXfil) composites were clinically functional after 3 years.


  • Microtensile bond strength of composite-to-composite repair with different surface treatments and adhesive systems

    by Cigdem Celik, Burcak Sevi Cehreli, Bora Bagis, Neslihan Arhun

    Objectives: The purpose was to investigate the effect of different surface treatments and bonding agents on the repair bond strength of different resin-based restorative materials by microtensile bond strength (μTBS) testing protocol. Materials and Methods: 24 Grandio SO(VOCO) and 24 Filtek Z250(3 M) resin composite blocks were prepared. Half of the samples (N = 12) were diamond bur-roughened and the other half (N = 12) were sandblasted by 50 μm aluminum oxide particles. They were further divided into four sub-groups (n = 3) and received the following: Sub-Group1: Adper Single Bond2 (Etch&Rinse) (3 M); Sub-Group2: Clearfil SE (Self-etch) (Kuraray); Sub-Group3: Beauty Bond (HEMA-free all-in-one) (Shofu); Sub-Group4: All Bond3 (HEMA-free, hydrophobic, etch&rinse) (Bisco). The samples were repaired by Filtek Z250 to form a block. All of the resultant sub-groups combinations consisted of one of the composite type, surface treatment type, and adhesive systems. A total of 18 groups were prepared including 2 homogeneous blocks. They were thermocycled and μTBS measurements were performed. Data were statistically analyzed with Kruskall–Wallis and Mann–Whitney U tests. Results: The experimental regroups’ μTBS reached to 34.67–66.36% and 43.44–95.52% of the cohesive bond strength for Grandio SO and Z250, respectively. The pre-existing composite type is found to be statistically important. When the surface is bur-finished Grandio performed better; when air-abrasion is considered Z250 showed higher bond strength. All-in-one adhesive system produced the weakest bond strength at all parameters. Conclusion: It may be suggested that when the pre-existing composite is unknown, air-abrasion may be performed with etch&rinse or two-step self-etch adhesives.


  • Do Adhesive Systems Leave Resin Coats on the Surfaces of the Metal Matrix Bands? An Adhesive Remnant Characterization

    by Neslihan Arhun, Sevi Burcak Cehreli

    Neslihan Arhun, DDS, MSc, PhD/Sevi Burcak Cehreli, DDS, PhD: Reestablishing proximal contacts with composite resins may prove challenging since the applied adhesives may lead to resin coating that produces additional thickness. The aim of this study was to investigate the surface of metal matrix bands after application of adhesive systems and blowing or wiping off the adhesive before polymerization. Seventeen groups of matrix bands were prepared. The remnant particles were characterized by energy dispersive spectrum and scanning electron microscopy. Total etch and twostep self-etch adhesives did not leave any resin residues by wiping and blowing off. All-in-one adhesive revealed resin residues despite wiping off. Prime and Bond NT did not leave any remnant with compomer. Clinicians must be made aware of the consequences of possible adhesive remnants on matrix bands that may lead to a defective definitive restoration. The adhesive resin used for Class II restorations may leave resin coats on metal matrix bands after polymerization, resulting in additional thickness on the metal matrix bands and poor quality of the proximal surface of the definitive restoration when the adhesive system is incorporated in the restoration. (Int J Periodontics Restorative Dent 2013;33:e43?e50. doi: 10.11607/prd.1129)