YLYe Liu

Ye Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ye Liu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Performance Analysis of a Novel Cylindrical Nanocrystalline Shield for Enhancing Measurement Precision of Weak Magnetic Fields and Rotational Dynamics

    by Ye Liu, Haoying Pang, Yao Liu, Jiale Quan, Longyan Ma, Wenfeng Fan, Wei Quan

    With the rapid development of quantum technology, the application of high-precision atomic sensors is becoming increasingly widespread, such as in the detection and navigation of human cardiac, magnetic, and brain magnetic fields.The magnetic shielding system is the foundation for ensuring its high-precision measurement. The study employed the finite element method to quantitatively analyze the variations in magnetic shielding effectiveness for different hole sizes. The effect of nanocrystalline magnetic noise in weak magnetic and rotational measurements is also analyzed, and the use of a transfer function combined with Allan variance is proposed to quantitatively assess the effect of nanocrystalline magnetic noise on the long-term stability of rotational measurements. Furthermore, experimental measurements of the nanocrystalline shielding were conducted under static direct-current (DC). Finally, the K-Rb-4He magnetometer and K-Rb-21Ne were built to perform in-situ magnetic noise testing on the inner layer nanocrystalline magnetic shielding. The shielding effect, magnetic noise level, and long-term stability of inertial measurement were compared between nanocrystallines and ferrites as the innermost layer of magnetic shielding. The final results show that the nanocrystalline alloy as the innermost magnetic shield reduces the magnetic noise by 32.3% and the magnetic noise equivalent long-term rotational error by 45.9% at a smaller volume compared to ferrite.


  • A novel approach for enhancement of atomic spin polarization in spin-exchange relaxation-free gyroscopes based on a homogenized light field

    by Longyan Ma, Xiaohan Ge, Haoying Pang, Ye Liu, Jiale Quan, Hao Xia, Zhihong Wu, Lihong Duan, Xusheng Lei, Wei Quan

    Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.


  • Analysis and Suppression of the Pump Light Intensity Error in the K–Rb– 21 Ne Atomic Spin Comagnetometer

    by Jiale Quan, Ye Liu, Longyan Ma, Hao Xia, Wenfeng Fan, Haoying Pang, Zhihong Wu, Wei Quan

    As a novel quantum sensor utilizing atomic spin coupling mechanisms, spin-exchange relaxation-free (SERF) comagnetometers demonstrate promising applications in precision metrology such as magnetic field and rotation sensing. However, the ultra-high precision measurement capability exhibits vulnerability to multiple disturbance factors, with pump light intensity fluctuations emerging as a critical instability source that compromises operational reliability during prolonged measurements. In this paper, a model-driven paradigm for pump light intensity error suppression in SERF comagnetometers is proposed. The nonlinear dynamics are rigorously linearized via Taylor expansion within their valid range to construct a state-space model, ultimately deriving the pump light intensity frequency response model. The proposed methodology undergoes experimental validation on a K-Rb-21Ne comagnetometry platform, confirming the predictive capability for stability degradation mechanisms. Through theoretical analysis and experimental verification, this study reveals that magneto-optical non-orthogonality, which introduces a differential component in the light intensity transfer function, creates an approximate proportional relationship between the output signal and pump light intensity within the operating bandwidth. Light intensity noise is decomposed, and light intensity errors are quantitatively evaluated via the frequency response model. To address this critical issue affecting inertial measurement accuracy, a closed-loop control-based suppression method with optimized feedback gain is proposed. By dynamically adjusting the closed-loop feedback gain through real-time intensity monitoring, the intensity instability associated with optical pumping is suppressed from 0.56% to 0.14%, concomitant with a 2.8-fold improvement in the long-term stability of the SERF comagnetometer.


  • In-situ evaluation and efficient suppression of magneto-optical misalignment in K-Rb-21Ne comagnetometers

    by Longyan Ma, Haoying Pang, Xiaohan Ge, Ye Liu, Jiale Quan, Hao Xia, Zhihong Wu, Lihong Duan, Xusheng Lei, Wei Quan

    This study investigates the impact of magneto-optical misalignment on atomic spin responses in a spin-exchange relaxation-free (SERF) comagnetometer and proposes a method to measure and compensate for misalignment angles. By analyzing nuclear spin precession under varying bias magnetic field strengths, both the nuclear spin equivalent magnetic field (Bn) and the misalignment angle θ between the pump beam and the main magnetic field are extracted. To suppress the identified misalignment, a novel alignment technique based on periodic strong magnetic field pulses is introduced. This method enables rapid in-situ adjustment of the pump beam direction, thereby enhancing nuclear spin self-compensation and overall system performance. Experimental validation demonstrates that the proposed approach improves the suppression of transverse magnetic field interference, with a 43.2 % enhancement in magnetic response attenuation. Additionally, magneto-optical alignment optimization results in marked improvements in system stability and sensitivity: the Allan deviation at 100 s is reduced by 34 %, and the inertial measurement noise at 1 Hz decreases by 43.3 %, achieving a sensitivity of 3.56 × 10−6°/s/ √ Hz.


  • A Novel Co‐Magnetometer Based on Double‐Probe in Situ Decoupling of Magnetic Field and Inertia Rotation

    by Ye Liu, Wenfeng Fan, Yao Liu, Jiale Quan, Haoying Pang, Xin Wang, Longyan Ma, Wei Quan

    Magnetic noise and other magnetic system effects have been major factors hindering accurate measurements of exotic spin interactions. The atomic co‐magnetometer uses the different spin collisions of various substances to suppress magnetic field interference and magnetic noise. However, the current suppression of magnetic noise and magnetic field interference only involves passive shielding and parameter adjustment. Here, a novel in‐situ magnetic noise compensation mechanism is reported for an atomic co‐magnetometer, which arises from the difference in spin polarization behavior of two alkali metals in a mixed pumping. The magnetometer, which uses the potassium‐rubidium‐neon‐21 (K‐Rb‐) system, successfully decouples the magnetic fields and inertial rotations in situ. In addition, this new paramagnetic system can be used to simultaneously measure the magnetic field and inertial rotations, improving the stability of the measurement. These findings provide new possibilities for accurate measurements, including improving the stability of inertial rotations measurement and accessing unexplored parameter spaces.

  • Influence of Pumping Laser Intensity Uniformity on Hybrid Optically Pumped Comagnetometer in the SERF Regime

    by Longyan Ma, Ye Liu, Haoying Pang, Jiale Quan, Xiaohan Ge, Lihong Duan, Wei Quan

    The effect of pumping laser intensity uniformity (PLIU) on the operation of a hybrid optically pumped comagnetometer operating in the spin‐exchange relaxation‐free regime (SERF) regime is investigated in this paper. First, an analytical steady‐state output model for the comagnetometer with two alkali‐metal atoms and one noble‐gas atom is presented. By varying the diameter of the pumping laser beam to control the PLIU, 3D distribution models of the electron spin and nuclear spin polarization under different PLIU conditions are obtained. In the experiment, the effects of PLIU on multi‐parameter, low‐frequency magnetic‐noise suppression capability, and long‐term stability of the SERF comagnetometer are studied. The results indicate that within a certain range, increasing the diameter of the pumping laser beam improves the polarization uniformity of the atomic ensemble and reduces the light shift of the comagnetometer. As a result, both the low‐frequency magnetic noise suppression capability and the long‐term stability of the system increase. However, further reduction of the pumping laser diameter leads to a reversal of the system performance metrics, suggesting the presence of a tipping point. The research presented in this article is critical for advancing the efficient polarization study and hyperpolarization of SERF comagnetometers.


  • Open Access

    Integration of Semantic and Topological Structural Similarity Comparison for Entity Alignment without Pre-Training

    by Yao Liu, Ye Liu

    Entity alignment (EA) is a critical task in integrating diverse knowledge graph (KG) data and plays a central role in data-driven AI applications. Traditional EA approaches rely on entity embeddings, but their effectiveness is limited by scarce KG input data and representation learning techniques. Large language models have shown promise, but face challenges such as high hardware requirements, large model sizes and computational inefficiency, which limit their applicability. To overcome these limitations, we propose an entity-alignment model that compares the similarity between entities by capturing both semantic and topological information to enable the alignment of entities with high similarity. First, we analyze descriptive information to quantify semantic similarity, including individual features such as types and attributes. Then, for topological analysis, we introduce four conditions based on graph connectivity and structural patterns to determine subgraph similarity within three hops of the entity’s neighborhood, thereby improving accuracy. Finally, we integrate semantic and topological similarity using a weighted approach that considers dataset features. Our model requires no pre-training and is designed to be compact and generalizable to different datasets. Experimental results on four standard EA datasets validate the effectiveness of our proposed model.


  • Top Cited Papers

    A New Design Method for a Triaxial Magnetic Field Gradient Compensation System Based on Ferromagnetic Boundary

    by Zhihong Wu, Haoying Pang, Zhuo Wang, Wenfeng Fan, Feng Liu, Ye Liu, Wei Quan

    A new design method is proposed for a triaxial magnetic field gradient compensation system based on ferromagnetic boundary for atomic sensors. The target field method and the whale optimization algorithm are combined to design magnetic field coils thus transforming the complex analytical solution process into an intelligent optimization problem, while the boundary mirror method is introduced to decouple the coil from the magnetic shield. Magnetic field gradient coils are designed according to the coil design method and combined with the divergence and rotation theorems to form the triaxial gradients compensation system to suppress the magnetic field inhomogeneity in nine directions. The simulation and experimental results are compared with the results before and after compensation by using the box line diagram representing the statistics of the magnetic field deviation, in which the median value is reduced by 65.87% and 85.16%, the minimum by 99.66% and 77.76%, the 25 th quantile by 97.89% and 79.94%, and the 75th quantile by 91.52% and 85.17%, respectively.


  • Open Access

    Study on the Magnetic Noise Characteristics of Amorphous and Nanocrystalline Inner Magnetic Shield Layers of SERF Co-Magnetometer

    by Ye Liu, Hang Gao, Longyan Ma, Jiale Quan, Wenfeng Fan, Xueping Xu, Yang Fu, Lihong Duan, Wei Quan

    With the widespread use of magneto-sensitive elements, magnetic shields are an important part of electronic equipment, ultra-sensitive atomic sensors, and in basic physics experiments. Particularly in Spin-exchange relaxation-free (SERF) co-magnetometers, the magnetic shield is an important component for maintaining the SERF state. However, the inherent noise of magnetic shield materials is an important factor limiting the measurement sensitivity and accuracy of SERF co-magnetometers. In this paper, both amorphous and nanocrystalline materials were designed and applied as the innermost magnetic shield of an SERF co-magnetometer. Magnetic noise characteristics of different amorphous and nanocrystalline materials used as the internal magnetic shielding layer of the magnetic shielding system were analyzed. In addition, the effects on magnetic noise due to adding aluminum to amorphous and nanocrystalline materials were studied. The experimental results show that compared with an amorphous material, a nanocrystalline material as the inner magnetic shield layer can effectively reduce the magnetic noise and improve the sensitivity and precision of the rotation measurement. Nanocrystalline material is very promising for inner shield composition in SERF co-magnetometers. Furthermore, its ultra-thin structure and low cost have significant application value in the miniaturization of SERF co-magnetometers.


  • Suppression of Low-Frequency Magnetic Drift Based on Magnetic Field Sensitivity in K-Rb-21Ne Atomic Spin Comagnetometer

    by Ye Liu, Wenfeng Fan, Yang Fu, Haoying Pang, Hongyu Pei, Wei Quan

    A spin-exchange relaxation-free comagnetometer is a promising high-precision gyroscope as its inertial measurement sensitivity can rival that of existing technologies. The magnetic field error is one of the main factors that limits the long-term stability of the comagnetometer. The steady-state response and frequency response models of a K-Rb- 21 Ne comagnetometer are modified by considering the spin-exchange rate between the electron spins and the nuclear spins. The modified models are used to redefine the bias magnetic sensitivity of the K-Rb- 21 Ne comagnetometer and the suppression method of low-frequency magnetic field error is proposed. We demonstrate the magnetic drift suppression method proposed in the article by optimizing the cell temperature and pump laser power density. This study is helpful to improve the rotation measurement performance of the K-Rb- 21 Ne comagnetometer.