Jiale Quan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiale Quan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Haoying Pang
Beihang University
10 shared publications - Longyan Ma
Beihang University
9 shared publications - Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
8 shared publications - Hao Xia
School of Instrumentation and Optoelectronic Engineering Beihang University Beijing China
6 shared publications - Wenfeng Fan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
6 shared publications - Ye Liu
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
6 shared publications
Latest Publications
- 22 October 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (42) , 425106
Design of a novel low-magnetic and Singularity-free electric heater for atomic Co-magnetometers
To address the challenges of thermomagnetic coupling during the heating process of Spin-Exchange Relaxation-Free atomic co-magnetometers (ACMs), this paper proposes a novel design methodology for a low-magnetic, Singularity-free electric heater. Based on the physical mechanism of suppressing magnetic field aggregation via an Singularity-free rounded-rectangle configuration, a magnetic field model with adaptive weights is developed. This model effectively resolves the issues of insufficient magnetic constraint capability and low modeling precision in complex systems. Furthermore, an Adaptive Hybrid-Information Differential Evolution Algorithm (AHDE) is introduced. By integrating a hybrid-information-driven mechanism with dynamic weights, the AHDE achieves precise optimization of the heater’s design parameters. Experimental results demonstrate that, under identical heating power, the magnetic suppression capability of the new heater structure is enhanced by 51.6% and 67.1%, respectively, compared to conventional designs. Concurrently, the sensitivity of the ACM is improved by 15.4% and 20.5%. These results prove that the Singularity-free electric heater effectively reduces and suppresses magnetic field generation, achieving an optimal balance between heating efficiency and magnetic interference mitigation.
- 22 October 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (42) , 425106
Design of a novel low-magnetic and Singularity-free electric heater for atomic Co-magnetometers
To address the challenges of thermomagnetic coupling during the heating process of Spin-Exchange Relaxation-Free atomic co-magnetometers (ACMs), this paper proposes a novel design methodology for a low-magnetic, Singularity-free electric heater. Based on the physical mechanism of suppressing magnetic field aggregation via an Singularity-free rounded-rectangle configuration, a magnetic field model with adaptive weights is developed. This model effectively resolves the issues of insufficient magnetic constraint capability and low modeling precision in complex systems. Furthermore, an Adaptive Hybrid-Information Differential Evolution Algorithm (AHDE) is introduced. By integrating a hybrid-information-driven mechanism with dynamic weights, the AHDE achieves precise optimization of the heater’s design parameters. Experimental results demonstrate that, under identical heating power, the magnetic suppression capability of the new heater structure is enhanced by 51.6% and 67.1%, respectively, compared to conventional designs. Concurrently, the sensitivity of the ACM is improved by 15.4% and 20.5%. These results prove that the Singularity-free electric heater effectively reduces and suppresses magnetic field generation, achieving an optimal balance between heating efficiency and magnetic interference mitigation.
- 26 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (34) , 345006
Hybrid pumping with dual detection: a novel comagnetometer for dual-axis magnetic field and rotation measurement
Quantum sensing has demonstrated exceptional potential in magnetic field and inertial rotation measurements due to its ultra-high sensitivity. Among various implementations, the spin-exchange relaxation-free comagnetometer, as atomic spin sensor, exhibits remarkable sensitivity and strong potential for miniaturization and integration. However, the low-frequency performance of such comagnetometers is fundamentally limited by intrinsic noise due to the coupling between magnetic field ( B ) and inertial rotation signals ( Ω ). In this paper, a novel dual spin-polarization detection scheme for a hybrid-pumping comagnetometer is proposed. By introducing simultaneous detection of two electron spin polarizations combined with longitudinal magnetic field modulation and demodulation, our approach enables decoupling and synchronous measurement of B and Ω . The proposed scheme is experimentally validated on a K–Rb- 21 Ne comagnetometer platform. Experimental results show that the two electron species demonstrate inconsistent behaviors in the self-compensation effect, with their respective self-compensation points occurring at different operating conditions. Finally, by individually calibrating the dual spin-polarization detection outputs, real-time in situ measurements of dual-axis magnetic fields and inertial rotation are achieved, effectively addressing the crosstalk issue between magnetic and inertial signals.
- 26 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (34) , 345006
Hybrid pumping with dual detection: a novel comagnetometer for dual-axis magnetic field and rotation measurement
Quantum sensing has demonstrated exceptional potential in magnetic field and inertial rotation measurements due to its ultra-high sensitivity. Among various implementations, the spin-exchange relaxation-free comagnetometer, as atomic spin sensor, exhibits remarkable sensitivity and strong potential for miniaturization and integration. However, the low-frequency performance of such comagnetometers is fundamentally limited by intrinsic noise due to the coupling between magnetic field ( B ) and inertial rotation signals ( Ω ). In this paper, a novel dual spin-polarization detection scheme for a hybrid-pumping comagnetometer is proposed. By introducing simultaneous detection of two electron spin polarizations combined with longitudinal magnetic field modulation and demodulation, our approach enables decoupling and synchronous measurement of B and Ω . The proposed scheme is experimentally validated on a K–Rb- 21 Ne comagnetometer platform. Experimental results show that the two electron species demonstrate inconsistent behaviors in the self-compensation effect, with their respective self-compensation points occurring at different operating conditions. Finally, by individually calibrating the dual spin-polarization detection outputs, real-time in situ measurements of dual-axis magnetic fields and inertial rotation are achieved, effectively addressing the crosstalk issue between magnetic and inertial signals.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Coating-Enabled Buffer-Gas-Free Vapor Cell: A New Sensor Architecture for Single-Beam SERF Magnetometers
Alkali metal vapor cells are fundamental components in quantum sensors, and their relaxation characteristics critically influence both sensitivity and system stability. In Spin-Exchange Relaxation-Free (SERF) atomic magnetometers, although spin-exchange collisions are effectively suppressed, wall-collision-induced relaxation remains the primary limiting factor. A coating-enabled buffer-gas-free vapor cell (CBF-VC) is proposed as a novel sensor unit, realized through multilayer octadecyltrichlorosilane (OTS) selfassembled molecular coatings. The CBF-VC is integrated into a single-beam SERF atomic magnetometer, and experimental validation is conducted. The results indicate a significant extension of the wall collision relaxation time from 40.19 ms. This extended relaxation time directly enhances the magnetometer sensitivity by 48%, confirming the feasibility of CBF-VCs as a measurement-oriented vapor cell architecture. The findings demonstrate not only the effectiveness of anti-relaxation coatings, but also a new instrumentation pathway for advancing next-generation quantum sensing.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Coating-Enabled Buffer-Gas-Free Vapor Cell: A New Sensor Architecture for Single-Beam SERF Magnetometers
Alkali metal vapor cells are fundamental components in quantum sensors, and their relaxation characteristics critically influence both sensitivity and system stability. In Spin-Exchange Relaxation-Free (SERF) atomic magnetometers, although spin-exchange collisions are effectively suppressed, wall-collision-induced relaxation remains the primary limiting factor. A coating-enabled buffer-gas-free vapor cell (CBF-VC) is proposed as a novel sensor unit, realized through multilayer octadecyltrichlorosilane (OTS) selfassembled molecular coatings. The CBF-VC is integrated into a single-beam SERF atomic magnetometer, and experimental validation is conducted. The results indicate a significant extension of the wall collision relaxation time from 40.19 ms. This extended relaxation time directly enhances the magnetometer sensitivity by 48%, confirming the feasibility of CBF-VCs as a measurement-oriented vapor cell architecture. The findings demonstrate not only the effectiveness of anti-relaxation coatings, but also a new instrumentation pathway for advancing next-generation quantum sensing.
- Top Cited Papers
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
Performance Analysis of a Novel Cylindrical Nanocrystalline Shield for Enhancing Measurement Precision of Weak Magnetic Fields and Rotational Dynamics
With the rapid development of quantum technology, the application of high-precision atomic sensors is becoming increasingly widespread, such as in the detection and navigation of human cardiac, magnetic, and brain magnetic fields.The magnetic shielding system is the foundation for ensuring its high-precision measurement. The study employed the finite element method to quantitatively analyze the variations in magnetic shielding effectiveness for different hole sizes. The effect of nanocrystalline magnetic noise in weak magnetic and rotational measurements is also analyzed, and the use of a transfer function combined with Allan variance is proposed to quantitatively assess the effect of nanocrystalline magnetic noise on the long-term stability of rotational measurements. Furthermore, experimental measurements of the nanocrystalline shielding were conducted under static direct-current (DC). Finally, the K-Rb-4He magnetometer and K-Rb-21Ne were built to perform in-situ magnetic noise testing on the inner layer nanocrystalline magnetic shielding. The shielding effect, magnetic noise level, and long-term stability of inertial measurement were compared between nanocrystallines and ferrites as the innermost layer of magnetic shielding. The final results show that the nanocrystalline alloy as the innermost magnetic shield reduces the magnetic noise by 32.3% and the magnetic noise equivalent long-term rotational error by 45.9% at a smaller volume compared to ferrite.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
Top Cited PapersPerformance Analysis of a Novel Cylindrical Nanocrystalline Shield for Enhancing Measurement Precision of Weak Magnetic Fields and Rotational Dynamics
With the rapid development of quantum technology, the application of high-precision atomic sensors is becoming increasingly widespread, such as in the detection and navigation of human cardiac, magnetic, and brain magnetic fields.The magnetic shielding system is the foundation for ensuring its high-precision measurement. The study employed the finite element method to quantitatively analyze the variations in magnetic shielding effectiveness for different hole sizes. The effect of nanocrystalline magnetic noise in weak magnetic and rotational measurements is also analyzed, and the use of a transfer function combined with Allan variance is proposed to quantitatively assess the effect of nanocrystalline magnetic noise on the long-term stability of rotational measurements. Furthermore, experimental measurements of the nanocrystalline shielding were conducted under static direct-current (DC). Finally, the K-Rb-4He magnetometer and K-Rb-21Ne were built to perform in-situ magnetic noise testing on the inner layer nanocrystalline magnetic shielding. The shielding effect, magnetic noise level, and long-term stability of inertial measurement were compared between nanocrystallines and ferrites as the innermost layer of magnetic shielding. The final results show that the nanocrystalline alloy as the innermost magnetic shield reduces the magnetic noise by 32.3% and the magnetic noise equivalent long-term rotational error by 45.9% at a smaller volume compared to ferrite.
- Top Cited Papers
- 23 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Synchronous Measurement of Magnetic Field and Rotation Using Longitudinal Magnetic Field Modulation in Atomic Spin Comagnetometers
Quantum sensors renowned for their ultra-high measurement sensitivity, have emerged as a promising technology for precision measurements in fields such as inertia and magnetic field, attracting significant research interest in recent years. However, atomic spin comagnetometers operating in the spin-exchange relaxation-free (SERF) regime are susceptible to low-frequency noise, with the inherent coupling between magnetic field and inertial rotation signals severely limiting measurement stability. To address this issue, this study investigates the signal generation and decoupling mechanisms, and proposes a dual-parameter synchronous measurement method based on longitudinal magnetic field modulation. Theoretical and experimental analyses reveal that the first-harmonic component exhibits a self-compensation effect (SCE) similar to the DC signal, enabling the construction of a dual-input-dual-output decoupling system. The proposed scheme is experimentally validated on a K-Rb-21Ne SERF comagnetometer platform, achieving simultaneous measurement of magnetic field and rotation under steady-state conditions, with a magnetic sensitivity of 2.03 pT= p/√ Hz and an inertial rotation measurement sensitivity of 2.41 ×10–5 °/s/√Hz.
- 23 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Top Cited PapersSynchronous Measurement of Magnetic Field and Rotation Using Longitudinal Magnetic Field Modulation in Atomic Spin Comagnetometers
Quantum sensors renowned for their ultra-high measurement sensitivity, have emerged as a promising technology for precision measurements in fields such as inertia and magnetic field, attracting significant research interest in recent years. However, atomic spin comagnetometers operating in the spin-exchange relaxation-free (SERF) regime are susceptible to low-frequency noise, with the inherent coupling between magnetic field and inertial rotation signals severely limiting measurement stability. To address this issue, this study investigates the signal generation and decoupling mechanisms, and proposes a dual-parameter synchronous measurement method based on longitudinal magnetic field modulation. Theoretical and experimental analyses reveal that the first-harmonic component exhibits a self-compensation effect (SCE) similar to the DC signal, enabling the construction of a dual-input-dual-output decoupling system. The proposed scheme is experimentally validated on a K-Rb-21Ne SERF comagnetometer platform, achieving simultaneous measurement of magnetic field and rotation under steady-state conditions, with a magnetic sensitivity of 2.03 pT= p/√ Hz and an inertial rotation measurement sensitivity of 2.41 ×10–5 °/s/√Hz.
- 4 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (12) , 125101
A novel approach for enhancement of atomic spin polarization in spin-exchange relaxation-free gyroscopes based on a homogenized light field
Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.
- 4 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (12) , 125101
A novel approach for enhancement of atomic spin polarization in spin-exchange relaxation-free gyroscopes based on a homogenized light field
Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Analysis and Suppression of the Pump Light Intensity Error in the K–Rb– 21 Ne Atomic Spin Comagnetometer
As a novel quantum sensor utilizing atomic spin coupling mechanisms, spin-exchange relaxation-free (SERF) comagnetometers demonstrate promising applications in precision metrology such as magnetic field and rotation sensing. However, the ultra-high precision measurement capability exhibits vulnerability to multiple disturbance factors, with pump light intensity fluctuations emerging as a critical instability source that compromises operational reliability during prolonged measurements. In this paper, a model-driven paradigm for pump light intensity error suppression in SERF comagnetometers is proposed. The nonlinear dynamics are rigorously linearized via Taylor expansion within their valid range to construct a state-space model, ultimately deriving the pump light intensity frequency response model. The proposed methodology undergoes experimental validation on a K-Rb-21Ne comagnetometry platform, confirming the predictive capability for stability degradation mechanisms. Through theoretical analysis and experimental verification, this study reveals that magneto-optical non-orthogonality, which introduces a differential component in the light intensity transfer function, creates an approximate proportional relationship between the output signal and pump light intensity within the operating bandwidth. Light intensity noise is decomposed, and light intensity errors are quantitatively evaluated via the frequency response model. To address this critical issue affecting inertial measurement accuracy, a closed-loop control-based suppression method with optimized feedback gain is proposed. By dynamically adjusting the closed-loop feedback gain through real-time intensity monitoring, the intensity instability associated with optical pumping is suppressed from 0.56% to 0.14%, concomitant with a 2.8-fold improvement in the long-term stability of the SERF comagnetometer.
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Analysis and Suppression of the Pump Light Intensity Error in the K–Rb– 21 Ne Atomic Spin Comagnetometer
As a novel quantum sensor utilizing atomic spin coupling mechanisms, spin-exchange relaxation-free (SERF) comagnetometers demonstrate promising applications in precision metrology such as magnetic field and rotation sensing. However, the ultra-high precision measurement capability exhibits vulnerability to multiple disturbance factors, with pump light intensity fluctuations emerging as a critical instability source that compromises operational reliability during prolonged measurements. In this paper, a model-driven paradigm for pump light intensity error suppression in SERF comagnetometers is proposed. The nonlinear dynamics are rigorously linearized via Taylor expansion within their valid range to construct a state-space model, ultimately deriving the pump light intensity frequency response model. The proposed methodology undergoes experimental validation on a K-Rb-21Ne comagnetometry platform, confirming the predictive capability for stability degradation mechanisms. Through theoretical analysis and experimental verification, this study reveals that magneto-optical non-orthogonality, which introduces a differential component in the light intensity transfer function, creates an approximate proportional relationship between the output signal and pump light intensity within the operating bandwidth. Light intensity noise is decomposed, and light intensity errors are quantitatively evaluated via the frequency response model. To address this critical issue affecting inertial measurement accuracy, a closed-loop control-based suppression method with optimized feedback gain is proposed. By dynamically adjusting the closed-loop feedback gain through real-time intensity monitoring, the intensity instability associated with optical pumping is suppressed from 0.56% to 0.14%, concomitant with a 2.8-fold improvement in the long-term stability of the SERF comagnetometer.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
In-situ evaluation and efficient suppression of magneto-optical misalignment in K-Rb-21Ne comagnetometers
This study investigates the impact of magneto-optical misalignment on atomic spin responses in a spin-exchange relaxation-free (SERF) comagnetometer and proposes a method to measure and compensate for misalignment angles. By analyzing nuclear spin precession under varying bias magnetic field strengths, both the nuclear spin equivalent magnetic field (Bn) and the misalignment angle θ between the pump beam and the main magnetic field are extracted. To suppress the identified misalignment, a novel alignment technique based on periodic strong magnetic field pulses is introduced. This method enables rapid in-situ adjustment of the pump beam direction, thereby enhancing nuclear spin self-compensation and overall system performance. Experimental validation demonstrates that the proposed approach improves the suppression of transverse magnetic field interference, with a 43.2 % enhancement in magnetic response attenuation. Additionally, magneto-optical alignment optimization results in marked improvements in system stability and sensitivity: the Allan deviation at 100 s is reduced by 34 %, and the inertial measurement noise at 1 Hz decreases by 43.3 %, achieving a sensitivity of 3.56 × 10−6°/s/ √ Hz.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
In-situ evaluation and efficient suppression of magneto-optical misalignment in K-Rb-21Ne comagnetometers
This study investigates the impact of magneto-optical misalignment on atomic spin responses in a spin-exchange relaxation-free (SERF) comagnetometer and proposes a method to measure and compensate for misalignment angles. By analyzing nuclear spin precession under varying bias magnetic field strengths, both the nuclear spin equivalent magnetic field (Bn) and the misalignment angle θ between the pump beam and the main magnetic field are extracted. To suppress the identified misalignment, a novel alignment technique based on periodic strong magnetic field pulses is introduced. This method enables rapid in-situ adjustment of the pump beam direction, thereby enhancing nuclear spin self-compensation and overall system performance. Experimental validation demonstrates that the proposed approach improves the suppression of transverse magnetic field interference, with a 43.2 % enhancement in magnetic response attenuation. Additionally, magneto-optical alignment optimization results in marked improvements in system stability and sensitivity: the Allan deviation at 100 s is reduced by 34 %, and the inertial measurement noise at 1 Hz decreases by 43.3 %, achieving a sensitivity of 3.56 × 10−6°/s/ √ Hz.
- 4 March 2025
- Published by Elsevier in Measurement
- Vol. 250, 117123
Decoupling measurement and closed-loop suppression of transverse magnetic field drift in a modulated double-cell atomic comagnetometer
- 4 March 2025
- Published by Elsevier in Measurement
- Vol. 250, 117123
Decoupling measurement and closed-loop suppression of transverse magnetic field drift in a modulated double-cell atomic comagnetometer