HBH. J. Marcel ter Brake

H. J. Marcel ter Brake

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


H. J. Marcel ter Brake has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The payload of the Lunar Gravitational-wave Antenna

    by J. V. van Heijningen, H. J. M. ter Brake, O. Gerberding, S. Chalathadka Subrahmanya, J. Harms, X. Bian, A. Gatti, M. Zeoli, A. Bertolini, C. Collette, et al.

    The toolbox to study the Universe grew on 14 September 2015 when the LIGO–Virgo collaboration heard a signal from two colliding black holes between 30 and 250 Hz. Since then, many more gravitational waves have been detected as detectors continue to increase sensitivity. However, the current and future interferometric detectors will never be able to detect gravitational waves below a few Hz due to oceanic activity on Earth. An interferometric space mission, the laser interferometer space antenna, will operate between 1 mHz and 0.1 Hz, leaving a gap in the decihertz band. To detect gravitational-wave signals also between 0.1 and 1 Hz, the Lunar Gravitational-wave Antenna will use an array of seismic stations. The seismic array will be deployed in a permanently shadowed crater on the lunar south pole, which provides stable ambient temperatures below 40 K. A cryogenic superconducting inertial sensor is under development that aims for fm/√Hz sensitivity or better down to several hundred mHz, and thermal noise limited below that value. Given the 106 m size of the Moon, strain sensitivities below 10−20 1/√Hz can be achieved. The additional cooling is proposed depending on the used superconductor technology. The inertial sensors in the seismic stations aim to make a differential measurement between the elastic response of the Moon and the inertial sensor proof-mass motion induced by gravitational waves. Here, we describe the current state of research toward the inertial sensor, its applications, and additional auxiliary technologies in the payload of the lunar gravitational-wave detection mission.


  • Open Access

    Thermal and electrical design of superconducting demonstrator for magnetic density separation

    by J J Kosse, W A J Wessel, C Zhou, M Dhallé, G Tomás, H J G Krooshoop, H J M ter Brake, H H J Ten Kate

    In this paper the focus is on thermal and electrical design aspects of a NbTi-based demonstrator magnet for magnetic density separation (MDS) that is being constructed at the University of Twente. MDS is a recycling technology that allows the separation of non-magnetic particles based on their mass density, using a vertical magnetic field gradient and a ferrofluid. To minimize the distance between the planar array of racetrack coils and the ferrofluid bath, the system is conduction-cooled. First the thermal design is presented, which shows that the coils can operate below 4.5 K with sufficient margin using a single cryocooler. High-purity aluminium heat drains enable a low thermal gradient across the cold mass. The current path is introduced, as well as the adopted protection scheme. The magnet’s stored energy can safely be dumped in the coils. Diodes are placed (anti-)parallel to the coils in the cold to prevent high terminal voltages. In the case of a quench in the superconducting part of the current leads or an external anomaly, a switch is opened and the current is forced through a resistor in series with the diodes, causing a deliberate transition of the coils to the normal state and thus a fast ramp-down.


  • Open Access

    Mechanical design of a superconducting demonstrator for magnetic density separation

    by J J Kosse, W A J Wessel, C Zhou, M Dhallé, G Tomás, H J G Krooshoop, H J M ter Brake, H H J Ten Kate

    The focus of this paper is on the mechanical design of a NbTi-based demonstrator magnet for magnetic density separation (MDS) that is being constructed at the University of Twente. MDS is a new recycling technology that allows the separation of non-magnetic particles based on their mass density, using a vertical magnetic field gradient and a ferrofluid. The unique mechanical design challenge for this type of magnet is the desired minimization of the distance between a sim1 m2 planar array of cryogenic racetrack coils and the ambient-temperature ferrofluid bath. The optimization of the magnet geometry results in a distance between the coils and ferrofluid of 50 mm. This is made possible by opting for conduction-cooling, for the inclusion of room-temperature rods that pass through the cold mass to support the cryostat, and for the geometry of the cassette that reacts to the Lorentz force.


  • Open Access

    Heat-triggered two-phase flow maldistribution in a micromachined cryogenic cooler

    by H.S. Cao, S. Vanapalli, H.J. Holland, C.H. Vermeer, H.J.M. ter Brake


  • Open Access

    Long-life micro vacuum chamber for a micromachined cryogenic cooler

    by Haishan Cao, Cristian H. Vermeer, Srinivas Vanapalli, Harry J. Holland, H. J. Marcel ter Brake

    Micromachined cryogenic coolers can be used for cooling small electronic devices to improve their performance. However, for reaching cryogenic temperatures, they require a very good thermal insulation from the warm environment. This is established by a vacuum space that for adequate insulation has to be maintained at a pressure of 0.01 Pa or lower. In this paper, the challenge of maintaining a vacuum chamber with a volume of 3.6 × 10−5 m3 and an inner wall area of 8.1 × 10−3 m2 at a pressure no higher than 0.01 Pa for five years is theoretically analyzed. The possible sources of gas, the mechanisms by which these gases enter the vacuum space and their effects on the pressure in the vacuum chamber are discussed. In a long-duration experiment with four stainless steel chambers of the above dimensions and equipped with a chemical getter, the vacuum pressures were monitored for a period of two years. In that period, the measured pressure increase stayed within 0.01 Pa. This study can be used to guide the design of long-lifetime micro vacuum chambers that operate without continuous mechanical pumping.