Cristian H. Vermeer
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cristian H. Vermeer has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- H. J. Marcel ter Brake
Faculty of Science and Technology, University of Twente 2 , 7522 NB Enschede, The Netherlands
2 shared publications - Haishan Cao
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Energy and Power Engineering, Tsinghua University, Beijing, China
2 shared publications - Srinivas Vanapalli
University of Twente
2 shared publications A H Tolboom
Univ Twente, POB 217, NL-7500 AE Enschede, Netherlands
1 shared publication- A. Xhahi1 shared publication
- Arend Nijhuis
University of Twente, Energy, Materials and Systems, Faculty of Science and Technology, Enschede 7500 AE, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 15 April 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 246
Multiphysics modeling of sorption compressors: A FEM-based thermo-adsorption framework
- 15 April 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 246
Open AccessMultiphysics modeling of sorption compressors: A FEM-based thermo-adsorption framework
- Open Access
- 7 March 2023
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 36 (4) , 045018
Predictable and robust performance of a Bi-2223 superconducting coil for compact isochronous cyclotrons
The development of ever smaller medical particle accelerators is motivated by a desire to make proton therapy accessible to more patients. Reducing the footprint of particle accelerators and subsequently proton therapy facilities allows for cheaper and broader usage of proton therapy. By employing superconducting technologies for field shaping, the size of particle accelerators can be reduced further below what is possible with saturated iron. This article discusses experiments on a first-of-its-kind double pancake (DP), and an assembly of six DP coils, designed to be used as a so-called ‘flutter coil’ for a compact isochronous cyclotron for proton therapy, fabricated from high-temperature superconducting (HTS) Bi 2 − x Pb x Sr2Ca2Cu3O y (Bi-2223) tape. The coils were mounted under pre-stress within a stainless-steel structure to maintain mechanical stability during the experiments. The critical current as a function of the temperature of both coils was measured in a conduction-cooled setup. A model describing the coils, based on tape data, was created and revealed that the measurements were in excellent agreement with the predictions. Additional experiments were performed to study the quench and thermal runaway behaviour of the HTS coils, determining whether such coils can be protected against fault scenarios, using realistic quench-detection levels and discharge extraction-rates. These experiments demonstrate that the coils are very robust and can be well protected against quenches and thermal-runaway events using common quench-protection measures with realistic parameters.
- 7 March 2023
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 36 (4) , 045018
Open AccessPredictable and robust performance of a Bi-2223 superconducting coil for compact isochronous cyclotrons
The development of ever smaller medical particle accelerators is motivated by a desire to make proton therapy accessible to more patients. Reducing the footprint of particle accelerators and subsequently proton therapy facilities allows for cheaper and broader usage of proton therapy. By employing superconducting technologies for field shaping, the size of particle accelerators can be reduced further below what is possible with saturated iron. This article discusses experiments on a first-of-its-kind double pancake (DP), and an assembly of six DP coils, designed to be used as a so-called ‘flutter coil’ for a compact isochronous cyclotron for proton therapy, fabricated from high-temperature superconducting (HTS) Bi 2 − x Pb x Sr2Ca2Cu3O y (Bi-2223) tape. The coils were mounted under pre-stress within a stainless-steel structure to maintain mechanical stability during the experiments. The critical current as a function of the temperature of both coils was measured in a conduction-cooled setup. A model describing the coils, based on tape data, was created and revealed that the measurements were in excellent agreement with the predictions. Additional experiments were performed to study the quench and thermal runaway behaviour of the HTS coils, determining whether such coils can be protected against fault scenarios, using realistic quench-detection levels and discharge extraction-rates. These experiments demonstrate that the coils are very robust and can be well protected against quenches and thermal-runaway events using common quench-protection measures with realistic parameters.
- Open Access
- 1 March 2020
- Published by Elsevier in Cryogenics
- Vol. 106, 103026
Heat-triggered two-phase flow maldistribution in a micromachined cryogenic cooler
- 1 March 2020
- Published by Elsevier in Cryogenics
- Vol. 106, 103026
Open AccessHeat-triggered two-phase flow maldistribution in a micromachined cryogenic cooler
- Open Access
- 17 July 2015
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 33 (6) , 061601
Long-life micro vacuum chamber for a micromachined cryogenic cooler
Micromachined cryogenic coolers can be used for cooling small electronic devices to improve their performance. However, for reaching cryogenic temperatures, they require a very good thermal insulation from the warm environment. This is established by a vacuum space that for adequate insulation has to be maintained at a pressure of 0.01 Pa or lower. In this paper, the challenge of maintaining a vacuum chamber with a volume of 3.6 × 10−5 m3 and an inner wall area of 8.1 × 10−3 m2 at a pressure no higher than 0.01 Pa for five years is theoretically analyzed. The possible sources of gas, the mechanisms by which these gases enter the vacuum space and their effects on the pressure in the vacuum chamber are discussed. In a long-duration experiment with four stainless steel chambers of the above dimensions and equipped with a chemical getter, the vacuum pressures were monitored for a period of two years. In that period, the measured pressure increase stayed within 0.01 Pa. This study can be used to guide the design of long-lifetime micro vacuum chambers that operate without continuous mechanical pumping.
- 17 July 2015
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 33 (6) , 061601
Open AccessLong-life micro vacuum chamber for a micromachined cryogenic cooler
Micromachined cryogenic coolers can be used for cooling small electronic devices to improve their performance. However, for reaching cryogenic temperatures, they require a very good thermal insulation from the warm environment. This is established by a vacuum space that for adequate insulation has to be maintained at a pressure of 0.01 Pa or lower. In this paper, the challenge of maintaining a vacuum chamber with a volume of 3.6 × 10−5 m3 and an inner wall area of 8.1 × 10−3 m2 at a pressure no higher than 0.01 Pa for five years is theoretically analyzed. The possible sources of gas, the mechanisms by which these gases enter the vacuum space and their effects on the pressure in the vacuum chamber are discussed. In a long-duration experiment with four stainless steel chambers of the above dimensions and equipped with a chemical getter, the vacuum pressures were monitored for a period of two years. In that period, the measured pressure increase stayed within 0.01 Pa. This study can be used to guide the design of long-lifetime micro vacuum chambers that operate without continuous mechanical pumping.