VTVicente Garcia Tavora

Vicente Garcia Tavora

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vicente Garcia Tavora has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microdosimetry Maps in Continuous and Pulsed Alpha Beams

    by Yuwei Zhu, Carla Riera-Llobet, Celeste Fleta, María Manna, Amélia Maia Leite, Gastón García López, Vicente García Távora, Diana Bachiller-Perea, Quentin Mouchard, Consuelo Guardiola

    The experimental assessment of the linear energy transfer (LET) at micrometric scale with high resolution is mandatory to achieve biologically optimized treatment plans in hadron therapy. Therefore, it is crucial to create active radiation sensors able to quantify microdosimetry distributions in three-dimensions under clinical conditions. We have quantified the first microdosimetry 2D-maps delivered by alpha beams with the highest resolution so far (400 μm × 600 μm) using a customized sensor. It consists of 3 multi-arrays of 50 3 × 3 microdetectors with a pitch of 200 μm that cover a total radiation sensitive area of 9 cm × 0.4 mm. The microdetectors are based on a novel 3D-cylindrical silicon architecture with 25-μm diameter and 20-μm thickness. The back-side of these sensors is etched to avoid back-scattering contributions in heavy ion fields. This system was calibrated with alpha beams from 5.75 to 20 MeV in the Accelerateur Lineaire et Tandem a Orsay (ALTO), France, and irradiated with pulsed beams (from 1.4 μs to 3.3 μs pulse widths) of 7.5 MeV alphas in the Centro de Micro-Analisis de Materiales (CMAM), Spain. We worked with clinical equivalent fluence rates in both continuous irradiation mode (~ 10 cm-2s-1) and in pulsed regimes with higher fluence rates up to ~ 1010 cm-2-s-1. Measurements of pulse height spectra were collected with the sensor in both modes. The experimental results were crosschecked with Monte Carlo simulations using the GATE code. The simulated spectral shapes and peak positions showed good agreement with the experimental data, with relative differences of less than 3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes.

  • Ultra-low fluence irradiation with energetic heavy ion pulsed beam using a modified electrostatic raster scanner

    by Joseph T Graham, José Olivares, Vicente Garcia Tavora, Esther Enríquez Pérez, Santanu Kumar Padhi, Miguel Crespillo, Gastón García López

    A method for performing low fluence pulsed irradiations with energetic heavy ions is presented. A raster scanner, placed upstream from a sample target chamber, is externally driven by a voltage pulse generated by a function generator. The configuration is similar to an electrostatic chopper, where a voltage difference across the scanner’s electrodes sweeps the beam across the sample, placed slightly off center from the beam axis, resulting in a short irradiation pulse on the sample and a low particle fluence. Such a system was developed at the Centre for Micro Analysis of Materials (CMAM) facility and characterized using 9 MeV F and 18 MeV Cl ions. The system can generate pulses of a few microseconds duration, depending on ion energy and charge state. A diagnostic method for measuring the fluence on the samples by counting etched ion tracks is described. A fluence on the order of 106 cm−2 was obtained by this method. This method could be adopted by other tandem ion accelerator facilities through simple and inexpensive modifications of existing beam handling instruments.

  • Open Access

    Iodine-substituted hydroxyapatite nanoparticles and activation of derived ceramics for range verification in proton therapy

    by R. Magro Hernández, A. Muñoz-Noval, J. A. Briz, J. R. Murias, A. Espinosa-Rodríguez, L. M. Fraile, F. Agulló-Rueda, M. D. Ynsa, C. Tavares de Sousa, B. Cortés-Llanos, et al.

    Iodine-substituted hydroxyapatite nanomaterials were synthesised via hydrothermal process to use iodine (127I) as a proton radiation reporter with a view in hard tissue phantoms for proton therapy.


  • Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators

    by J. A. Briz, A. N. Nerio, C. Ballesteros, M. J. G. Borge, P. Martinez, A. Perea, V. G. Tavora, O. Tengblad, M. Ciemala, A. Maj, et al.

    Proton therapy is a cancer treatment technique currently in growth since it offers advantages with respect to conventional X-ray and $\gamma $ -ray radiotherapy. In particular, better control of the dose deposition allowing to reach higher conformity in the treatments causing less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton computed tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Our prototype is formed by double-sided silicon strip detectors and scintillators of LaBr 3 (Ce) with high energy resolution and fast response. Here, the results obtained from an experiment performed using a 100-MeV proton beam are presented. Proton radiographs of polymethyl methacrylate (PMMA) samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution, and sensitivity to different materials. Structures of up to 2 mm are well resolved and the sensitivity of the system was enough to distinguish the thicknesses of 10 mm of aluminum or PMMA. The spatial resolution of the images was 0.3 line pairs per mm (MTF-10%). This constitutes the first step to validate the device as a proton radiography scanner.