Gaston Garcia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gaston Garcia has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
J. Olivares
Centro de Microanálisis de Materiales (CMAM), Universidad Autónoma de Madrid (UAM), Madrid, Spain
3 shared publications- Vicente Garcia Tavora
Universidad Autónoma de Madrid (UAM)
3 shared publications - Arturo Galindo
Instituto de Ciencia de Materiales de Madrid, Consejo Superior de Investigaciones Científicas (CSIC)
2 shared publications - Belén Cortés-Llanos
Centro de Microanálisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Campus de Cantoblanco, Madrid, 28049, Spain
2 shared publications - Carmen Morant
Autonomous University of Madrid, Spain
2 shared publications - Celia Polop
Departamento de Física de la Materia Condensada Universidad Autónoma de Madrid Madrid Spain
2 shared publications
Latest Publications
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 799-814
Microdosimetry Maps in Continuous and Pulsed Alpha Beams
The experimental assessment of the linear energy transfer (LET) at micrometric scale with high resolution is mandatory to achieve biologically optimized treatment plans in hadron therapy. Therefore, it is crucial to create active radiation sensors able to quantify microdosimetry distributions in three-dimensions under clinical conditions. We have quantified the first microdosimetry 2D-maps delivered by alpha beams with the highest resolution so far (400 μm × 600 μm) using a customized sensor. It consists of 3 multi-arrays of 50 3 × 3 microdetectors with a pitch of 200 μm that cover a total radiation sensitive area of 9 cm × 0.4 mm. The microdetectors are based on a novel 3D-cylindrical silicon architecture with 25-μm diameter and 20-μm thickness. The back-side of these sensors is etched to avoid back-scattering contributions in heavy ion fields. This system was calibrated with alpha beams from 5.75 to 20 MeV in the Accelerateur Lineaire et Tandem a Orsay (ALTO), France, and irradiated with pulsed beams (from 1.4 μs to 3.3 μs pulse widths) of 7.5 MeV alphas in the Centro de Micro-Analisis de Materiales (CMAM), Spain. We worked with clinical equivalent fluence rates in both continuous irradiation mode (~ 10 cm-2s-1) and in pulsed regimes with higher fluence rates up to ~ 1010 cm-2-s-1. Measurements of pulse height spectra were collected with the sensor in both modes. The experimental results were crosschecked with Monte Carlo simulations using the GATE code. The simulated spectral shapes and peak positions showed good agreement with the experimental data, with relative differences of less than 3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 799-814
Microdosimetry Maps in Continuous and Pulsed Alpha Beams
The experimental assessment of the linear energy transfer (LET) at micrometric scale with high resolution is mandatory to achieve biologically optimized treatment plans in hadron therapy. Therefore, it is crucial to create active radiation sensors able to quantify microdosimetry distributions in three-dimensions under clinical conditions. We have quantified the first microdosimetry 2D-maps delivered by alpha beams with the highest resolution so far (400 μm × 600 μm) using a customized sensor. It consists of 3 multi-arrays of 50 3 × 3 microdetectors with a pitch of 200 μm that cover a total radiation sensitive area of 9 cm × 0.4 mm. The microdetectors are based on a novel 3D-cylindrical silicon architecture with 25-μm diameter and 20-μm thickness. The back-side of these sensors is etched to avoid back-scattering contributions in heavy ion fields. This system was calibrated with alpha beams from 5.75 to 20 MeV in the Accelerateur Lineaire et Tandem a Orsay (ALTO), France, and irradiated with pulsed beams (from 1.4 μs to 3.3 μs pulse widths) of 7.5 MeV alphas in the Centro de Micro-Analisis de Materiales (CMAM), Spain. We worked with clinical equivalent fluence rates in both continuous irradiation mode (~ 10 cm-2s-1) and in pulsed regimes with higher fluence rates up to ~ 1010 cm-2-s-1. Measurements of pulse height spectra were collected with the sensor in both modes. The experimental results were crosschecked with Monte Carlo simulations using the GATE code. The simulated spectral shapes and peak positions showed good agreement with the experimental data, with relative differences of less than 3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes.
- Open Access
- 18 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8)
Development and characterisation of a radiobiology proton beamline using radiochromic film dosimetry
Objective: To develop and optimise a dedicated low-energy proton beamline at the Centre for Micro-Analysis of Materials (CMAM, Madrid, Spain) for radiobiological applications. Approach: An automated irradiation system was implemented, integrating Gafchromic EBT3 radiochromic film (RCF) dosimetry corrected for linear energy transfer (LET) dependent quenching and post-irradiation darkening. Dosimetric calibration was performed using multichannel analysis, and beam performance was systematically evaluated as a function of distance, raster scanning area, beam intensity and reproducibility. Main results: Optimal operating conditions were identified at moderate beam currents (≤ 1 nA) and scanning areas of 40 × 40 to 50 × 50 mm2, yielding homogeneous dose distributions with reproducibility better than 8%. The dosimetric protocol demonstrated linearity across clinically relevant dose ranges and allowed a reliable correlation between irradiation parameters and absorbed dose. Proof-of-concept experiments on U-87MG glioblastoma cells confirmed the system’s ability to deliver controlled and biologically effective proton exposures, as demonstrated by clonogenic survival assays. Significance: These results establish the CMAM beamline as a robust and versatile platform for preclinical proton radiobiology, providing accurate dosimetric control and supporting investigations of relative biological efficacy (RBE). The system facilitates translational advances in proton radiobiology, bridging physical and biological studies in low-energy proton irradiation.
- 18 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8)
Open AccessDevelopment and characterisation of a radiobiology proton beamline using radiochromic film dosimetry
Objective: To develop and optimise a dedicated low-energy proton beamline at the Centre for Micro-Analysis of Materials (CMAM, Madrid, Spain) for radiobiological applications. Approach: An automated irradiation system was implemented, integrating Gafchromic EBT3 radiochromic film (RCF) dosimetry corrected for linear energy transfer (LET) dependent quenching and post-irradiation darkening. Dosimetric calibration was performed using multichannel analysis, and beam performance was systematically evaluated as a function of distance, raster scanning area, beam intensity and reproducibility. Main results: Optimal operating conditions were identified at moderate beam currents (≤ 1 nA) and scanning areas of 40 × 40 to 50 × 50 mm2, yielding homogeneous dose distributions with reproducibility better than 8%. The dosimetric protocol demonstrated linearity across clinically relevant dose ranges and allowed a reliable correlation between irradiation parameters and absorbed dose. Proof-of-concept experiments on U-87MG glioblastoma cells confirmed the system’s ability to deliver controlled and biologically effective proton exposures, as demonstrated by clonogenic survival assays. Significance: These results establish the CMAM beamline as a robust and versatile platform for preclinical proton radiobiology, providing accurate dosimetric control and supporting investigations of relative biological efficacy (RBE). The system facilitates translational advances in proton radiobiology, bridging physical and biological studies in low-energy proton irradiation.
- Open Access
- 29 December 2025
- Published by Wiley in Battery Energy
- Vol. 5 (1)
Lithiation Analysis of Metal Components for Li‐Ion Battery Using Ion Beams
Metal components are extensively used as current collectors, anodes, and interlayers in lithium‐ion batteries. Integrating these functions into one component enhances the cell's energy density and simplifies its design. However, this multifunctional component must meet stringent requirements, including high and reversible Li storage capacity, rapid lithiation/delithiation kinetics, mechanical stability, and safety. Six single‐atom metals (Mg, Zn, Al, Ag, Sn, and Cu) are screened for lithiation behavior through their interaction with ion beams in electrochemically tested samples subjected to both weak and strong lithiation regimes. These different lithiation regimes allowed us to differentiate between the thermodynamics and kinetic aspects of the lithiation process. Three types of ions are used to determine Li depth profile: H + for nuclear reaction analysis (NRA), He + for Rutherford backscattering (RBS), and Ga + for focused ion beam milling. The study reveals three lithiation behaviors: (i) Zn, Al, Sn form pure alloys with Li; (ii) Mg, Ag create intercalation solid solutions; (iii) Cu acts as a lithiation barrier. NRA and RBS offer direct and quantitative data, providing a more comprehensive understanding of the lithiation process in LIB components. These findings fit well with our ab initio simulation results, establishing a direct correlation between electrochemical features and fundamental thermodynamic parameters.
- 29 December 2025
- Published by Wiley in Battery Energy
- Vol. 5 (1)
Open AccessLithiation Analysis of Metal Components for Li‐Ion Battery Using Ion Beams
Metal components are extensively used as current collectors, anodes, and interlayers in lithium‐ion batteries. Integrating these functions into one component enhances the cell's energy density and simplifies its design. However, this multifunctional component must meet stringent requirements, including high and reversible Li storage capacity, rapid lithiation/delithiation kinetics, mechanical stability, and safety. Six single‐atom metals (Mg, Zn, Al, Ag, Sn, and Cu) are screened for lithiation behavior through their interaction with ion beams in electrochemically tested samples subjected to both weak and strong lithiation regimes. These different lithiation regimes allowed us to differentiate between the thermodynamics and kinetic aspects of the lithiation process. Three types of ions are used to determine Li depth profile: H + for nuclear reaction analysis (NRA), He + for Rutherford backscattering (RBS), and Ga + for focused ion beam milling. The study reveals three lithiation behaviors: (i) Zn, Al, Sn form pure alloys with Li; (ii) Mg, Ag create intercalation solid solutions; (iii) Cu acts as a lithiation barrier. NRA and RBS offer direct and quantitative data, providing a more comprehensive understanding of the lithiation process in LIB components. These findings fit well with our ab initio simulation results, establishing a direct correlation between electrochemical features and fundamental thermodynamic parameters.
- Open Access
- 21 August 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 44
Simultaneous characterization of O, C, 6Li, and medium-weight impurities concentration in PbLi by ion beam analysis
- 21 August 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 44
Open AccessSimultaneous characterization of O, C, 6Li, and medium-weight impurities concentration in PbLi by ion beam analysis
- Open Access
- 30 July 2025
- Published by Wiley in Batteries & Supercaps
- Vol. 8 (12)
Charge Compensation Mechanisms in Ni‐Rich NMC Cathodes
Understanding charge compensation mechanisms in nickel‐rich lithium nickel–manganese–cobalt alloy oxide (NMC) cathodes is crucial for optimizing their electrochemical performance. This study employs complementary spectroscopic techniques with varying probing depths, including X‐ray absorption near‐edge structure spectroscopy, hard X‐ray photoemission spectroscopy, X‐ray photoelectron spectroscopy, and ion beam analysis, to investigate the correlation between transition metal oxidation states and Li depth profile in NMC811. This approach reveals different charge compensation mechanisms depending on the local Li content, which exhibits near‐surface gradients. The results show that Ni oxidation is the main charge compensation mechanism for moderate delithiations at a Li stoichiometry x > 0.35. When the Li content drops below the threshold x = 0.3, which occurs near the surface for high state of charge (SOC), compensation by Ni/Li mixing prevails. Meanwhile, the Li‐depleted surface (with x ≪ 0.3) shows evidence of transformation into electrochemically inactive Li‐free cubic phases. The voltage window used to cycle the NMC811 prevents the bulk Li content from falling below x = 0.35, so the different charge compensation mechanisms coexist for high SOCs, allowing to compare between their kinetics. This study contributes to a comprehensive understanding of the electrochemical behavior of nickel‐rich NMCs, aiding the development of high‐energy Li‐ion batteries with improved stability.
- 30 July 2025
- Published by Wiley in Batteries & Supercaps
- Vol. 8 (12)
Open AccessCharge Compensation Mechanisms in Ni‐Rich NMC Cathodes
Understanding charge compensation mechanisms in nickel‐rich lithium nickel–manganese–cobalt alloy oxide (NMC) cathodes is crucial for optimizing their electrochemical performance. This study employs complementary spectroscopic techniques with varying probing depths, including X‐ray absorption near‐edge structure spectroscopy, hard X‐ray photoemission spectroscopy, X‐ray photoelectron spectroscopy, and ion beam analysis, to investigate the correlation between transition metal oxidation states and Li depth profile in NMC811. This approach reveals different charge compensation mechanisms depending on the local Li content, which exhibits near‐surface gradients. The results show that Ni oxidation is the main charge compensation mechanism for moderate delithiations at a Li stoichiometry x > 0.35. When the Li content drops below the threshold x = 0.3, which occurs near the surface for high state of charge (SOC), compensation by Ni/Li mixing prevails. Meanwhile, the Li‐depleted surface (with x ≪ 0.3) shows evidence of transformation into electrochemically inactive Li‐free cubic phases. The voltage window used to cycle the NMC811 prevents the bulk Li content from falling below x = 0.35, so the different charge compensation mechanisms coexist for high SOCs, allowing to compare between their kinetics. This study contributes to a comprehensive understanding of the electrochemical behavior of nickel‐rich NMCs, aiding the development of high‐energy Li‐ion batteries with improved stability.
- Open Access
- 17 March 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (11)
Quest for amorphous superconductors of Bi–Sb alloys by irradiation with swift heavy ions
Crystalline Bi100−xSbx alloys are known as the first discovered topological insulators, as well as for their promising thermoelectric properties, while their amorphous counterparts exhibit superconductivity (Tc > 6 K). However, their strong tendency to crystallize has hindered both the study and practical applications of amorphous Bi and Bi–Sb alloys. To explore the possibility of obtaining amorphous superconducting phases and enhancing thermoelectric properties, we investigated ion-beam irradiation as a method to induce amorphization in Bi100−xSbx alloys. We report irradiation experiments on pure Bi and Bi100−xSbx using bismuth and iodine ions (tens of MeV), generating an estimated vacancy damage of 40%–80%. Structural characterization and electrical resistivity measurements (2–300 K) revealed that, while amorphization and superconductivity were not achieved, melt-spun samples exhibited an order of magnitude higher conductivity than thermally evaporated ones. Moreover, ion-induced disorder further improved electrical conductivity, particularly in Bi90Sb10, highlighting its potential for thermoelectric applications.
- 17 March 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (11)
Open AccessQuest for amorphous superconductors of Bi–Sb alloys by irradiation with swift heavy ions
Crystalline Bi100−xSbx alloys are known as the first discovered topological insulators, as well as for their promising thermoelectric properties, while their amorphous counterparts exhibit superconductivity (Tc > 6 K). However, their strong tendency to crystallize has hindered both the study and practical applications of amorphous Bi and Bi–Sb alloys. To explore the possibility of obtaining amorphous superconducting phases and enhancing thermoelectric properties, we investigated ion-beam irradiation as a method to induce amorphization in Bi100−xSbx alloys. We report irradiation experiments on pure Bi and Bi100−xSbx using bismuth and iodine ions (tens of MeV), generating an estimated vacancy damage of 40%–80%. Structural characterization and electrical resistivity measurements (2–300 K) revealed that, while amorphization and superconductivity were not achieved, melt-spun samples exhibited an order of magnitude higher conductivity than thermally evaporated ones. Moreover, ion-induced disorder further improved electrical conductivity, particularly in Bi90Sb10, highlighting its potential for thermoelectric applications.
- 27 February 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (3) , 035031
Ultra-low fluence irradiation with energetic heavy ion pulsed beam using a modified electrostatic raster scanner
A method for performing low fluence pulsed irradiations with energetic heavy ions is presented. A raster scanner, placed upstream from a sample target chamber, is externally driven by a voltage pulse generated by a function generator. The configuration is similar to an electrostatic chopper, where a voltage difference across the scanner’s electrodes sweeps the beam across the sample, placed slightly off center from the beam axis, resulting in a short irradiation pulse on the sample and a low particle fluence. Such a system was developed at the Centre for Micro Analysis of Materials (CMAM) facility and characterized using 9 MeV F and 18 MeV Cl ions. The system can generate pulses of a few microseconds duration, depending on ion energy and charge state. A diagnostic method for measuring the fluence on the samples by counting etched ion tracks is described. A fluence on the order of 106 cm−2 was obtained by this method. This method could be adopted by other tandem ion accelerator facilities through simple and inexpensive modifications of existing beam handling instruments.
- 27 February 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (3) , 035031
Ultra-low fluence irradiation with energetic heavy ion pulsed beam using a modified electrostatic raster scanner
A method for performing low fluence pulsed irradiations with energetic heavy ions is presented. A raster scanner, placed upstream from a sample target chamber, is externally driven by a voltage pulse generated by a function generator. The configuration is similar to an electrostatic chopper, where a voltage difference across the scanner’s electrodes sweeps the beam across the sample, placed slightly off center from the beam axis, resulting in a short irradiation pulse on the sample and a low particle fluence. Such a system was developed at the Centre for Micro Analysis of Materials (CMAM) facility and characterized using 9 MeV F and 18 MeV Cl ions. The system can generate pulses of a few microseconds duration, depending on ion energy and charge state. A diagnostic method for measuring the fluence on the samples by counting etched ion tracks is described. A fluence on the order of 106 cm−2 was obtained by this method. This method could be adopted by other tandem ion accelerator facilities through simple and inexpensive modifications of existing beam handling instruments.
- Open Access
- 15 October 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 12 (46) , 12030-12037
Iodine-substituted hydroxyapatite nanoparticles and activation of derived ceramics for range verification in proton therapy
Iodine-substituted hydroxyapatite nanomaterials were synthesised via hydrothermal process to use iodine (127I) as a proton radiation reporter with a view in hard tissue phantoms for proton therapy.
- 15 October 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 12 (46) , 12030-12037
Open AccessIodine-substituted hydroxyapatite nanoparticles and activation of derived ceramics for range verification in proton therapy
Iodine-substituted hydroxyapatite nanomaterials were synthesised via hydrothermal process to use iodine (127I) as a proton radiation reporter with a view in hard tissue phantoms for proton therapy.
- Open Access
- 4 November 2023
- Published by Elsevier in Acta Materialia
- Vol. 263
Unveiling the radiation-induced defect production and damage evolution in tungsten using multi-energy Rutherford backscattering spectroscopy in channeling configuration
- 4 November 2023
- Published by Elsevier in Acta Materialia
- Vol. 263
Open AccessUnveiling the radiation-induced defect production and damage evolution in tungsten using multi-energy Rutherford backscattering spectroscopy in channeling configuration
- Open Access
- 23 August 2023
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 586
Characterization of the lithium concentration and distribution as a function of depth for alumina coatings after exposure to PbLi
- 23 August 2023
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 586
Open AccessCharacterization of the lithium concentration and distribution as a function of depth for alumina coatings after exposure to PbLi