Evgeny Osetrov
Evgeny Osetrov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alexey Loskutov
Department of Electric Power Engineering, Power Supply and Power Electronics, Nizhny Novgorod State Technical University n.a. R.E. Alekseev, 603155 Nizhny Novgorod, Russia
3 shared publications - Andrey Kurkin
Department of Applied Mathematics, Nizhny Novgorod State Technical University n.a. R.E. Alekseev, Nizhny Novgorod 603155, Russia
3 shared publications - Aleksandr Voropay
Technocomplekt LLC, 141981 Dubna, Russia
2 shared publications - Grigoriy Tsepilov
Technocomplekt LLC, 141981 Dubna, Russia
2 shared publications - Ilia Rashitov
Technocomplekt LLC, 141981 Dubna, Russia
2 shared publications - Ivan A. Lipuzhin
Alekseev Nizhny Novgorod State Technical University, Nizhny Novgorod, Russia
2 shared publications
Latest Publications
- Open Access
Study of 10 kW Vanadium Flow Battery Discharge Characteristics at Different Load Powers
Vanadium redox flow batteries are promising energy storage devices and are already ahead of lead–acid batteries in terms of installed capacity in energy systems due to their long service life and possibility of recycling. One of the crucial tasks today is the development of models for assessing battery performance and its residual resource based on the battery’s present state. A promising method for estimating battery capacity is based on analyzing present voltage and current values under various load conditions. This paper analyzes the discharge characteristics of a 10 kW all-vanadium redox flow battery at fixed load powers from 6 to 12 kW. A linear dependence of operating voltage and initial discharge voltage on load power is established. It is also determined that the slope of the discharge curve linear section does not increase linearly in absolute value, and the Box–Lucas model can be used to describe it. Models for predicting current VRFB capacity based on different curve fitting functions are proposed. These models can be used to roughly estimate battery capacity at different load powers.
Open AccessStudy of 10 kW Vanadium Flow Battery Discharge Characteristics at Different Load Powers
Vanadium redox flow batteries are promising energy storage devices and are already ahead of lead–acid batteries in terms of installed capacity in energy systems due to their long service life and possibility of recycling. One of the crucial tasks today is the development of models for assessing battery performance and its residual resource based on the battery’s present state. A promising method for estimating battery capacity is based on analyzing present voltage and current values under various load conditions. This paper analyzes the discharge characteristics of a 10 kW all-vanadium redox flow battery at fixed load powers from 6 to 12 kW. A linear dependence of operating voltage and initial discharge voltage on load power is established. It is also determined that the slope of the discharge curve linear section does not increase linearly in absolute value, and the Box–Lucas model can be used to describe it. Models for predicting current VRFB capacity based on different curve fitting functions are proposed. These models can be used to roughly estimate battery capacity at different load powers.
- Open Access
Vanadium Redox Flow Battery Stack Balancing to Increase Depth of Discharge Using Forced Flow Attenuation
Vanadium redox flow batteries are gaining great popularity in the world due to their long service life, simple (from a technological point of view) capacity increase and overload resistance, which hardly affects the service life. However, these batteries have technical problems, namely in balancing stacks with each other in terms of volumetric flow rate of electrolyte. Stack power depends on the speed of the electrolyte flow through the stack. Stacks are connected in parallel by electrolytes to increase battery power. If one of the stacks has a lower hydrodynamic resistance, the volume of electrolytes passing through it increases, which leads to a decrease in the efficiency of the remaining stacks in the system. This experimental study was conducted on a 10 kW uninterruptible power supply system based on two 5 kW stacks of all-vanadium redox flow batteries. It was demonstrated that forced flow attenuation in a circuit with low hydrodynamic resistance leads to an overall improvement in the system operation.
Open AccessVanadium Redox Flow Battery Stack Balancing to Increase Depth of Discharge Using Forced Flow Attenuation
Vanadium redox flow batteries are gaining great popularity in the world due to their long service life, simple (from a technological point of view) capacity increase and overload resistance, which hardly affects the service life. However, these batteries have technical problems, namely in balancing stacks with each other in terms of volumetric flow rate of electrolyte. Stack power depends on the speed of the electrolyte flow through the stack. Stacks are connected in parallel by electrolytes to increase battery power. If one of the stacks has a lower hydrodynamic resistance, the volume of electrolytes passing through it increases, which leads to a decrease in the efficiency of the remaining stacks in the system. This experimental study was conducted on a 10 kW uninterruptible power supply system based on two 5 kW stacks of all-vanadium redox flow batteries. It was demonstrated that forced flow attenuation in a circuit with low hydrodynamic resistance leads to an overall improvement in the system operation.
- Open Access
Source for Autonomous Power Supply System Based on Flow Battery
The article deals with the urgent task of creating a technological and production basis for the development and serial production of energy storage systems with flow batteries and uninterruptible power systems based on them. Flow batteries are a highly efficient solution for long-term energy storage in critical and alternative energy facilities. The main advantage of the flow batteries is the ability to create a system with the required power and capacity without redundant parameters due to the fact that the characteristics of the system are regulated by independent blocks, as in a fuel cell. Among flow batteries, vanadium redox flow batteries (VRFB) are of particular interest, as they have a long service life. The main elements of a flow battery are the stack, which determines the power of the battery and its efficiency, and the electrolyte, which determines the energy capacity of the battery and its service life. A stand for testing the operating modes of the flow battery stack has been developed. A 5 kW flow battery operating on an electrolyte with the addition of hydrochloric acid, which is a stabilizer in new generation electrolytes, has been tested.
Open AccessSource for Autonomous Power Supply System Based on Flow Battery
The article deals with the urgent task of creating a technological and production basis for the development and serial production of energy storage systems with flow batteries and uninterruptible power systems based on them. Flow batteries are a highly efficient solution for long-term energy storage in critical and alternative energy facilities. The main advantage of the flow batteries is the ability to create a system with the required power and capacity without redundant parameters due to the fact that the characteristics of the system are regulated by independent blocks, as in a fuel cell. Among flow batteries, vanadium redox flow batteries (VRFB) are of particular interest, as they have a long service life. The main elements of a flow battery are the stack, which determines the power of the battery and its efficiency, and the electrolyte, which determines the energy capacity of the battery and its service life. A stand for testing the operating modes of the flow battery stack has been developed. A 5 kW flow battery operating on an electrolyte with the addition of hydrochloric acid, which is a stabilizer in new generation electrolytes, has been tested.