Haluk Baris Kara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Haluk Baris Kara has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
A. Nilgun Ozturk
Selcuk University
2 shared publicationsFiliz Aykent
Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, TURKIYE
2 shared publicationsOzlem Koc
Selcuk University
2 shared publicationsBora Ozturk
Selcuk University
1 shared publicationBurcu Yilmaz
Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Istanbul Medipol University, Istanbul, Turkey
1 shared publication- Erhan Dilber
Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Alanya 07490, Türkiye
1 shared publication
Latest Publications
- 21 July 2016
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 28 (6) , 405-411
Efficacy of Diode Laser and Gluma on Post‐Preparation Sensitivity: A Randomized Split‐Mouth Clinical Study
Objective: This study aimed to compare the efficacy of a 940‐nm diode laser and Gluma desensitizer on post‐preparation sensitivity of prepared teeth.Materials and Methods: Twenty patients with 76 teeth participated in the study. For each patient, prepared molar or premolar in one quadrant were individually irradiated by laser. In the symmetrical quadrant, Gluma was applied onto the prepared teeth. No treatment was performed in the control group. Temporary crowns were placed after preparation. Pain response to tactile stimulus was assessed at one day, one week, and two weeks using visual analog scale (VAS). Intergroup comparisons were made with Kruskal Wallis test (p < 0.05).Results: Mean VAS scores of the control group were statistically higher than laser and Gluma groups (p < 0.017). The difference between VAS scores of the laser and Gluma groups was statistically insignificant (p > 0.05).Conclusions: A significant reduction in level of sensitivity after both treatments was observed. The reduction of sensitivity with Gluma was not significantly superior to laser. No significant additional reduction occurred in level of sensitivity from the first day to the second week after both treatments.Clinical Significance: The application of Gluma or a 940‐nm diode laser may be considered as effective in reducing sensitivity after tooth preparation without superiority of either method. (J Esthet Restor Dent 28:405–411, 2016)
- 21 July 2016
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 28 (6) , 405-411
Efficacy of Diode Laser and Gluma on Post‐Preparation Sensitivity: A Randomized Split‐Mouth Clinical Study
Objective: This study aimed to compare the efficacy of a 940‐nm diode laser and Gluma desensitizer on post‐preparation sensitivity of prepared teeth.Materials and Methods: Twenty patients with 76 teeth participated in the study. For each patient, prepared molar or premolar in one quadrant were individually irradiated by laser. In the symmetrical quadrant, Gluma was applied onto the prepared teeth. No treatment was performed in the control group. Temporary crowns were placed after preparation. Pain response to tactile stimulus was assessed at one day, one week, and two weeks using visual analog scale (VAS). Intergroup comparisons were made with Kruskal Wallis test (p < 0.05).Results: Mean VAS scores of the control group were statistically higher than laser and Gluma groups (p < 0.017). The difference between VAS scores of the laser and Gluma groups was statistically insignificant (p > 0.05).Conclusions: A significant reduction in level of sensitivity after both treatments was observed. The reduction of sensitivity with Gluma was not significantly superior to laser. No significant additional reduction occurred in level of sensitivity from the first day to the second week after both treatments.Clinical Significance: The application of Gluma or a 940‐nm diode laser may be considered as effective in reducing sensitivity after tooth preparation without superiority of either method. (J Esthet Restor Dent 28:405–411, 2016)
- Open Access
- 1 January 2012
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 06 (01) , 101-104
Single tooth replacement using a ceramic resin bonded fixed partial denture: A case report
This article describes the use of an all ceramic resin-bonded fixed partial denture as a conservative solution for the replacement of an incisor. It is a minimally invasive technique that does not discolor the abutment teeth. (Eur J Dent 2012;6:101-104)
- 1 January 2012
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 06 (01) , 101-104
Open AccessSingle tooth replacement using a ceramic resin bonded fixed partial denture: A case report
This article describes the use of an all ceramic resin-bonded fixed partial denture as a conservative solution for the replacement of an incisor. It is a minimally invasive technique that does not discolor the abutment teeth. (Eur J Dent 2012;6:101-104)
- 26 November 2010
- Published by Springer Nature in Lasers in Medical Science
- Vol. 27 (2) , 267-272
Effect of different surface treatments on roughness of IPS Empress 2 ceramic
The aim of this study was to evaluate the influence of different surface treatments (air abrasion, acid etching, laser irradiation) on the surface roughness of a lithium-disilicate-based core ceramic. A total of 40 discs of lithium disilicate-based core ceramic (IPS Empress 2; Ivoclar Vivadent, Schaan, Liechtenstein) were prepared (10 mm in diameter and 1 mm in thickness) according to the manufacturer’s instructions. Specimens were divided into four groups (n = 10), and the following treatments were applied: air abrasion with alumina particles (50 μm), acid etching with 5% hydrofluoric acid, Nd:YAG laser irradiation (1 mm distance, 100 mJ, 20 Hz, 2 W) and Er:YAG laser irradiation (1 mm distance, 500 mJ, 20 Hz, 10 W). Following determination of surface roughness (Ra) by profilometry, specimens were examined with atomic force microscopy. The data were analysed by one-way analysis of variance (ANOVA) and Tukey HSD test (α = 0.05). One-way ANOVA indicated that surface roughness following air abrasion was significantly different from the surface roughness following laser irradiation and acid etching (P < 0.001). The Tukey HSD test indicated that the air abrasion group had a significantly higher mean value of roughness (P < 0.05) than the other groups. No significant difference was found between the acid etching and laser irradiation (both Er:YAG and Nd:YAG) groups (P > 0.05). Air abrasion increased surface roughness of lithium disilicate-based core ceramic surfaces more effectively than acid-etching and laser irradiation.
- 26 November 2010
- Published by Springer Nature in Lasers in Medical Science
- Vol. 27 (2) , 267-272
Effect of different surface treatments on roughness of IPS Empress 2 ceramic
The aim of this study was to evaluate the influence of different surface treatments (air abrasion, acid etching, laser irradiation) on the surface roughness of a lithium-disilicate-based core ceramic. A total of 40 discs of lithium disilicate-based core ceramic (IPS Empress 2; Ivoclar Vivadent, Schaan, Liechtenstein) were prepared (10 mm in diameter and 1 mm in thickness) according to the manufacturer’s instructions. Specimens were divided into four groups (n = 10), and the following treatments were applied: air abrasion with alumina particles (50 μm), acid etching with 5% hydrofluoric acid, Nd:YAG laser irradiation (1 mm distance, 100 mJ, 20 Hz, 2 W) and Er:YAG laser irradiation (1 mm distance, 500 mJ, 20 Hz, 10 W). Following determination of surface roughness (Ra) by profilometry, specimens were examined with atomic force microscopy. The data were analysed by one-way analysis of variance (ANOVA) and Tukey HSD test (α = 0.05). One-way ANOVA indicated that surface roughness following air abrasion was significantly different from the surface roughness following laser irradiation and acid etching (P < 0.001). The Tukey HSD test indicated that the air abrasion group had a significantly higher mean value of roughness (P < 0.05) than the other groups. No significant difference was found between the acid etching and laser irradiation (both Er:YAG and Nd:YAG) groups (P > 0.05). Air abrasion increased surface roughness of lithium disilicate-based core ceramic surfaces more effectively than acid-etching and laser irradiation.
- 29 June 2010
- Published by Springer Nature in Lasers in Medical Science
- Vol. 26 (5) , 599-604
The effect of different surface treatments on roughnessand bond strength in low fusing ceramics
The aim of this study was to evaluate the influence of different surface treatments (air abrasion, acid etching, and laser irradiation) on the surface roughness and bond strength of a low fusing ceramic. Thirty-six discs of low fusing ceramic (Finesse, Ceramco) were prepared (10 mm in diameter and 2 mm in thickness) according to the manufacturer’s instructions. Specimens were divided into three groups (n = 12), and the following treatments were performed: Air abrasion with alumina particles (50 μm), acid etching with 5% HF and Nd:YAG laser irradiation (distance: 1 mm, 100 mJ, 20 Hz, 2 W, and 141.54 J/cm2). Following determination of surface roughness (Ra) by profilometry, specimens were examined with scanning electron microscopy (SEM). The luting cement (Clearfil Esthetic Cement) was bonded to the ceramic specimens using Teflon tubes. After 24 h of water storage, shear bond strength test was performed using a universal testing machine at a crosshead speed of 1 mm/min. The data were analyzed with two-way analysis of variance (ANOVA) and Tukey HSD tests (α = .05). Two-way ANOVA indicated that surface roughness was significantly affected by surface treatments (p < .001). Tukey honestly significant difference (HSD) indicated that the air abrasion group had a significantly higher mean value (p < .05) than the other groups. Shear bond strength was significantly affected by surface treatments (p < .001). Tukey HSD indicated that the air abrasion group had a significantly higher mean value (p < .05) than the other groups. No significant difference was found between the acid-etching and laser-irradiation groups (p > .05). The SEM image of the laser irradiation surface appeared to be relatively smooth as compared to the images of other the groups. Air abrasion of low-fusing porcelain surfaces was effective in improving the bond strength as compared to the acid-etching and laser-irradiation methods.
- 29 June 2010
- Published by Springer Nature in Lasers in Medical Science
- Vol. 26 (5) , 599-604
The effect of different surface treatments on roughnessand bond strength in low fusing ceramics
The aim of this study was to evaluate the influence of different surface treatments (air abrasion, acid etching, and laser irradiation) on the surface roughness and bond strength of a low fusing ceramic. Thirty-six discs of low fusing ceramic (Finesse, Ceramco) were prepared (10 mm in diameter and 2 mm in thickness) according to the manufacturer’s instructions. Specimens were divided into three groups (n = 12), and the following treatments were performed: Air abrasion with alumina particles (50 μm), acid etching with 5% HF and Nd:YAG laser irradiation (distance: 1 mm, 100 mJ, 20 Hz, 2 W, and 141.54 J/cm2). Following determination of surface roughness (Ra) by profilometry, specimens were examined with scanning electron microscopy (SEM). The luting cement (Clearfil Esthetic Cement) was bonded to the ceramic specimens using Teflon tubes. After 24 h of water storage, shear bond strength test was performed using a universal testing machine at a crosshead speed of 1 mm/min. The data were analyzed with two-way analysis of variance (ANOVA) and Tukey HSD tests (α = .05). Two-way ANOVA indicated that surface roughness was significantly affected by surface treatments (p < .001). Tukey honestly significant difference (HSD) indicated that the air abrasion group had a significantly higher mean value (p < .05) than the other groups. Shear bond strength was significantly affected by surface treatments (p < .001). Tukey HSD indicated that the air abrasion group had a significantly higher mean value (p < .05) than the other groups. No significant difference was found between the acid-etching and laser-irradiation groups (p > .05). The SEM image of the laser irradiation surface appeared to be relatively smooth as compared to the images of other the groups. Air abrasion of low-fusing porcelain surfaces was effective in improving the bond strength as compared to the acid-etching and laser-irradiation methods.