Silvio Leite DE Macedo Neto
Silvio Leite DE Macedo Neto has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Anderson Freitas
HOME, Brasília, Brazil
3 shared publications - Leonardo Rigobello Battaglion
Universidade de São Paulo, Brazil
2 shared publications - Bruno Do Nascimento Ohashi
Hospital Regional do Paranoa, Servico de Residencia Medica em Ortopedia e Traumatologia, Brazil
1 shared publication - Diogo Ranier DE Macedo Souto
Hospital Ortopédico e Medicina Especializada, Brazil
1 shared publication - Fabrício Reichert Barin
Research and Education Institute of the Orthopedics and Specialized Medicine Hospital (IPE-HOME), Brasília, Distrito Federal, Brazil
1 shared publication - Hebe Soledad Simões Gomes de Moura
Hospital Regional do Gama, Servico de Residencia Medica em Ortopedia e Traumatologia, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 34 (1)
BIOMECHANICAL EVALUATION OF FIXATION METHODS IN PATELLAR FRACTURES (AO 34-C3): AN IN VITRO ANALYSIS
Objective: To describe the biomechanical outcomes of five different fixation models, namely: tension band wiring (TB), anterior star-shaped locking plate (PS), lateral orthogonal locking plates (LP), and two additional models using BT and LP combined with a circumferential cerclage wire around the patella, referred to as BTO and PSO, respectively, in a comminuted patellar fracture (AO34C3). Methods: This study analyzed, using the finite element method (FEM), the following variables: total displacement, fragment displacement, maximum and minimum principal stresses, and total and localized von Mises stresses, under loading conditions of 1,500 N (R1) and 3,000 N (R2). Results: Results were presented as absolute values and percentiles, as well as through observational analysis of individual stress distributions. From a biomechanical perspective, critical results in both absolute and percentile values were observed for most variables in the TB group compared with the PS and LP groups. While maximum and minimum principal stresses were similar among groups, differences in intensity and location were found for total and localized von Mises stresses. In addition, the inferior pole of the patella exhibited critical stress conditions across all groups. Conclusions: Tension band wiring demonstrated inferior outcomes compared with locking plates. Biomechanical benefits were observed with the use of two orthogonal locking plates compared with an anterior locking plate; however, both constructs still showed deficiencies in stabilizing the distal pole of the patella. Level of Evidence II; Prospective Study.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 34 (1)
Open AccessBIOMECHANICAL EVALUATION OF FIXATION METHODS IN PATELLAR FRACTURES (AO 34-C3): AN IN VITRO ANALYSIS
Objective: To describe the biomechanical outcomes of five different fixation models, namely: tension band wiring (TB), anterior star-shaped locking plate (PS), lateral orthogonal locking plates (LP), and two additional models using BT and LP combined with a circumferential cerclage wire around the patella, referred to as BTO and PSO, respectively, in a comminuted patellar fracture (AO34C3). Methods: This study analyzed, using the finite element method (FEM), the following variables: total displacement, fragment displacement, maximum and minimum principal stresses, and total and localized von Mises stresses, under loading conditions of 1,500 N (R1) and 3,000 N (R2). Results: Results were presented as absolute values and percentiles, as well as through observational analysis of individual stress distributions. From a biomechanical perspective, critical results in both absolute and percentile values were observed for most variables in the TB group compared with the PS and LP groups. While maximum and minimum principal stresses were similar among groups, differences in intensity and location were found for total and localized von Mises stresses. In addition, the inferior pole of the patella exhibited critical stress conditions across all groups. Conclusions: Tension band wiring demonstrated inferior outcomes compared with locking plates. Biomechanical benefits were observed with the use of two orthogonal locking plates compared with an anterior locking plate; however, both constructs still showed deficiencies in stabilizing the distal pole of the patella. Level of Evidence II; Prospective Study.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 31 (2)
PATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS
Objective: To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks. Methods: From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM). Results: The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was −4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length. Conclusion: In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. Level of Evidence II, Comparative Prospective Study.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 31 (2)
Open AccessPATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS
Objective: To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks. Methods: From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM). Results: The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was −4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length. Conclusion: In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. Level of Evidence II, Comparative Prospective Study.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (2) , e241045
FABREX: A NEW CLINICAL TEST FOR DIAGNOSIS GLUTEAL TENDINOPATHY
Objective: This study aims to describe a simple and accurate semiological method executing a specific maneuver with the lower limb to direct the semiological investigation towards the tendinopathies in the gluteus medius and minimus. Methods: Fifty patients participated in the study, with a mean age of 44.1 ± 13 years, with persistent pain on the side of the hip for more than three months. To compare the FABREX (proposed test) and Lequesne semiological tests, in the diagnosis of tendinopathies in the gluteus medius and minimus, Magnetic Resonance Imaging (MRI) was adopted as the gold standard. Results: FABREX presented high sensitivity and moderate specificity for tendinopathy in the gluteus medius and high sensitivity and specificity for tendinopathy in the gluteus minimus. Conclusion: The proposed test, when positive, can be used to determine the diagnosis of gluteal tendinopathies (high specificity). Moreover, it has high sensitivity, excluding the diagnosis when negative. This study represents the initial step for validating the FABREX test, and can therefore be considered a simple and accurate procedure to identify patients with or without gluteal tendinopathies. Level of Evidence III, Case Control Study.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (2) , e241045
Open AccessFABREX: A NEW CLINICAL TEST FOR DIAGNOSIS GLUTEAL TENDINOPATHY
Objective: This study aims to describe a simple and accurate semiological method executing a specific maneuver with the lower limb to direct the semiological investigation towards the tendinopathies in the gluteus medius and minimus. Methods: Fifty patients participated in the study, with a mean age of 44.1 ± 13 years, with persistent pain on the side of the hip for more than three months. To compare the FABREX (proposed test) and Lequesne semiological tests, in the diagnosis of tendinopathies in the gluteus medius and minimus, Magnetic Resonance Imaging (MRI) was adopted as the gold standard. Results: FABREX presented high sensitivity and moderate specificity for tendinopathy in the gluteus medius and high sensitivity and specificity for tendinopathy in the gluteus minimus. Conclusion: The proposed test, when positive, can be used to determine the diagnosis of gluteal tendinopathies (high specificity). Moreover, it has high sensitivity, excluding the diagnosis when negative. This study represents the initial step for validating the FABREX test, and can therefore be considered a simple and accurate procedure to identify patients with or without gluteal tendinopathies. Level of Evidence III, Case Control Study.