Antonio Bazo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antonio Bazo has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Martín Resano
University of Zaragoza
6 shared publications - Eduardo Bolea-Fernandez
Department of Analytical Chemistry, Aragon Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, 50009, Spain
5 shared publications - Maite Aramendía
Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain
4 shared publications - Ana Rua-Ibarz
University of Zaragoza, Department of Analytical Chemistry, Aragon Institute of Engineering Research (I3A), Zaragoza, 50009, Spain
3 shared publications - Esperanza Garcia-Ruiz
Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain
2 shared publications - Flavio Venancio Nakadi
Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain
2 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (31) , 22977-22987
Direct Characterization of Halogen-Based Microplastics via Single-Event ICP-Mass Spectrometry in Negative-Ion Mode
Halogen-containing microplastics such as polytetrafluoroethylene (PTFE) and poly(vinyl chloride) (PVC) are analytically relevant targets, yet their selective characterization by ICP-MS remains challenging, particularly for fluoropolymers due to the limited formation of F+ in conventional positive-ion mode. Here we introduce negative-ion single-event ICP-MS as a direct strategy for particle-resolved characterization of halogen-containing microplastics by monitoring F– and Cl– on a quadrupole ICP-MS without plasma modifiers or proxy-ion chemistry. PTFE and PVC particle standards were used as well-defined model systems, with scanning electron microscopy (SEM) confirming particle morphology and size distributions. Key acquisition and instrumental conditions governing event detectability were systematically optimized, enabling reliable transient detection at a dwell time of 100 μs. Using a conventional spray-chamber configuration, size detection limits of 1.18 μm (PTFE) and 0.73 μm (PVC) were achieved, improving to 0.68 μm (PTFE) and 0.45 μm (PVC) with a high-efficiency sample introduction system. Quantification strategies for negative-mode operation, including external calibration and transport-efficiency-based workflows, were further assessed. Overall, this work establishes negative-ion mode single-event ICP-MS as a direct platform for fluorine- and chlorine-selective microplastic detection and sizing, expanding the analytical scope of particle-resolved microplastic analysis beyond indirect fluorine detection or carbon-based approaches.
- 28 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (31) , 22977-22987
Open AccessDirect Characterization of Halogen-Based Microplastics via Single-Event ICP-Mass Spectrometry in Negative-Ion Mode
Halogen-containing microplastics such as polytetrafluoroethylene (PTFE) and poly(vinyl chloride) (PVC) are analytically relevant targets, yet their selective characterization by ICP-MS remains challenging, particularly for fluoropolymers due to the limited formation of F+ in conventional positive-ion mode. Here we introduce negative-ion single-event ICP-MS as a direct strategy for particle-resolved characterization of halogen-containing microplastics by monitoring F– and Cl– on a quadrupole ICP-MS without plasma modifiers or proxy-ion chemistry. PTFE and PVC particle standards were used as well-defined model systems, with scanning electron microscopy (SEM) confirming particle morphology and size distributions. Key acquisition and instrumental conditions governing event detectability were systematically optimized, enabling reliable transient detection at a dwell time of 100 μs. Using a conventional spray-chamber configuration, size detection limits of 1.18 μm (PTFE) and 0.73 μm (PVC) were achieved, improving to 0.68 μm (PTFE) and 0.45 μm (PVC) with a high-efficiency sample introduction system. Quantification strategies for negative-mode operation, including external calibration and transport-efficiency-based workflows, were further assessed. Overall, this work establishes negative-ion mode single-event ICP-MS as a direct platform for fluorine- and chlorine-selective microplastic detection and sizing, expanding the analytical scope of particle-resolved microplastic analysis beyond indirect fluorine detection or carbon-based approaches.
- Open Access
- 14 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (43) , 24065-24072
Discrete Entity Analysis via Microwave-Induced Nitrogen Plasma–Mass Spectrometry in Single-Event Mode
In this work, single-event microwave-induced nitrogen plasma-mass spectrometry (single-event MINP-MS) was evaluated for the first time for the analysis of discrete entities such as nanoparticles, biological cells, and microplastics. Nitrogen (N2) effectively overcomes Ar-based polyatomic interferences, enabling (ultra)trace element determination of Fe and Se using their most abundant isotopes, 56Fe (91.66%) and 80Se (49.82%). Iron oxide nanoparticles (Fe2O3 NPs) ranging from 20 to 70 nm were accurately characterized, with excellent agreement with established sizing techniques, such as transmission electron microscopy (TEM) and dynamic light scattering (DLS). A limit of detection (LoD) of 8.6 ag for Fe─equivalent to an LoDsize of 19 nm for Fe2O3─was achieved, which is significantly lower than recent values reported for high-end quadrupole-based ICP-MS. Selenium nanoparticles (SeNPs) of 150 and 250 nm were also accurately characterized, without the N2-based plasma experiencing issues handling relatively large metallic NPs (linearity, R2 = 0.9994). Se-enriched yeast cells (SELM-1 certified reference material) were successfully analyzed via single-cell MINP-MS using external calibration based on SeNPs and a transport efficiency-independent approach. In addition, 2-3 μm polystyrene (PS) and polytetrafluoroethylene (PTFE) were accurately sized by monitoring 12C+, confirming the method's suitability for handling micrometer-sized polymeric materials (microplastics). The average duration of individual events (680 ± 160 μs) suggests that the digestion of individual entities in N2-based plasmas is comparable to that in Ar-based plasmas. These results open new avenues for this instrumentation as an alternative to ICP ionization sources, also in the context of discrete entity analysis.
- 14 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (43) , 24065-24072
Open AccessDiscrete Entity Analysis via Microwave-Induced Nitrogen Plasma–Mass Spectrometry in Single-Event Mode
In this work, single-event microwave-induced nitrogen plasma-mass spectrometry (single-event MINP-MS) was evaluated for the first time for the analysis of discrete entities such as nanoparticles, biological cells, and microplastics. Nitrogen (N2) effectively overcomes Ar-based polyatomic interferences, enabling (ultra)trace element determination of Fe and Se using their most abundant isotopes, 56Fe (91.66%) and 80Se (49.82%). Iron oxide nanoparticles (Fe2O3 NPs) ranging from 20 to 70 nm were accurately characterized, with excellent agreement with established sizing techniques, such as transmission electron microscopy (TEM) and dynamic light scattering (DLS). A limit of detection (LoD) of 8.6 ag for Fe─equivalent to an LoDsize of 19 nm for Fe2O3─was achieved, which is significantly lower than recent values reported for high-end quadrupole-based ICP-MS. Selenium nanoparticles (SeNPs) of 150 and 250 nm were also accurately characterized, without the N2-based plasma experiencing issues handling relatively large metallic NPs (linearity, R2 = 0.9994). Se-enriched yeast cells (SELM-1 certified reference material) were successfully analyzed via single-cell MINP-MS using external calibration based on SeNPs and a transport efficiency-independent approach. In addition, 2-3 μm polystyrene (PS) and polytetrafluoroethylene (PTFE) were accurately sized by monitoring 12C+, confirming the method's suitability for handling micrometer-sized polymeric materials (microplastics). The average duration of individual events (680 ± 160 μs) suggests that the digestion of individual entities in N2-based plasmas is comparable to that in Ar-based plasmas. These results open new avenues for this instrumentation as an alternative to ICP ionization sources, also in the context of discrete entity analysis.
- Open Access
- 22 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (10) , 2673-2681
A novel particle mass calibration strategy for the quantification of AuNPs in single cancer cells via laser ablation ICP-mass spectrometry. A case study
This work proposes a particle mass calibration strategy that is independent of the properties and thickness of the gelatin films used for calibration, thus improving accuracy and repeatability for single-cell laser ablation ICP-MS.
- 22 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (10) , 2673-2681
Open AccessA novel particle mass calibration strategy for the quantification of AuNPs in single cancer cells via laser ablation ICP-mass spectrometry. A case study
This work proposes a particle mass calibration strategy that is independent of the properties and thickness of the gelatin films used for calibration, thus improving accuracy and repeatability for single-cell laser ablation ICP-MS.
- Open Access
- 7 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (26) , 13922-13929
Ions with Ions, Entities with Entities: A Proof-of-Concept Study Using the SELM-1 Yeast Certified Reference Material for Intra- and Extracellular Se Quantification via Single-Cell ICP-Mass Spectrometry
In this work, two novel nanoparticle (NP)-based calibration strategies, external calibration and a relative method, have been explored for single-cell ICP-mass spectrometry (SC-ICP-MS) analysis. The fundamental principle of these methods is to rely on individual entities (well-characterized NPs of the target analyte) for calibration rather than on ionic standard solutions. The performance of the NP-based calibration approaches has been compared to that of the reference method (particle size with AuNP standards). In addition to the intracellular Se content (mass per individual cell), the extracellular Se (dissolved fraction) was also determined directly and simultaneously using the average background from the SC-ICP-MS time-resolved signal. The figures-of-merit of the methods developed have been evaluated by relying on the analysis of the SELM-1 cell-certified reference material, consisting of Se-enriched yeast cells, and certified for its total Se content (intracellular + extracellular Se). All methods successfully determined the Se elemental contents, but an improvement in accuracy and precision was observed for the NP-based methods compared to the reference one. Furthermore, the NP-based methods were found to be less time-consuming, more straightforward, and more user-friendly in terms of calculations. These results open new avenues for calibration in quantitative SC-ICP-MS analysis and call for a fundamental change in the methodology, where the determination of ionic contents is based on the use of ionic standard solutions for calibration, while the determination of elemental contents in discrete micro/nanoentities, such as cells, should ideally be based on calibration using standard entities, thus avoiding the need to calculate a transport efficiency coefficient.
- 7 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (26) , 13922-13929
Open AccessIons with Ions, Entities with Entities: A Proof-of-Concept Study Using the SELM-1 Yeast Certified Reference Material for Intra- and Extracellular Se Quantification via Single-Cell ICP-Mass Spectrometry
In this work, two novel nanoparticle (NP)-based calibration strategies, external calibration and a relative method, have been explored for single-cell ICP-mass spectrometry (SC-ICP-MS) analysis. The fundamental principle of these methods is to rely on individual entities (well-characterized NPs of the target analyte) for calibration rather than on ionic standard solutions. The performance of the NP-based calibration approaches has been compared to that of the reference method (particle size with AuNP standards). In addition to the intracellular Se content (mass per individual cell), the extracellular Se (dissolved fraction) was also determined directly and simultaneously using the average background from the SC-ICP-MS time-resolved signal. The figures-of-merit of the methods developed have been evaluated by relying on the analysis of the SELM-1 cell-certified reference material, consisting of Se-enriched yeast cells, and certified for its total Se content (intracellular + extracellular Se). All methods successfully determined the Se elemental contents, but an improvement in accuracy and precision was observed for the NP-based methods compared to the reference one. Furthermore, the NP-based methods were found to be less time-consuming, more straightforward, and more user-friendly in terms of calculations. These results open new avenues for calibration in quantitative SC-ICP-MS analysis and call for a fundamental change in the methodology, where the determination of ionic contents is based on the use of ionic standard solutions for calibration, while the determination of elemental contents in discrete micro/nanoentities, such as cells, should ideally be based on calibration using standard entities, thus avoiding the need to calculate a transport efficiency coefficient.
- 30 September 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (12) , 2517-2528
High-resolution continuum source graphite furnace molecular absorption spectrometry for the monitoring of Sr isotopes via SrF formation: a case study
A new approach for monitoring Sr isotopes via HR CS GFMAS is described.
- 30 September 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (12) , 2517-2528
High-resolution continuum source graphite furnace molecular absorption spectrometry for the monitoring of Sr isotopes via SrF formation: a case study
A new approach for monitoring Sr isotopes via HR CS GFMAS is described.
- Top Cited PapersOpen Access
- 14 March 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 13 (16) , 4436-4473
Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
- 14 March 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 13 (16) , 4436-4473
Top Cited PapersOpen AccessLiving in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).