Latest Publications
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Camera-Based Blood Pressure Estimation via Windkessel Model and Waveform Features
Blood pressure (BP) is generally regarded as the vital sign most strongly correlated with human health. However, for decades, BP measurement has involved a cuff, which causes discomfort and even carries a risk of infection, given the current prevalence of COVID-19. Some studies address these problems using remote photoplethysmography (rPPG), which has shown great success in heart rate detection. Nevertheless, these approaches are not robust, and few have been evaluated with a sufficiently large dataset. We propose an rPPG-based BP estimation algorithm that predicts BP by leveraging the Windkessel model and hand-crafted waveform characteristics. A waveform processing procedure is presented for the rPPG signals to obtain a robust waveform template and thus extract BP-related features. Redundant and unstable features are eliminated via Monte Carlo simulation and according to their relationship with latent parameters in the Windkessel model. For a comprehensive evaluation, the Chiao Tung Blood Pressure (CTBP) dataset was constructed. The experiment was conducted over a four week period of time to evaluate the validity period of the personalization in our system. On all the data, the proposed method outperforms the benchmark algorithms and yields mean absolute errors of 6.48 mmHg and 5.06 mmHg for SBP and DBP, respectively. The performance achieves a “B” grade according to the validation protocol from the British Hypertension Society for both SBP and DBP.
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Camera-Based Blood Pressure Estimation via Windkessel Model and Waveform Features
Blood pressure (BP) is generally regarded as the vital sign most strongly correlated with human health. However, for decades, BP measurement has involved a cuff, which causes discomfort and even carries a risk of infection, given the current prevalence of COVID-19. Some studies address these problems using remote photoplethysmography (rPPG), which has shown great success in heart rate detection. Nevertheless, these approaches are not robust, and few have been evaluated with a sufficiently large dataset. We propose an rPPG-based BP estimation algorithm that predicts BP by leveraging the Windkessel model and hand-crafted waveform characteristics. A waveform processing procedure is presented for the rPPG signals to obtain a robust waveform template and thus extract BP-related features. Redundant and unstable features are eliminated via Monte Carlo simulation and according to their relationship with latent parameters in the Windkessel model. For a comprehensive evaluation, the Chiao Tung Blood Pressure (CTBP) dataset was constructed. The experiment was conducted over a four week period of time to evaluate the validity period of the personalization in our system. On all the data, the proposed method outperforms the benchmark algorithms and yields mean absolute errors of 6.48 mmHg and 5.06 mmHg for SBP and DBP, respectively. The performance achieves a “B” grade according to the validation protocol from the British Hypertension Society for both SBP and DBP.
- 8 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Facial-Image-Based Blood Pressure Measurement System Without Calibration
Blood pressure (BP) is a major vital sign that is highly correlated with human health. However, for decades BP measurement has involved a cuff, which can be uncomfortable and even carry the risk of infection. The remote photoplethysmography (rPPG) technique has gained great success in heart rate monitoring for tackling these problems. Some studies integrate the pulse transit time (PTT) into the system and ask users put their hand beside their face. A calibration procedure is usually needed for such methods. Other methods measure the BP with several rPPG waveform features or the whole rPPG segment. However, these methods remain inconvenient, and few methods evaluate their algorithm with large enough datasets to be effective. Hence, we propose a calibration-free and facial-image-based blood pressure measurement system which takes a deep neural network as the backbone. Seven physiological indicators are derived and fed into the network together with three-channel rPPG signals. We also propose a novel strategy for training the models. For a fair and complete evaluation, we compile three massive datasets containing 1143 subjects and 2291 data. These datasets were collected under different scenarios: one from a school laboratory and the other two from two hospital departments. On the complete testing data, the proposed approach yields an MAE of 11.54 mmHg for SBP and 8.09 mmHg for DBP, outperforming previous studies.
- 8 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Facial-Image-Based Blood Pressure Measurement System Without Calibration
Blood pressure (BP) is a major vital sign that is highly correlated with human health. However, for decades BP measurement has involved a cuff, which can be uncomfortable and even carry the risk of infection. The remote photoplethysmography (rPPG) technique has gained great success in heart rate monitoring for tackling these problems. Some studies integrate the pulse transit time (PTT) into the system and ask users put their hand beside their face. A calibration procedure is usually needed for such methods. Other methods measure the BP with several rPPG waveform features or the whole rPPG segment. However, these methods remain inconvenient, and few methods evaluate their algorithm with large enough datasets to be effective. Hence, we propose a calibration-free and facial-image-based blood pressure measurement system which takes a deep neural network as the backbone. Seven physiological indicators are derived and fed into the network together with three-channel rPPG signals. We also propose a novel strategy for training the models. For a fair and complete evaluation, we compile three massive datasets containing 1143 subjects and 2291 data. These datasets were collected under different scenarios: one from a school laboratory and the other two from two hospital departments. On the complete testing data, the proposed approach yields an MAE of 11.54 mmHg for SBP and 8.09 mmHg for DBP, outperforming previous studies.