Peter Schillebeeckx
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Schillebeeckx has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Arjan J. M. Plompen
European Commission, Joint Research Centre, Geel, Belgium
2 shared publications A. J. M. Plompen
European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, ‐ 2440 Geel, Belgium
1 shared publicationA. KrásA
European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, ‐ 2440 Geel, Belgium
1 shared publicationAhmed Shama
National Cooperative for the Disposal of Radioactive Waste (Nagra), Switzerland
1 shared publication- Alessandro Borella
Belgian Nucl Res Ctr SCK CEN, Inst Environm Hlth & Safety, Mol, Belgium
1 shared publication Alexey Stankovskiy
Belgian Nuclear Research Centre (SCK CEN), Belgium
1 shared publication
Latest Publications
- Open Access
- 29 April 2022
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 196 (9) , 1125-1145
Blind Benchmark Exercise for Spent Nuclear Fuel Decay Heat
The decay heat rate of five spent nuclear fuel assemblies of the pressurized water reactor type were measured by calorimetry at the interim storage for spent nuclear fuel in Sweden. Calculations of the decay heat rate of the five assemblies were performed by 20 organizations using different codes and nuclear data libraries resulting in 31 results for each assembly, spanning most of the current state-of-the-art practice. The calculations were based on a selected subset of information, such as reactor operating history and fuel assembly properties. The relative difference between the measured and average calculated decay heat rate ranged from 0.6% to 3.3% for the five assemblies. The standard deviation of these relative differences ranged from 1.9% to 2.4%.
- 29 April 2022
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 196 (9) , 1125-1145
Open AccessBlind Benchmark Exercise for Spent Nuclear Fuel Decay Heat
The decay heat rate of five spent nuclear fuel assemblies of the pressurized water reactor type were measured by calorimetry at the interim storage for spent nuclear fuel in Sweden. Calculations of the decay heat rate of the five assemblies were performed by 20 organizations using different codes and nuclear data libraries resulting in 31 results for each assembly, spanning most of the current state-of-the-art practice. The calculations were based on a selected subset of information, such as reactor operating history and fuel assembly properties. The relative difference between the measured and average calculated decay heat rate ranged from 0.6% to 3.3% for the five assemblies. The standard deviation of these relative differences ranged from 1.9% to 2.4%.
- 1 January 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 986, 164718
Peak shape calibration of a Cadmium Zinc Telluride detector and its application for the determination of uranium enrichment
- 1 January 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 986, 164718
Peak shape calibration of a Cadmium Zinc Telluride detector and its application for the determination of uranium enrichment
- Open Access
- 13 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 146, 11036
The13C(n,α0)10Be cross section at 14.3 MeV and 17 MeV neutron energy
At nuclear fusion reactors, CVD diamond detectors are considered an advantageous solution for neutron flux monitoring. For such applications the knowledge of the cross section of neutron-induced nuclear reactions on natural carbon are of high importance. Especially the (n,α0) reactions, yielding the highest energy reaction products, are of relevance as they can be clearly distinguished in the spectrum. The 13C(n,α0)10Be cross section was measured relative to 12C(n,α0)9Be at the Van de Graaff facility of EC-JRC Geel, Belgium, at 14.3 MeV and 17.0 MeV neutron energies. The measurement was performed with an sCVD (single-crystal Chemical Vapor Deposition) diamond detector, where the detector material acted simultaneously as sample and as sensor. A novel data analysis technique, based on pulse-shape discrimination, allowed an efficient reduction of background events. The results of the measurement are presented and compared to previously published values for this cross-section.
- 13 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 146, 11036
Open AccessThe13C(n,α0)10Be cross section at 14.3 MeV and 17 MeV neutron energy
At nuclear fusion reactors, CVD diamond detectors are considered an advantageous solution for neutron flux monitoring. For such applications the knowledge of the cross section of neutron-induced nuclear reactions on natural carbon are of high importance. Especially the (n,α0) reactions, yielding the highest energy reaction products, are of relevance as they can be clearly distinguished in the spectrum. The 13C(n,α0)10Be cross section was measured relative to 12C(n,α0)9Be at the Van de Graaff facility of EC-JRC Geel, Belgium, at 14.3 MeV and 17.0 MeV neutron energies. The measurement was performed with an sCVD (single-crystal Chemical Vapor Deposition) diamond detector, where the detector material acted simultaneously as sample and as sensor. A novel data analysis technique, based on pulse-shape discrimination, allowed an efficient reduction of background events. The results of the measurement are presented and compared to previously published values for this cross-section.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Development of a secondary neutron fluence standard at GELINA
The MetroFission project, a Joint Research Project within the European Metrology Research Program, aims at addressing a number of metrological problems involved in the design of proposed Generation IV nuclear reactors. One of the objectives of this multidisciplinary project is the improvement of neutron cross section measurement techniques in order to arrive at uncertainties as required for the design and safety assessment of new generation power plants and fuel cycles. This objective is in line with the "Uncertainty and target accuracy assessment for innovative systems using recent covariance data evaluations" published by a working party of the OECD Nuclear Energy Agency in 2008. These requests are often very challenging, being at or beyond the state-of-the-art in neutron measurements, which is set by self-normalizing methods and the neutron data standards used at laboratories where the data are measured. A secondary neutron fluence standard has been developed and calibrated at the neutron time-of-flight facility GELINA of the JRC's Institute for Reference Materials and Measurements (IRMM). It consists of a flux monitor, a reference ionization chamber containing a 10B layer and a 235 U layer, and a parallel plate ionization chamber with 8 well characterized 235 U deposits. These devices are used to determine the neutron fluence, based on the well-known neutron induced fission reaction on 235 U. All deposits have been prepared and characterized at the IRMM target preparation lab. The secondary fluence standard at the GELINA facility can be used for reliable determination of the efficiency of fluence measurement devices used in neutron data measurements at IRMM and elsewhere. It is an essential tool to reliably calibrate fluence normalization devices used in neutron time-of-flight cross section measurements.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Development of a secondary neutron fluence standard at GELINA
The MetroFission project, a Joint Research Project within the European Metrology Research Program, aims at addressing a number of metrological problems involved in the design of proposed Generation IV nuclear reactors. One of the objectives of this multidisciplinary project is the improvement of neutron cross section measurement techniques in order to arrive at uncertainties as required for the design and safety assessment of new generation power plants and fuel cycles. This objective is in line with the "Uncertainty and target accuracy assessment for innovative systems using recent covariance data evaluations" published by a working party of the OECD Nuclear Energy Agency in 2008. These requests are often very challenging, being at or beyond the state-of-the-art in neutron measurements, which is set by self-normalizing methods and the neutron data standards used at laboratories where the data are measured. A secondary neutron fluence standard has been developed and calibrated at the neutron time-of-flight facility GELINA of the JRC's Institute for Reference Materials and Measurements (IRMM). It consists of a flux monitor, a reference ionization chamber containing a 10B layer and a 235 U layer, and a parallel plate ionization chamber with 8 well characterized 235 U deposits. These devices are used to determine the neutron fluence, based on the well-known neutron induced fission reaction on 235 U. All deposits have been prepared and characterized at the IRMM target preparation lab. The secondary fluence standard at the GELINA facility can be used for reliable determination of the efficiency of fluence measurement devices used in neutron data measurements at IRMM and elsewhere. It is an essential tool to reliably calibrate fluence normalization devices used in neutron time-of-flight cross section measurements.
- 1 January 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1412 (1) , 121-128
Measurement of Neutron Reaction Cross Sections in Carbon using a Single Crystal Diamond Detector
A single crystal diamond detector was exposed to the quasi mono‐energetic neutron fields in the energy range from 7 MeV to 20.5 MeV produced by the Van de Graaff neutron generator of the EC‐JRC‐IRMM. Pulse Height Spectra (PHS) of the neutron interaction with the diamond (carbon) were recorded in order to derive the experimental response function of this detector to neutrons in view of its use as a compact fast neutron spectrometer. Several peaks produced by outgoing charged particles produced when neutrons interact with carbon were identified using the reaction Q‐values. The corresponding nuclear reactions, such as (n,α), (n,p), (n,d) for different excitation states were identified in the PHS. The analysis of the peaks allows the derivation of some neutron reaction cross sections in carbon. The results are presented in this paper together with the associated uncertainties.
- 1 January 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1412 (1) , 121-128
Measurement of Neutron Reaction Cross Sections in Carbon using a Single Crystal Diamond Detector
A single crystal diamond detector was exposed to the quasi mono‐energetic neutron fields in the energy range from 7 MeV to 20.5 MeV produced by the Van de Graaff neutron generator of the EC‐JRC‐IRMM. Pulse Height Spectra (PHS) of the neutron interaction with the diamond (carbon) were recorded in order to derive the experimental response function of this detector to neutrons in view of its use as a compact fast neutron spectrometer. Several peaks produced by outgoing charged particles produced when neutrons interact with carbon were identified using the reaction Q‐values. The corresponding nuclear reactions, such as (n,α), (n,p), (n,d) for different excitation states were identified in the PHS. The analysis of the peaks allows the derivation of some neutron reaction cross sections in carbon. The results are presented in this paper together with the associated uncertainties.