    Design Study of a Dedicated Head and Neck Cancer PET System

    by Mohan Li, Brett Yockey, Shiva Abbaszadeh

    The tumor-involved regions of head and neck cancer (HNC) have complex anatomical structures and vital physiological roles. As a consequence, there is a need for high sensitivity and high spatial resolution dedicated HNC PET scanner. The purpose of this article is to evaluate and optimize system design that includes detecting materials and geometries. For the detecting material, two scanners with the same two-panel geometry based on cadmium zinc telluride (CZT) and lutetium-yttrium oxyorthosilicate (LYSO) were evaluated. For the system geometry, four CZT scanners with two-panel, lengthened two-panel, four-panel, and full-ring geometries were evaluated. A cylinder phantom with sphere lesions and an XCAT phantom in the head and neck region were simulated. The results showed that the sensitivity of the 40-mm thickness CZT system and the 20-mm thickness LYSO system were comparable. However, the multiple interaction photon events recovery accuracy of the CZT system was about 20% higher. The in-panel and orthogonal-panel spatial resolutions of CZT are 0.58 and 0.74 mm, while those of LYSO are 0.70 and 1.40 mm. For system geometry, the four-panel and full-ring scanners have a higher contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR) than the two-panel and lengthened two-panel scanners. However, a 5-mm lesion in the XCAT phantom was visualized within 6 min in the two-panel system.


  • Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit

    by Mohan Li, Shiva Abbaszadeh

    Depth-of-interaction (DOI) capability is important for achieving high spatial resolution and sensitivity in dedicated organ and small animal positron emission tomography (PET) scanners. The dual-ended readout is one of the common methods that can achieve good DOI resolution. The aim of this study is to evaluate a dual-ended readout detector based on silicon photomultiplier (SiPM) and TOFPET2 application-specific integrated circuit (ASIC). The detector is based on 4 4 lutetium–yttrium oxyorthosilicate (LYSO) units, each unit contained 6 6 LYSO crystals, and the crystal size was 1 1 20 mm 3 . The four lateral surfaces of LYSO crystals were mechanically ground to W14 (surface roughness 10–14 m), and the two ended surfaces were polished (surface roughness 2 and 1.53 (at 420 nm), respectively. To characterize the detector performance at different depths, another 1 25.8 20 mm 3 single LYSO slab was used. Data were acquired at 10 depths (1, 3, …, 19 mm), and each depth had a 10 min acquisition time and about 40 thousand coincidence events. During the experiment, the SiPM temperature was controlled as 27.6 0.4 °C. The results showed that the 1.2 mm light guide offered the best crystal resolvability. The energy, coincidence time, and DOI resolution full-width at half-maximum of the detector were characterized as 15.66% 0.66%, 602.98 10.58 ps, and 2.33 0.07 mm, respectively. The good DOI resolution indicates the potential of utilizing the detector for high-resolution PET applications.