Zifei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zifei Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chunda Zhang
School of Mechanical and Electrical Engineering, Qiqihar University, Qiqihar 161006, China
1 shared publication - Fan Yang
School of electrical and electronic engineering, Harbin University of Science and Technology, Harbin, China
1 shared publication - Fengxia Xu
School of Mechanical and Electrical Engineering, Qiqihar University, Qiqihar, China
1 shared publication - Fengxia Xu
School of Mechanical and Electrical Engineering, Qiqihar University, Qiqihar 161000, China
1 shared publication - Jiwei Li
State Grid Heilongjiang Provincial Electric Power Co., Ltd., Jixi Power Supply Company, Jixi 158100, China
1 shared publication - Lijing Wang
School of Mechanical and Electrical Engineering, Qiqihar University, Qiqihar 161000, China
1 shared publication
Latest Publications
- Open Access
- 28 June 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2855
A Novel Error-Correcting Particle Swarm Optimization Back Propagation Fault Diagnosis Method for Microgrid
Compared to traditional power grids, microgrids have a more flexible operating mode. There are various distributed power sources within the microgrid, and different types of distributed power sources have different control methods. Once a short-circuit fault occurs in the microgrid, these characteristics will increase the difficulty of microgrid fault diagnosis and reduce the accuracy of microgrid fault diagnosis. This paper proposes an error-correcting particle swarm optimization back propagation microgrid fault diagnosis method for the diagnosis of short-circuit faults in microgrids that identifies the accuracy of alarm signals, corrects unreasonable signals, and obtains the correct fault set of the microgrid through the temporal logic relationship between each protection. Using the particle swarm optimization back propagation (PSO-BP) neural network algorithm to train fault alarm signals, fast convergence can be achieved, and accurate diagnostic results can be obtained after the sixth generation training is completed. As this fault diagnosis algorithm is applied to line protection equipment, it can be used to diagnose all types of short-circuit faults. This algorithm is easy to implement and has a small data scale, which is conducive to efficient and concise fault diagnoses in microgrids.
- 28 June 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2855
Open AccessA Novel Error-Correcting Particle Swarm Optimization Back Propagation Fault Diagnosis Method for Microgrid
Compared to traditional power grids, microgrids have a more flexible operating mode. There are various distributed power sources within the microgrid, and different types of distributed power sources have different control methods. Once a short-circuit fault occurs in the microgrid, these characteristics will increase the difficulty of microgrid fault diagnosis and reduce the accuracy of microgrid fault diagnosis. This paper proposes an error-correcting particle swarm optimization back propagation microgrid fault diagnosis method for the diagnosis of short-circuit faults in microgrids that identifies the accuracy of alarm signals, corrects unreasonable signals, and obtains the correct fault set of the microgrid through the temporal logic relationship between each protection. Using the particle swarm optimization back propagation (PSO-BP) neural network algorithm to train fault alarm signals, fast convergence can be achieved, and accurate diagnostic results can be obtained after the sixth generation training is completed. As this fault diagnosis algorithm is applied to line protection equipment, it can be used to diagnose all types of short-circuit faults. This algorithm is easy to implement and has a small data scale, which is conducive to efficient and concise fault diagnoses in microgrids.
- Open Access
Fault Detection for Interval Type-2 T-S Fuzzy Networked Systems via Event-Triggered Control
This paper investigates the event-triggered fault diagnosis (FD) problem for interval type-2 (IT2) Takagi–Sugeno (T-S) fuzzy networked systems. Firstly, an FD fuzzy filter is proposed by using IT2 T-S fuzzy theory to generate a residual signal. This means that the FD filter premise variable needs to not be identical to the nonlinear networked systems (NNSs). The evaluation functions are referenced to determine the occurrence of system faults. Secondly, under the event-triggered mechanism, a fault residual system (FRS) is established with parameter uncertainty, external disturbance and time delay, which can reduce signal transmission and communication pressure. Thirdly, the progressive stability of the fault residual system is guaranteed by using the Lyapunov theory. For the energy bounded condition of external noise interference, the performance criterion is established using linear matrix inequalities. The matrix parameters of the target FD filter are obtained by the convex optimization method. A less conservative fault diagnosis method can be obtained. Finally, the simulation example is provided to illustrate the effectiveness and the practicalities of the proposed theoretical method.
Open AccessFault Detection for Interval Type-2 T-S Fuzzy Networked Systems via Event-Triggered Control
This paper investigates the event-triggered fault diagnosis (FD) problem for interval type-2 (IT2) Takagi–Sugeno (T-S) fuzzy networked systems. Firstly, an FD fuzzy filter is proposed by using IT2 T-S fuzzy theory to generate a residual signal. This means that the FD filter premise variable needs to not be identical to the nonlinear networked systems (NNSs). The evaluation functions are referenced to determine the occurrence of system faults. Secondly, under the event-triggered mechanism, a fault residual system (FRS) is established with parameter uncertainty, external disturbance and time delay, which can reduce signal transmission and communication pressure. Thirdly, the progressive stability of the fault residual system is guaranteed by using the Lyapunov theory. For the energy bounded condition of external noise interference, the performance criterion is established using linear matrix inequalities. The matrix parameters of the target FD filter are obtained by the convex optimization method. A less conservative fault diagnosis method can be obtained. Finally, the simulation example is provided to illustrate the effectiveness and the practicalities of the proposed theoretical method.