Rebekah Gray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rebekah Gray has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Brian N. Fitch
The Ohio State University, Department of Chemistry and Biochemistry, Columbus, Ohio, USA
2 shared publications - Christine Aurigemma
Pfizer Global, Oncology Medicinal Chemistry, San Diego, California, USA
2 shared publications - Martin Beres
Bristol Myers Squibb, Separation and Analysis Technology Team, Lawrenceville, New Jersey, USA
2 shared publications - Michael Brendan Hicks
Merck & Co., Inc., Rahway, USA
2 shared publications - Susan V. Olesik
Department of Chemistry and Biochemistry, The Ohio State University, 100 West 18th Avenue, Columbus, OH 43210, USA
2 shared publications - William Farrell
Pfizer Research & Development, La Jolla, USA
2 shared publications
Latest Publications
- 3 November 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 25 (11) , 1771-1787
Non-targeted identification and semi-quantitation of emerging per- and polyfluoroalkyl substances (PFAS) in US rainwater
High-resolution mass spectrometry was used to screen for emerging per- and polyfluorinated alkyl substances (PFAS) in precipitation samples collected in summer 2019 at seven sites in the United States. We previously quantified the concentration of ten PFAS in the rainwater samples using the method of isotopic dilution (Pike et al., 2021). Nine of these targeted analytes belonged to the U.S. Environmental Protection Agency Regional Screening Level list, herein referred to as EPA-monitored analytes. In this new work, we identify emerging PFAS compounds by liquid chromatography quadrupole time-of-flight mass spectrometry. Several emerging PFAS were detected across all samples, with the most prevalent compounds being C3–C8 hydrogen-substituted perfluorocarboxylic acids (H-PFCAs) and fluorotelomer carboxylic acids (FTCAs). Concentrations of emerging PFAS were in the 10–1000 ng L−1 range (approximately 1–2 orders of magnitude greater than EPA-monitored PFAS) at all sites except Wooster, OH, where concentrations were even higher, with a maximum estimated ΣPFAS of 16 400 ng L−1. The elevated levels of emerging PFAS in the Wooster samples were predominantly even and odd chain-length H-PFCAs and FTCAs comprised of complex mixtures of branched isomers. This unique composition did not match any known manufactured PFAS formulation reported to date, but it could represent thermally transformed by-products emitted by a local point source. Overall, the results indicate that PFAS outside of the standard analyte lists make up a significant and previously unappreciated fraction of contaminants in rainwater collected within the central U.S.—and potentially world-wide—especially in proximity to localized point sources.
- 3 November 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 25 (11) , 1771-1787
Non-targeted identification and semi-quantitation of emerging per- and polyfluoroalkyl substances (PFAS) in US rainwater
High-resolution mass spectrometry was used to screen for emerging per- and polyfluorinated alkyl substances (PFAS) in precipitation samples collected in summer 2019 at seven sites in the United States. We previously quantified the concentration of ten PFAS in the rainwater samples using the method of isotopic dilution (Pike et al., 2021). Nine of these targeted analytes belonged to the U.S. Environmental Protection Agency Regional Screening Level list, herein referred to as EPA-monitored analytes. In this new work, we identify emerging PFAS compounds by liquid chromatography quadrupole time-of-flight mass spectrometry. Several emerging PFAS were detected across all samples, with the most prevalent compounds being C3–C8 hydrogen-substituted perfluorocarboxylic acids (H-PFCAs) and fluorotelomer carboxylic acids (FTCAs). Concentrations of emerging PFAS were in the 10–1000 ng L−1 range (approximately 1–2 orders of magnitude greater than EPA-monitored PFAS) at all sites except Wooster, OH, where concentrations were even higher, with a maximum estimated ΣPFAS of 16 400 ng L−1. The elevated levels of emerging PFAS in the Wooster samples were predominantly even and odd chain-length H-PFCAs and FTCAs comprised of complex mixtures of branched isomers. This unique composition did not match any known manufactured PFAS formulation reported to date, but it could represent thermally transformed by-products emitted by a local point source. Overall, the results indicate that PFAS outside of the standard analyte lists make up a significant and previously unappreciated fraction of contaminants in rainwater collected within the central U.S.—and potentially world-wide—especially in proximity to localized point sources.
- 18 May 2022
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 24 (11) , 4516-4532
Life cycle analysis and sustainability comparison of reversed phase high performance liquid chromatography and carbon dioxide-containing chromatography of small molecule pharmaceuticals
The greenness of a chromatographic separation is typically determined by examining the solvent selection and the quantity of solvent used. Carbon dioxide is often touted as a green alternative to organic solvents typically used in chromatography. However, this claim does not consider the additional instrumentation and energy requirements needed for its use in supercritical fluid chromatography (SFC) compared to alternative methods such as reversed phase (RP) high-performance liquid chromatography (HPLC). This work demonstrates the importance of considering not just the solvent usage but also the instrumental energy consumption especially at the analytical scale where it can account for the majority of the emissions of the system. Two methods that use a more holistic characterization of greenness are life cycle analysis (LCA) and the analytical method greenness score (AMGS). The AMGS calculator is a relatively new method of determining greenness so the result from the AMGS calculator is benchmarked to the LCA results. The greenness of both chromatographic systems are compared at both the analytical and preparative scale for the separation of small molecule drug molecules. In general, SFC separations at low flow rates (−1) performed unfavorably when compared to comparable RP-HPLC separations. The influence of chromatographic conditions for SFC, such as flow rate and higher back pressures, are shown to improve the overall greenness of this technique. SFC separations were in general favorable or at least comparable to the RP-HPLC separations when the SFC separations were faster. Lastly, the electrical energy sources used for instruments were demonstrated to reduce the impact of instrument energy consumption at all scales.
- 18 May 2022
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 24 (11) , 4516-4532
Life cycle analysis and sustainability comparison of reversed phase high performance liquid chromatography and carbon dioxide-containing chromatography of small molecule pharmaceuticals
The greenness of a chromatographic separation is typically determined by examining the solvent selection and the quantity of solvent used. Carbon dioxide is often touted as a green alternative to organic solvents typically used in chromatography. However, this claim does not consider the additional instrumentation and energy requirements needed for its use in supercritical fluid chromatography (SFC) compared to alternative methods such as reversed phase (RP) high-performance liquid chromatography (HPLC). This work demonstrates the importance of considering not just the solvent usage but also the instrumental energy consumption especially at the analytical scale where it can account for the majority of the emissions of the system. Two methods that use a more holistic characterization of greenness are life cycle analysis (LCA) and the analytical method greenness score (AMGS). The AMGS calculator is a relatively new method of determining greenness so the result from the AMGS calculator is benchmarked to the LCA results. The greenness of both chromatographic systems are compared at both the analytical and preparative scale for the separation of small molecule drug molecules. In general, SFC separations at low flow rates (−1) performed unfavorably when compared to comparable RP-HPLC separations. The influence of chromatographic conditions for SFC, such as flow rate and higher back pressures, are shown to improve the overall greenness of this technique. SFC separations were in general favorable or at least comparable to the RP-HPLC separations when the SFC separations were faster. Lastly, the electrical energy sources used for instruments were demonstrated to reduce the impact of instrument energy consumption at all scales.
- 6 May 2022
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 24 (11) , 4504-4515
Improving the environmental hazard scores metric for solvent mixtures containing carbon dioxide for chromatographic separations
Quantifying the greenness of chromatographic separations using CO2 in the mobile phase.
- 6 May 2022
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 24 (11) , 4504-4515
Improving the environmental hazard scores metric for solvent mixtures containing carbon dioxide for chromatographic separations
Quantifying the greenness of chromatographic separations using CO2 in the mobile phase.