Chandan Banerjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chandan Banerjee has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Birinchi Bora
National Institute of Solar Energy
4 shared publications - Arup Dhar
National Institute of Solar Energy
3 shared publications - Deepak Yadav
National Institute of Solar Energy
2 shared publications - Jai Prakash Singh
National Institute of Solar Energy
2 shared publications - Mugala Naveen Kumar
National Institute of Solar Energy
2 shared publications - Ana Belén Cueli
CENER (Spanish Renewable Energy Centre) Navarra Spain
1 shared publication
Latest Publications
- 23 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Assessment of 21-Year Field-Exposed PV Module Performance and Degradation in the Composite Climatic Zones of India
Long-term performance and degradation analysis of photovoltaic modules is critical for defining testing criteria, as well as for evaluating recycling and reuse potential. This study presents the performance and degradation assessment of monocrystalline silicon PV modules that have been field-exposed for 21 years in the composite climatic zones of India. The observed annual power degradation rate ranges from 0.8 % to 4.0 %, surpassing typical warranty limits. Despite this degradation, the analysis indicates considerable potential for reusing PV modules that have experienced up to 25 % performance loss, particularly in secondary use for low voltage applications. Additionally, area requirement analysis at a latitude of 30° shows that accommodating modules with 25 % degradation would require approximately 36 % more land compared to non-degraded modules, an important consideration for project economics and land use planning.
- 23 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Assessment of 21-Year Field-Exposed PV Module Performance and Degradation in the Composite Climatic Zones of India
Long-term performance and degradation analysis of photovoltaic modules is critical for defining testing criteria, as well as for evaluating recycling and reuse potential. This study presents the performance and degradation assessment of monocrystalline silicon PV modules that have been field-exposed for 21 years in the composite climatic zones of India. The observed annual power degradation rate ranges from 0.8 % to 4.0 %, surpassing typical warranty limits. Despite this degradation, the analysis indicates considerable potential for reusing PV modules that have experienced up to 25 % performance loss, particularly in secondary use for low voltage applications. Additionally, area requirement analysis at a latitude of 30° shows that accommodating modules with 25 % degradation would require approximately 36 % more land compared to non-degraded modules, an important consideration for project economics and land use planning.
- 22 May 2023
- Published by Springer Nature
- p. 583-591
Performance Analysis of Bifacial PV Module in Different Climatic Zones of India
- 22 May 2023
- Published by Springer Nature
- p. 583-591
Performance Analysis of Bifacial PV Module in Different Climatic Zones of India
- 24 April 2023
- Published by Springer Nature
- p. 199-207
After Lifetime Reliability and Performance Analysis of PV Modules
- 24 April 2023
- Published by Springer Nature
- p. 199-207
After Lifetime Reliability and Performance Analysis of PV Modules
- Open Access
- 5 May 2022
- Published by Wiley in Progress in Photovoltaics: Research and Applications
- Vol. 30 (11) , 1255-1269
Results from an international interlaboratory study on light‐ and elevated temperature‐induced degradation in solar modules
This paper reports the results of an international interlaboratory comparison study on light‐ and elevated temperature‐induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection and screen a large and diverse set of prototype modules for LETID. Results across labs indicate the reproducibility of LETID testing is likely within ±1% of maximum power (PMP). In intentionally engineered LETID‐sensitive modules, mean degradation after the prescribed detection stress is roughly 6% PMP. In other module types the LETID sensitivity is smaller, and in some we observe essentially negligible degradation attributable to LETID. In LETID‐sensitive modules, both open‐circuit voltage (VOC) and short‐circuit current (ISC) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the estimated loss of cell ISC, which drives loss of module ISC. Overall, this work has helped inform the creation of a forthcoming standard technical specification for LETID testing of PV modules, IEC TS 63342 ED1, and should aid in the interpretation of results from that and other LETID tests.
- 5 May 2022
- Published by Wiley in Progress in Photovoltaics: Research and Applications
- Vol. 30 (11) , 1255-1269
Open AccessResults from an international interlaboratory study on light‐ and elevated temperature‐induced degradation in solar modules
This paper reports the results of an international interlaboratory comparison study on light‐ and elevated temperature‐induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection and screen a large and diverse set of prototype modules for LETID. Results across labs indicate the reproducibility of LETID testing is likely within ±1% of maximum power (PMP). In intentionally engineered LETID‐sensitive modules, mean degradation after the prescribed detection stress is roughly 6% PMP. In other module types the LETID sensitivity is smaller, and in some we observe essentially negligible degradation attributable to LETID. In LETID‐sensitive modules, both open‐circuit voltage (VOC) and short‐circuit current (ISC) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the estimated loss of cell ISC, which drives loss of module ISC. Overall, this work has helped inform the creation of a forthcoming standard technical specification for LETID testing of PV modules, IEC TS 63342 ED1, and should aid in the interpretation of results from that and other LETID tests.
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2510-2517
Efficiency Assessment of BLDC type Solar Water Pumping System fed by Photovoltaic and Grid
This paper optimizes the operation of Brushless DC motor (BLDC) operated solar water pumping system. The proposed system is assisted with single phase supply to ensure the system operation in the high efficiency zone which is governed by the pump. In conventional systems consisting of either AC supply or PV leads to low reliable and inconsistent operation of the motor for water pumping applications. The proposed system consists of Power Factor Correction (PFC) converter for grid input, DC-DC converter as MPPT channel for PV, and three phase inverter to control BLDC type motor-pump set. The entire system is equipped with the control strategy which has multiple modes of operation based on availability of sources. The modelling of all the power converters and their compensator design are provided in this paper. Performance of the system is investigated using developed test-bed with water-pump, tank, power conditioning unit, solar PV simulator, and grid supply. The control strategy and overall system efficiency is verified by simulation and experimental results.
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2510-2517
Efficiency Assessment of BLDC type Solar Water Pumping System fed by Photovoltaic and Grid
This paper optimizes the operation of Brushless DC motor (BLDC) operated solar water pumping system. The proposed system is assisted with single phase supply to ensure the system operation in the high efficiency zone which is governed by the pump. In conventional systems consisting of either AC supply or PV leads to low reliable and inconsistent operation of the motor for water pumping applications. The proposed system consists of Power Factor Correction (PFC) converter for grid input, DC-DC converter as MPPT channel for PV, and three phase inverter to control BLDC type motor-pump set. The entire system is equipped with the control strategy which has multiple modes of operation based on availability of sources. The modelling of all the power converters and their compensator design are provided in this paper. Performance of the system is investigated using developed test-bed with water-pump, tank, power conditioning unit, solar PV simulator, and grid supply. The control strategy and overall system efficiency is verified by simulation and experimental results.
- 1 August 2017
- Published by Elsevier in Optics Communications
- Vol. 397, 1-9
Improvement of photon management in partial rear contact solar cells using a combination of DBR and Mie scatterers
- 1 August 2017
- Published by Elsevier in Optics Communications
- Vol. 397, 1-9
Improvement of photon management in partial rear contact solar cells using a combination of DBR and Mie scatterers