JRJames Riffat

James Riffat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James Riffat has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Instability-Aware Digital Twins for Robust Co-Optimization of Operational Carbon Emissions, Thermal Comfort, and Structural Serviceability Reliability under Uncertainty in Smart Buildings

    by Seyed Reza Samaei, Jarek Kurnitski, James Riffat

    Modern smart buildings operate under continuously varying climatic, occupancy, equipment, grid-carbon, material, degradation, and sensing conditions, making nominal optimization insufficient for reliable operational decision-making. This study develops and numerically evaluates an instability-aware digital twin for robust co-optimization of operational carbon emissions, occupied-zone thermal discomfort, and component-level structural serviceability reliability under uncertainty. The framework combines a multi-rate thermal–energy–moisture–IAQ–structural model, carbon-aware CO₂-based ventilation control, extended Kalman filtering, Monte Carlo uncertainty propagation, FORM and design-point importance sampling, Gaussian-process surrogate modeling, NSGA-II, and dimensionless objective- and decision-instability metrics. A controlled six-zone benchmark represents a six-story office building with a gross floor area of 10,200 m² over a one-year operational horizon and a 20-year reliability horizon. Re-evaluation of the nominally selected P0 policy under the full modeled uncertainty set increased carbon emissions from 42.6 to 50.4 kgCO₂e m⁻² year⁻¹, occupied zone-time discomfort from 115 to 128 K h year⁻¹, and the serviceability limit-state exceedance probability from 0.021 to 0.031. The corresponding nominal-input underestimations were 15.5% for carbon and 32.3% for the exceedance probability. The selected robust policy produced 48.8 kgCO₂e m⁻² year⁻¹, 98 K h year⁻¹, and PSLS = 0.012, with a reliability index of 2.257. Relative to the uncertainty-aware P0 evaluation, it reduced carbon by 3.2%, discomfort by 23.4%, PSLS by 61.3%, and decision instability by 65.7%. The robust policy maintained a mean occupied zone-time CO₂ concentration of 684 ppm, a 99th percentile of 821 ppm, and zero occupied zone-hours above 1,000 ppm. Within the controlled numerical benchmark, the results show that Pareto efficiency alone does not establish operational robustness and that explicit instability quantification materially changes policy selection.

  • Open Access

    An Energy-Data-Anchored Probabilistic Digital-Twin Framework for Coupled Structural–Envelope Degradation and Local Energy-Demand Amplification in Low-Carbon Buildings

    by Seyed Reza Samaei, Assed Naked Haddad, James Riffat

    Long-horizon building-performance models commonly treat operational energy use and physical deterioration as independent processes, despite the potential for envelope degradation to increase thermal demand and for sustained HVAC operation to alter thermal–moisture exposure. This study develops an energy-data-anchored probabilistic digital-twin framework that integrates three coupled lifecycle states: structural/support-condition loss, envelope thermal and leakage loss, and thermal-load memory. A Coupled Structural–Energy Instability Index (CSEI), defined as the spectral abscissa of the frozen local Jacobian, is introduced as a deliberately bounded local modal-transition diagnostic. An autoregressive grey-box observation model was calibrated using 2016 hourly electricity data and independently evaluated one step ahead against the complete 2017 record of a 12,365.4 m2 office building, achieving R2 = 0.933, CV(RMSE) = 6.65%, and NMBE = 0.029%. Within a 25-year, 12,000 m2 reference scenario, bidirectional coupling increased lifecycle electricity consumption and operational carbon emissions by 16.7% and 15.8%, respectively, relative to the energy-decoupled configuration. On the monthly evaluation grid, CSEI first became non-negative at 17.58 years. Across 5,000 parameter–climate realisations, mean lifecycle electricity consumption and carbon emissions were 32.091 GWh and 11.552 ktCO2e, respectively; 98.36% of trajectories crossed the CSEI transition boundary by year 25, with a conditional median onset of 17.67 years. In 100 correctly specified synthetic recovery experiments, median state RMSEs were 0.00205, 0.00121, and 0.00785, and the median absolute onset-reconstruction error was 0.56 years. Collectively, the results provide empirical validation of the energy-observation layer and demonstrate numerical, probabilistic, and inference consistency of the coupled framework. The reported lifecycle trajectories and CSEI onset times remain conditional reference-scenario outputs and should not be interpreted as field-validated deterioration predictions or structural-safety criteria.


  • Open Access

    Uncertainty-Aware Digital Twin Framework for Resilient Low-Carbon Port Infrastructure under Electrification and Sensor Degradation

    by Seyed Reza Samaei, K. S. Reddy, James Riffat

    The electrification of port operations is reshaping the technical relationship between logistics performance, energy demand, infrastructure condition and data reliability. Although digital twins are increasingly used for port monitoring and decision support, many frameworks continue to assume clean sensing, synchronised data streams and stable observability. This study develops an uncertainty-aware digital twin framework for resilient low-carbon port infrastructure under electrification and sensor degradation. A synthetic reference container terminal with 4.5 million TEU/year throughput, six berths, twenty-two quay cranes, 58,000 TEU yard capacity, 120 monitoring channels, 55 MW grid-import capacity, 28 MW renewable capacity and 60 MWh battery storage is simulated for one year at a 5 min update interval. Fifty paired stochastic replications are analysed after a 14-day warm-up period. Under compound stress comprising 35% sensor loss, 5% measurement noise, 10 min synchronisation delay, 90% electrification, 25% higher latent vessel-arrival demand intensity before application of the approach-channel cap, 25% lower renewable availability and 12% lower equipment productivity, the framework yields 10.5 h mean completed-vessel waiting delay, 5.7% energy shortfall, 0.27 infrastructure-health risk, 0.31 uncertainty index, 14.6 h recovery time and a resilience index of 0.64. Relative to a conventional digital twin, completed-vessel waiting delay decreases by 18.0%, energy shortfall by 32.1%, uncertainty index by 29.5% and recovery time by 26.3%. Paired replication-level tests remain significant after Holm adjustment, with large paired effect sizes for the principal operational, energy, uncertainty and resilience outcomes. The results show that resilient electrified-port operation depends not only on installed electrical capacity, but also on temporal alignment, probabilistic state estimation, energy flexibility, health-aware operation and explicit representation of degraded information quality.

  • Open Access

    Instability-Constrained Lifecycle Optimisation of Low-Carbon Buildings under Structural–Envelope Degradation and Energy Feedback

    by Seyed Reza Samaei, Assed Naked Haddad, James Riffat

    Lifecycle retrofit optimisation can favour interventions that perform well in conventional cost–carbon terms while leaving coupled deterioration–energy dynamics insufficiently controlled. This study introduces an instability-constrained lifecycle decision framework that jointly optimises intervention timing, deterioration reset, envelope restoration, and HVAC coefficient-of-performance improvement against expected risk-adjusted lifecycle cost, lifecycle carbon, and the 95% conditional value-at-risk (CVaR95) of cumulative instability exposure. Instability is quantified using a coupled-state eigenvalue indicator (CSEI), which represents positive local modal amplification within the reduced-order deterioration–envelope–energy model and is not a measure of structural failure, code compliance, or physical safety. The framework is demonstrated using a 12,000 m2 office-building reference case anchored to Building Data Genome Project 2 electricity data and evaluated under uncertain degradation and climate conditions using separate training and independent 5,000-scenario out-of-sample evaluation sets. Relative to no intervention, the selected instability-aware strategy reduced expected risk-adjusted lifecycle cost by 23.41%, lifecycle carbon by 6.28%, and mean instability exposure by 99.799%, while persistent instability decreased from 96.38% to 1.60% of scenarios. Cost- and carbon-oriented strategies achieved superior performance in their respective conventional objectives but retained materially greater tail instability, demonstrating that cost and carbon alone do not recover the full lifecycle risk ordering. Across nine deterministic parameter perturbations, the fixed selected package consistently reduced operational carbon and produced no positive nominal CSEI interval through year 25. These findings establish instability-related risk as a distinct and decision-relevant dimension of lifecycle retrofit optimisation, revealing vulnerabilities that conventional cost–carbon assessment can overlook while defining a clear pathway toward monitoring-informed, asset-specific application.


  • Open Access

    Operational-Response-Aware Two-Stage Stochastic Scheduling of Renewable Port Microgrids under Arrival-Driven Congestion and Demand Amplification

    by Seyed Reza Samaei, K. S. Reddy, James Riffat

    Electrified container ports are coupled logistics–energy systems in which uncertain vessel arrivals determine berth occupancy, shore-power activation, cargo-handling intensity, and the residual demand balanced by renewable generation, battery storage, and the utility grid. This study develops a scenario-based stochastic framework linking a non-homogeneous vessel-arrival process to queue-consistent berth occupancy, congestion-responsive demand, photovoltaic and wind uncertainty, battery dispatch, and grid exchange. Physical arrival variability is separated from one-sided delayed Automatic Identification System (AIS) information, while a Gaussian-copula construction preserves adverse traffic–demand–renewable dependence. Five thousand stratified scenarios are reduced to 60 weighted representatives; the conditional extreme-congestion benchmark uses the nine retained Scenario-IV representatives. Across 30 independent paired out-of-sample replications, the proposed schedule reduces operating cost by 13.9% (95% Student-t CI: 13.60–14.20%), grid-import-based operational CO2 emissions by 17.1% (16.76–17.44%), probability-weighted scenario peak grid import by 18.4% (18.03–18.77%), and cumulative operational response by 34.1% (33.50–34.70%) relative to the deterministic reference. Battery throughput is 29.4% lower than under cost-only stochastic dispatch (28.73–30.07%). In the representative seed-2026 benchmark, the corresponding in-sample reductions are 14.8%, 18.2%, 19.9%, and 36.4% relative to B0, while battery throughput is 31.6% lower than under B3. The formulation is an optimistic two-stage perfect-continuous-recourse benchmark rather than a deployable rolling-horizon controller. Within the representative synthetic system, vessel-arrival uncertainty is therefore an operational energy disturbance rather than a purely logistical input.

  • Open Access

    Instability-Aware Digital Twin Control for Grid-Constrained Low-Carbon Smart Ports

    by Seyed Reza Samaei, K. S. Reddy, James Riffat

    Modern smart ports combine terminal electrification, shore power, renewable generation, storage, and digital operational control under uncertain vessel traffic and time-varying grid limits. This study develops a simulation-based digital-twin control prototype that synchronizes vessel flow, berth occupancy, equipment activity, shore-power demand, renewable supply, battery state, grid import, and modelled emissions. A policy-weighted Instability Propagation Index (IPI) classifies lower-stress, critical-transition, and instability-dominated operating regimes and is embedded in an NSGA-II rolling-horizon controller for berth allocation, crane scheduling, vessel sequencing, shore-power timing, flexible loads, renewable curtailment, and battery dispatch. The confirmatory analysis uses a 720-h coupled congestion-and-grid-limit benchmark with 30 paired common-random-number replications, service-preservation controls, terminal-horizon accounting, optimizer-seed verification, and distribution-robust statistics. Relative to operation-focused, energy-focused, and decoupled policies, the proposed controller reduces operational energy by 8.9–21.2%, modelled grid-plus-queue emissions by 8.5–21.0%, peak grid import by 5.7–15.1%, and mean replication-level maximum IPI by 24.8–42.3%, while achieving the lowest composite vessel delay and highest berth-utilization efficiency. A 23 MW renewable portfolio with an 8 MW/16 MWh battery reduces net grid import from 14,510 to 8,370 MWh, peak import from 54.9 to 46.2 MW, modelled emissions from 8,040 to 4,847 tCO₂e, and mean maximum IPI from 0.82 to 0.68. The results demonstrate coordinated logistics–energy control within an externally grounded synthetic benchmark whose principal digital-twin, equipment, and shore-power operating scales are supported by published real-terminal evidence. Deployment at a specific port would nevertheless require local calibration of arrival, service, grid, emission, and control parameters.

  • Open Access

    Physics-Informed Multimodal Sensing and Machine Learning Framework with Real-Time Digital Twin for Intelligent Structural Health Monitoring of Marine Wharves

    by Mohammad Asadian Ghahfarokhi, James Riffat, Seyed Reza Samaei

    Marine wharves, consisting of concrete or steel decks supported by pile foundations, operate in harsh marine environments involving waves, vessel impacts, and corrosive seawater. Even minor cracks or early-stage corrosion in piles can lead to sudden structural failure. Early detection is therefore essential. Traditional vibration-based structural health monitoring (SHM) methods often struggle to deliver reliable results in real operational settings because environmental and operational variations can mask damage-induced frequency changes. This study presents a multimodal SHM framework that integrates accelerometers, strain gauges, high-resolution cameras, acoustic transducers, and corrosion sensors with edge computing, advanced machine learning, and a real-time physics-informed digital twin. Edge nodes preprocess sensor data to extract modal frequencies, crack indicators, and acoustic features, reducing communication loads by over 90% while preserving diagnostic fidelity. A hybrid pipeline combined attention-based multimodal fusion, XGBoost screening, and a feedforward deep neural network trained using a composite physics-informed objective. The physical loss numerically penalised positive damage-related modal-frequency shifts after environmental and operational condition compensation and stiffness ratios outside the admissible range of 0.70–1.00. The selected physics-loss coefficients were λphys = 0.10 and η = 0.50. Sensor features were ingested continuously, whereas finite-element state updates were event-triggered by a fused damage probability of at least 0.80, agreement between at least two sensing modalities, normalised predictive entropy not exceeding 0.35, and persistence over three consecutive 10-s analysis windows. Validation using 200 finite-element simulations and 40 scaled laboratory tests achieved 95.0% accuracy for single-damage detection, compared with 78.0% for the conventional Modal Strain Energy method. For multiple-damage cases, the proposed framework achieved 92.17% precision, 88.33% recall, and an F1-score of 90.21%. Damage-severity estimation yielded R² = 0.891 and an RMSE of 2.06 percentage points, while the mean full-scale-equivalent localisation error was 4.8 cm. Edge processing reduced communication volume by 94.73% without a statistically significant reduction in diagnostic accuracy. While evaluated under controlled conditions, the framework shows strong potential for proactive, accurate, and interpretable monitoring of marine wharves in operational environments.

  • Open Access

    A Reliability-Based Framework for Phase Change Material Thermal Energy Storage under Renewable Intermittency: Linking Phase-Change Dynamics, Energy Availability and Load Matching

    by James Riffat, Seyed Reza Samaei

    Phase change material (PCM)-based thermal energy storage is widely recognized as a key technology for integrating intermittent renewable energy into energy systems. However, most existing studies evaluate performance using temperature- or heat-transfer-based indicators, which do not directly quantify the system’s ability to meet time-dependent energy demand. This limitation becomes critical under realistic renewable operating conditions, where temporal mismatch between supply and demand governs system performance. This study develops a reliability-oriented evaluation framework for PCM-based thermal energy storage under intermittent renewable forcing. The model is applied to an n-octadecane storage system subjected to three forcing scenarios with identical daily input energy (103.13 kJ) and increasing fluctuation intensity (σ = 0.00, 0.20, 0.40). The results show that increasing intermittency leads to a systematic degradation in system performance, with ERI decreased by 10.5%, while LMI declined by 14.0% under strong intermittency and LMI decreasing from 0.931 to 0.801. At the same time, the unmet-energy deficit increased by approximately 5.10 kJ, while the critical duration of unmet demand extends from 2.1 h to 5.6 h. Despite nearly identical final liquid fraction values (0.933 to 0.904), the system exhibits significantly different reliability characteristics, highlighting the limitation of conventional thermal indicators. The results demonstrate that temporal variability affects not only the magnitude of stored energy but also its availability during critical demand periods. The proposed framework establishes a direct link between internal phase-change behavior and system-level energy reliability, providing a physically consistent basis for evaluating and designing thermal energy storage systems under intermittent renewable conditions.


  • Open Access

    Computational Fluid Dynamics in Hybrid Passive–Active Heat Recovery Systems for High-Performance Buildings: A Critical Review

    by James Riffat, Seyed Reza Samaei

    Hybrid passive–active heat recovery systems are increasingly used in high-performance buildings as a practical response to the growing pressure for lower energy use and more stable indoor environmental conditions. These systems combine passive heat transfer elements, such as heat pipes, with limited mechanical ventilation support in order to balance energy efficiency with operational controllability. As a result, they occupy a middle ground between fully passive solutions, which are often sensitive to boundary conditions, and fully active systems, which tend to impose higher energy and operational costs. Computational Fluid Dynamics (CFD) has become the main analytical approach for studying the behaviour of these hybrid systems. It is commonly used to investigate airflow patterns, heat transfer processes, pressure losses, and ventilation effectiveness under a wide range of operating conditions. At the same time, the existing literature shows substantial variation in how CFD models are constructed and applied. Differences in turbulence modelling, boundary condition definition, validation strategy, and performance metrics make it difficult to compare results across studies or draw general conclusions. This review critically examines published CFD-based studies on hybrid passive–active heat recovery systems in high-performance buildings. The focus is not on individual case studies, but on identifying recurring modelling practices, common simplifications, and their implications for predicted system performance. Particular attention is given to the treatment of mixed-mode ventilation, conjugate heat transfer, and the interaction between passive components and mechanically assisted airflow. The review also highlights areas where current CFD practice remains limited, including validation against field measurements and representation of climate-driven variability. By consolidating these findings, the paper aims to clarify the role of CFD as a supporting analytical tool for design and retrofit decisions, rather than as a stand-alone predictor of system performance.


  • Open Access

    Field-Validated Digital Twin–Enabled Structural Health Monitoring for Offshore High-Pile Wharves

    by Seyed Reza Samaei, James Riffat

    Offshore high-pile wharves operate under harsh, variable loads that can mask the earliest signs of deterioration. We present a closed-loop structural health monitoring (SHM) framework that couples multimodal machine/deep learning with a physics-based digital twin (DT). A year-long field deployment at an operating high-pile wharf in Western Asia instrumented six piles with triaxial accelerometers and strain gauges (GPS-synchronized, 100 Hz). After quality control and environmental/operational variability normalization, an unsupervised VAE produces an anomaly score that is fused with a CNN–GNN classifier to yield window-level damage probabilities and pile-by-elevation localization. The DT assimilates these diagnostics through weighted least squares and an EKF, with measurement covariance derived from model uncertainty; “what-if” simulations quantify the structural consequence of candidate repairs. Under chronological splits with leave-one-pile-out, the framework achieves F1 = 0.95 and AUC-ROC = 0.98, with false-alarm rate ≈ 2–5 % and median detection latency ≈ 45 s. Spatial heatmaps consistently pinpoint the affected elevation, while online updating reduces mean frequency bias from ≈ 4.8 % to ≈ 0.9 % and increases mode-shape MAC from ≈ 0.81 to ≥ 0.92. First-mode shifts of ≈ 3–4 % observed in the field are reproduced by DT “stiffness-restoration” scenarios, enabling risk-informed maintenance planning. Compared on identical normalized windows, the proposed method outperforms classical vibration-based indices in both discrimination and false-alarm control. The results demonstrate a scalable, explainable pathway to predictive asset management for critical maritime infrastructure. Beyond structural safety, the proposed framework contributes to sustainable port operation by enabling condition-based maintenance, reducing unnecessary inspections, extending asset service life, and lowering the embodied carbon associated with premature repair or replacement.