Yukun Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yukun Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
10 shared publications - Houxian Du
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing, China
8 shared publications - Biqian Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
6 shared publications - Xunbo Gao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
5 shared publications - Yuan Wang
College of Engineering, Peking University, Beijing, China
5 shared publications - Daiyuan Yang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
4 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
A Gold Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
A Gold Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 2038-2045
Photothermal Detection of Trace Acetylene for Transformer DGA Monitoring Using an Adiabatically Tapered Optical Fiber
In the field of optical sensing of characteristic defect gas in transformers, hollow-core photonic crystal fiber (HC-PCF) gas cells suffer from high fabrication costs and complex manufacturing processes. Meanwhile, fabricating non-adiabatic tapered fiber gas cells requires precise control of geometric parameters, such as the length of the transition region and the waist diameter. Moreover, these structures inherently exhibit common-path interference, making them susceptible to environmental noise and limiting detection sensitivity. To address these issues, we proposed a low-cost and easily fabricated adiabatic tapered fiber gas cell, fabricated from standard single-mode fiber using a flame-brushing tapering technique. We fabricated the adiabatic tapered fibers with a waist diameter of 2.2 μm by optimizing the stretching speed and distance of the stepper motors, effectively avoiding the common-path interference caused by mode coupling in non-adiabatic tapered fibers. This process is simple and achieves a production cost that is only 1% of HC-PCF gas cells. Additionally, we developed a heterodyne Mach–Zehnder interferometric (MZI) sensing system for hydrocarbon detection. We moved the beat frequency carrier signal to 100 MHz by introducing an acousto-optic modulator (AOM) to shift the reference light frequency, significantly reducing low-frequency environmental noise disturbances on both the sensing and reference arms. Based on this system, we achieved a detection limit of 0.6 ppm for acetylene gas, with a linear correlation coefficient (R²) of 0.996 for the sensor response. This sensing approach provides a highly sensitive and low-cost technical solution for the real-time, online monitoring of acetylene gas in power transformers.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 2038-2045
Photothermal Detection of Trace Acetylene for Transformer DGA Monitoring Using an Adiabatically Tapered Optical Fiber
In the field of optical sensing of characteristic defect gas in transformers, hollow-core photonic crystal fiber (HC-PCF) gas cells suffer from high fabrication costs and complex manufacturing processes. Meanwhile, fabricating non-adiabatic tapered fiber gas cells requires precise control of geometric parameters, such as the length of the transition region and the waist diameter. Moreover, these structures inherently exhibit common-path interference, making them susceptible to environmental noise and limiting detection sensitivity. To address these issues, we proposed a low-cost and easily fabricated adiabatic tapered fiber gas cell, fabricated from standard single-mode fiber using a flame-brushing tapering technique. We fabricated the adiabatic tapered fibers with a waist diameter of 2.2 μm by optimizing the stretching speed and distance of the stepper motors, effectively avoiding the common-path interference caused by mode coupling in non-adiabatic tapered fibers. This process is simple and achieves a production cost that is only 1% of HC-PCF gas cells. Additionally, we developed a heterodyne Mach–Zehnder interferometric (MZI) sensing system for hydrocarbon detection. We moved the beat frequency carrier signal to 100 MHz by introducing an acousto-optic modulator (AOM) to shift the reference light frequency, significantly reducing low-frequency environmental noise disturbances on both the sensing and reference arms. Based on this system, we achieved a detection limit of 0.6 ppm for acetylene gas, with a linear correlation coefficient (R²) of 0.996 for the sensor response. This sensing approach provides a highly sensitive and low-cost technical solution for the real-time, online monitoring of acetylene gas in power transformers.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Ultrasonic Fiber-Optic Sensor With Graphene-Silver Composite Diaphragm for Transformer Monitoring
In the field of optical ultrasonic sensing for transformers, probe-type sensors face challenges such as limited sensitivity. In this study, we proposed a fiber optic ultrasonic sensor with a composite diaphragm structure. Based on the design of the sensing membrane and cavity structure, the system achieved highly sensitive ultrasonic sensing suitable for transformer tank applications. A graphene-silver composite film (20 nm/200 nm) served as the sensing diaphragm, while insulating materials formed a compact ultrasonic probe. The cavity length of the probe was meticulously optimized to ensure optimal performance. The transducer’s performance was experimentally evaluated in transformer oil. Results showed that it maintained stable performance, achieving a minimum detectable pressure of 3.8 mPa and an ultrasonic sensitivity of 802.2 nm/kPa. The proposed device exhibited superior average sensitivity and frequency response compared with conventional piezoelectric transducers over a broad frequency range of 20-300 kHz. Its compact structure, immunity to electromagnetic interference, and real-time demodulation capability offered an innovative solution for ultrasonic inspection of power transformers.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Ultrasonic Fiber-Optic Sensor With Graphene-Silver Composite Diaphragm for Transformer Monitoring
In the field of optical ultrasonic sensing for transformers, probe-type sensors face challenges such as limited sensitivity. In this study, we proposed a fiber optic ultrasonic sensor with a composite diaphragm structure. Based on the design of the sensing membrane and cavity structure, the system achieved highly sensitive ultrasonic sensing suitable for transformer tank applications. A graphene-silver composite film (20 nm/200 nm) served as the sensing diaphragm, while insulating materials formed a compact ultrasonic probe. The cavity length of the probe was meticulously optimized to ensure optimal performance. The transducer’s performance was experimentally evaluated in transformer oil. Results showed that it maintained stable performance, achieving a minimum detectable pressure of 3.8 mPa and an ultrasonic sensitivity of 802.2 nm/kPa. The proposed device exhibited superior average sensitivity and frequency response compared with conventional piezoelectric transducers over a broad frequency range of 20-300 kHz. Its compact structure, immunity to electromagnetic interference, and real-time demodulation capability offered an innovative solution for ultrasonic inspection of power transformers.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (3) , 1751-1760
In Situ Detection of Transformer Oil-Dissolved Trace Hydrogen Using a Composite Membrane-Modified Fiber-Optic Fabry--Pérot Probe
When discharge faults occur inside transformers, hydrogen (H2) gas is generated and dissolves into the insulating oil. However, conventional dissolved gas analysis (DGA) techniques cannot achieve in situ detection, and existing fiber-optic sensors lack sufficient detection limits. To enable in situ detection of transformer oil-dissolved trace H2, this work proposes a fiber-optic Fabry-Pérot (F-P) probe based on a composite membrane. The F-P cavity is fabricated by microassembling a single-mode fiber and a ceramic insert, and an ultrathin graphene membrane is transferred onto the cavity end-face as a support layer, followed by deposition of a Pd-Ag alloy as the H2-sensitive layer and pure Pd as the protective layer. Gas-phase H2 detection and in situ oil-dissolved H2 detection experiments are conducted using the fabricated fiber-optic F-P sensor. Results demonstrate that, in gas-phase environments with H2 concentrations ranging from 0 to 167 ppm, the sensor exhibits a sensitivity of 18.5 pm/ppm and a detection limit of 0.14 ppm, with a response time of 6 minutes. When directly immersed in transformer oil, the sensor achieves a sensitivity of 89.7 pm/ppm and a detection limit of 0.08 ppm for oil-dissolved H2 concentrations between 0 and 79.1 ppm. Furthermore, excellent recovery and selectivity performance are verified. Therefore, the fiber-optic F-P H2 sensor proposed in this work enables high-performance in situ detection of oil-dissolved H2 at sub-100 ppb levels.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (3) , 1751-1760
In Situ Detection of Transformer Oil-Dissolved Trace Hydrogen Using a Composite Membrane-Modified Fiber-Optic Fabry--Pérot Probe
When discharge faults occur inside transformers, hydrogen (H2) gas is generated and dissolves into the insulating oil. However, conventional dissolved gas analysis (DGA) techniques cannot achieve in situ detection, and existing fiber-optic sensors lack sufficient detection limits. To enable in situ detection of transformer oil-dissolved trace H2, this work proposes a fiber-optic Fabry-Pérot (F-P) probe based on a composite membrane. The F-P cavity is fabricated by microassembling a single-mode fiber and a ceramic insert, and an ultrathin graphene membrane is transferred onto the cavity end-face as a support layer, followed by deposition of a Pd-Ag alloy as the H2-sensitive layer and pure Pd as the protective layer. Gas-phase H2 detection and in situ oil-dissolved H2 detection experiments are conducted using the fabricated fiber-optic F-P sensor. Results demonstrate that, in gas-phase environments with H2 concentrations ranging from 0 to 167 ppm, the sensor exhibits a sensitivity of 18.5 pm/ppm and a detection limit of 0.14 ppm, with a response time of 6 minutes. When directly immersed in transformer oil, the sensor achieves a sensitivity of 89.7 pm/ppm and a detection limit of 0.08 ppm for oil-dissolved H2 concentrations between 0 and 79.1 ppm. Furthermore, excellent recovery and selectivity performance are verified. Therefore, the fiber-optic F-P H2 sensor proposed in this work enables high-performance in situ detection of oil-dissolved H2 at sub-100 ppb levels.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 11092-11101
A Low-Cost and High-Stability Demodulation Method for Photothermal Spectroscopy Gas Detection in Power Transformer
Dissolved gas analysis is a critical component of transformer defect diagnosis. Oil-dissolved gas sensing based on fiber-optic photothermal spectroscopy was proposed for it is immune for electromagnetic interfere. Traditional methods apply sinusoidal modulation to the pump light wavelength. However, sinusoidal phase noise is also generated in the absence of gas due to the laser absorption by fiber splice points, flanges, and other components. This noise makes it difficult to further lower the detection limit. In this paper, a pump light frequency modulation method combining a sine wave with a sawtooth wave was introduced. The gas concentration was determined by detecting the amplitude of the second harmonic wave, which addressed the aforementioned issues. However, these systems are highly sensitive to temperature, vibrations, and other factors, leading to poor stability. Additionally, the industry application is limited by the high cost of the demodulation system. Thus, this paper proposed an acetylene sensing topology based on heterodyne interference and Mach–Zehnder interferometric structure. The sensing phase signal was modulated by a 100 MHz modulation, achieved by introducing an acousto-optic modulator (AOM) into the reference arm, which reduced low-frequency noise interference. Then, a low-cost demodulation method was also proposed based on mixing and down-conversion. This method lowered the carrier frequency from 100 MHz to 100 kHz, reducing demodulation costs by about 91%. The proposed photothermal spectroscopy gas detection system achieved a detection limit of 0.256 ppm for acetylene.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 11092-11101
A Low-Cost and High-Stability Demodulation Method for Photothermal Spectroscopy Gas Detection in Power Transformer
Dissolved gas analysis is a critical component of transformer defect diagnosis. Oil-dissolved gas sensing based on fiber-optic photothermal spectroscopy was proposed for it is immune for electromagnetic interfere. Traditional methods apply sinusoidal modulation to the pump light wavelength. However, sinusoidal phase noise is also generated in the absence of gas due to the laser absorption by fiber splice points, flanges, and other components. This noise makes it difficult to further lower the detection limit. In this paper, a pump light frequency modulation method combining a sine wave with a sawtooth wave was introduced. The gas concentration was determined by detecting the amplitude of the second harmonic wave, which addressed the aforementioned issues. However, these systems are highly sensitive to temperature, vibrations, and other factors, leading to poor stability. Additionally, the industry application is limited by the high cost of the demodulation system. Thus, this paper proposed an acetylene sensing topology based on heterodyne interference and Mach–Zehnder interferometric structure. The sensing phase signal was modulated by a 100 MHz modulation, achieved by introducing an acousto-optic modulator (AOM) into the reference arm, which reduced low-frequency noise interference. Then, a low-cost demodulation method was also proposed based on mixing and down-conversion. This method lowered the carrier frequency from 100 MHz to 100 kHz, reducing demodulation costs by about 91%. The proposed photothermal spectroscopy gas detection system achieved a detection limit of 0.256 ppm for acetylene.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Enhanced Detection of SF₆ Gas Moisture Concentration in Gas-Insulated Switchgear Utilizing Tilted Fiber Bragg Grating Coated With Multilayer Graphene Oxide Films
The increase in moisture concentration within Gas Insulated Switchgear (GIS) reduces the insulation level of the equipment, necessitating the detection of SF 6 moisture concentration. Addressing the challenge of the traditional dew point method being impractical for in-situ and long-term online operation, this study proposed a fiber moisture sensor based on tilted fiber Bragg grating (TFBG) coated with multilayer graphene oxide (GO) films. An improved method of heat deposition coating was developed to achieve multi-layer deposition of GO on the TFBG surface. By increasing the number of coating layers, the sensitivity of moisture detection was enhanced. An experimental platform for SF 6 moisture detection was established to validate the sensitivity, hysteresis, and repeatability of the proposed moisture sensor. The results indicated that the sensor exhibited a response time of 6 min, with a moisture detection range of 13 ppm to 1081 ppm. Within the linear response range, the sensitivity reached 8.6 pm/100ppm. Additionally, the sensor demonstrated good hysteresis, repeatability, and reliability. Thus, the proposed fiber moisture sensor in this paper enables in-situ detection of SF 6 gas within GIS.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Enhanced Detection of SF₆ Gas Moisture Concentration in Gas-Insulated Switchgear Utilizing Tilted Fiber Bragg Grating Coated With Multilayer Graphene Oxide Films
The increase in moisture concentration within Gas Insulated Switchgear (GIS) reduces the insulation level of the equipment, necessitating the detection of SF 6 moisture concentration. Addressing the challenge of the traditional dew point method being impractical for in-situ and long-term online operation, this study proposed a fiber moisture sensor based on tilted fiber Bragg grating (TFBG) coated with multilayer graphene oxide (GO) films. An improved method of heat deposition coating was developed to achieve multi-layer deposition of GO on the TFBG surface. By increasing the number of coating layers, the sensitivity of moisture detection was enhanced. An experimental platform for SF 6 moisture detection was established to validate the sensitivity, hysteresis, and repeatability of the proposed moisture sensor. The results indicated that the sensor exhibited a response time of 6 min, with a moisture detection range of 13 ppm to 1081 ppm. Within the linear response range, the sensitivity reached 8.6 pm/100ppm. Additionally, the sensor demonstrated good hysteresis, repeatability, and reliability. Thus, the proposed fiber moisture sensor in this paper enables in-situ detection of SF 6 gas within GIS.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2924-2932
Measurement and Analysis of the Switching Transients in 500 kV Pumped Storage Power Plants
Pumped storage power plants (PSPPs) are among the most efficient and practical large-scale energy storage systems. In recent years, several transformer failures have occurred in PSPPs, and transient overvoltage is considered a potential reason for failure. However, there is a lack of field measurement results for transient analysis. In this paper, a switching transient measurement system and multipoint synchronous triggering system were developed. Field measurements were carried out in three PSPPs. According to the measurement results, the maximum amplitude of the switching overvoltage was 630.6±46.5 kV. The shortest front time was 76±7.6 ns. The largest steepness was 1130±140.8 kV/μs. A simulation model was built to analyze three phenomena in the transient, including multistep waveform, overvoltage peak, and power transformer demagnetization. The measurement and analysis results are beneficial for the improvement of simulation modeling. It is helpful to pinpoint potentially damaging transients for equipment manufacturers and designers of PSPPs.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2924-2932
Measurement and Analysis of the Switching Transients in 500 kV Pumped Storage Power Plants
Pumped storage power plants (PSPPs) are among the most efficient and practical large-scale energy storage systems. In recent years, several transformer failures have occurred in PSPPs, and transient overvoltage is considered a potential reason for failure. However, there is a lack of field measurement results for transient analysis. In this paper, a switching transient measurement system and multipoint synchronous triggering system were developed. Field measurements were carried out in three PSPPs. According to the measurement results, the maximum amplitude of the switching overvoltage was 630.6±46.5 kV. The shortest front time was 76±7.6 ns. The largest steepness was 1130±140.8 kV/μs. A simulation model was built to analyze three phenomena in the transient, including multistep waveform, overvoltage peak, and power transformer demagnetization. The measurement and analysis results are beneficial for the improvement of simulation modeling. It is helpful to pinpoint potentially damaging transients for equipment manufacturers and designers of PSPPs.
- 12 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
A Relative Humidity Sensor Based on Non-Adiabatic Tapered Optical Fiber for Remote Measurement in Power Cable Tunnel
To solve the power supply, signal communication, and lifetime problems in the humidity sensing in power cable tunnel, an intrinsic non-adiabatic tapered optical fiber (NATOF) relative humidity (RH) sensor without functional film was proposed in this article. The sensing principle based on multimode interference and refractive index (RI) sensitivity was introduced. The relationship between humidity sensitivity and the waist diameter of NATOF was theoretically analyzed to improve the sensor sensitivity. It is found that high relative humidity sensitivity detection can be achieved by taking advantage of the NATOF’s high sensitivity near the dispersion turning point (DTP). The test-obtained trends of the humidity sensitivity at different waist diameters were consistent with the theoretical results. The proposed NATOF sensor with a waist diameter of 2.39 $\mu \text{m}$ had a linear response in the range of 35%–90% RH, a detection distance of over 10 km, a relative humidity sensitivity of −47 pm/% RH, and an accuracy of ±4.6% RH. Based on the different response sensitivities to humidity and temperature of different dips, a sensing matrix was established to solve the temperature cross-sensitivity issue of the relative humidity sensor.
- 12 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
A Relative Humidity Sensor Based on Non-Adiabatic Tapered Optical Fiber for Remote Measurement in Power Cable Tunnel
To solve the power supply, signal communication, and lifetime problems in the humidity sensing in power cable tunnel, an intrinsic non-adiabatic tapered optical fiber (NATOF) relative humidity (RH) sensor without functional film was proposed in this article. The sensing principle based on multimode interference and refractive index (RI) sensitivity was introduced. The relationship between humidity sensitivity and the waist diameter of NATOF was theoretically analyzed to improve the sensor sensitivity. It is found that high relative humidity sensitivity detection can be achieved by taking advantage of the NATOF’s high sensitivity near the dispersion turning point (DTP). The test-obtained trends of the humidity sensitivity at different waist diameters were consistent with the theoretical results. The proposed NATOF sensor with a waist diameter of 2.39 $\mu \text{m}$ had a linear response in the range of 35%–90% RH, a detection distance of over 10 km, a relative humidity sensitivity of −47 pm/% RH, and an accuracy of ±4.6% RH. Based on the different response sensitivities to humidity and temperature of different dips, a sensing matrix was established to solve the temperature cross-sensitivity issue of the relative humidity sensor.