XLXiaoxi Liu

Xiaoxi Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaoxi Liu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open‐source implementation of X‐nuclear sequences using the Pulseq framework

    by Xiaoxi Liu, Di Cui, Peder E. Z. Larson, Dirk Mayer, Andreas Korzowski, Jon‐Fredrik Nielsen, Rolf F. Schulte, Changhua Mu, Lucas Carvajal, Duan Xu, et al.

    Purpose: Create vendor‐neutral modular sequences for X‐nuclear acquisitions and build an X‐nuclear–enabled Pulseq interpreter for GE (GE HealthCare, Waukesha, WI) scanners. Methods: We designed a modular 2D gradient echo spiral sequence to support several sequence formats and a modular metabolite‐specific 3D balanced steady‐state free precession sequence for hyperpolarized (HP) carbon‐13 ( 13 C) MRI. In addition, we developed a new Pulseq interpreter for GE scanners, named TOPPE MNS (TOPPE Multi‐Nuclear Spectroscopy), to implement X‐nuclear acquisitions capabilities. We evaluated TOPPE MNS and the modular sequences through phantom studies using phosphorus‐31 ( 31 P), hydrogen‐2 ( 2 H), and 13 C coils, and in vivo studies including a human brain deuterium metabolic imaging study at natural abundance, HP 13 C animal studies, and human renal studies. Results: Data from the 13 C phantom showed the accuracy of designed modular sequences and consistent performance with the product sequences. 31 P, 2 H, and 13 C phantom studies and a multi‐vendor/multi‐version 13 C phantom study showed accurate excitation and spatial encoding functionalities. A 2 H‐MRS brain volunteer study, HP [1‐ 13 C]pyruvate animal study, and human renal study showed good image quality with SNR comparable to those reported in the published literature. These results demonstrated the reproducibility of the TOPPE MNS GE interpreter and modular spiral sequences. Conclusion: We have designed a modular 2D gradient echo spiral sequence supporting several sequence formats and a modular metabolic‐specific 3D balanced steady‐state free precession sequence for 13 C acquisition, as well as developed a GE interpreter with X‐nucleus capabilities. Our work paves the way for future multi‐site studies with acquisitions for X‐nuclei across MRI vendors and software versions.


  • Open Access

    A flexible MRF approach to improve kinetic rate estimation with bSSFP ‐based hyperpolarized [1‐ 13 C ]pyruvate MRI

    by Anna Bennett Haller, Xiaoxi Liu, Avantika Sinha, Sule Sahin, Peder E. Z. Larson, Charlie Yi Wang

    Purpose: In this work, we adopt the MR fingerprinting (MRF) framework and leverage its flexibility in quantitative pulse sequence design to propose improved balanced steady‐state free precession (bSSFP)–based hyperpolarized Carbon‐13 ( 13 C) acquisitions for robust metabolic conversion rate quantification. Methods: Spectrally selective bSSFP‐based acquisitions with variable RF excitation were implemented for [1‐ 13 C]pyruvate and used in conjunction with prior implementation of [1‐ 13 C]lactate selective bSSFP imaging. MRF framework parameter estimation was performed using dictionary‐based template matching. Influences of bSSFP‐based acquisitions and sigmoid RF excitation scheme were assessed with simulation experiments and Monte Carlo evaluation. Methods were then compared using experimental data from rat kidney acquired on a clinical 3 T scanner. Results: Simulations indicated that combining bSSFP‐based acquisitions and variable RF excitation (MRF‐Sigmoid) exhibited bias PL ) and noise level investigated when estimating k PL with the MRF framework. bSSFP‐based experiments, with and without sigmoid excitation scheme, showed lower variance in fits at all levels of k PL and noise investigated compared to the method used in prior work by this group (hybrid gradient echo). Positive, linear correlations were found for in vivo voxel‐wise estimates of k PL in healthy rat kidneys when comparing all experiment methods. MRF‐Sigmoid experiment design increased pyruvate cumulative SNR by 3.5‐fold over hybrid gradient echo while maintaining similar lactate cumulative SNR. Conclusion: The use of the MRF framework for k PL estimation demonstrates the feasibility of dictionary‐based template matching and can be used to accurately estimate physiologically relevant k PL and improve cumulative SNR.

  • Time‐resolved MR fingerprinting for T 2 * signal extraction: MR fingerprinting meets echo planar time‐resolved imaging

    by Di Cui, Xiaoxi Liu, Peder E. Z. Larson, Duan Xu

    Purpose: This study leverages the echo planar time‐resolved imaging (EPTI) concept in MR fingerprinting (MRF) framework for a new time‐resolved MRF (TRMRF) approach, and explores its capability for fast simultaneous quantification of multiple MR parameters including T 1 , T 2 , T 2 *, proton density, off resonance, and B 1 + . Methods: The proposed TRMRF method uses the concept of EPTI to track the signal change along the EPI echo train for T 2 * weighting with a k‐t Poisson‐based sampling order designed for acquisition. A two‐dimensional decomposition algorithm was designed for the image reconstruction, enabling fast and precise subspace modeling. The accuracy of proposed method was evaluated by a T 1 /T 2 phantom. The feasibility was demonstrated through 5 healthy volunteer brain studies. Results: In the phantom studies, T 1 , T 2 , and T 2 * maps of TRMRF correlated strongly with gold‐standard methods. The concordance correlation coefficients are 0.9999, 0.9984 and 0.9978, and R 2 s are 0.9998, 0.9971, and 0.9983. In the in vivo studies, quantitative maps were acquired with 5 healthy volunteers. TRMRF was demonstrated to have comparable results with spiral MRF and gradient‐echo EPTI. TRMRF scans using 16, 10, and 6 s per slice were also evaluated to demonstrate the capability of shorter scan times. Conclusion: A new approach is proposed to exploit the advantage of EPTI in the MRF framework. We demonstrate in phantom and in vivo experiments that T 1 , T 2 , T 2 *, proton density, off resonance, and B 1 + can be simultaneously quantified within 6 s/slice by TRMRF.

  • Initial Experience of Metabolic Imaging With Hyperpolarized [1‐13C]pyruvate MRI in Kidney Transplant Patients

    by Xiaoxi Liu, Ying‐Chieh Lai, Di Cui, Shiang‐Cheng Kung, Meyeon Park, Zoltan Laszik, Peder E. Z. Larson, Zhen J. Wang

    Background: Kidney transplant is the treatment of choice for patients with end‐stage renal disease. Early detection of allograft injury is important to delay or prevent irreversible damage.Purpose: To investigate the feasibility of hyperpolarized (HP) [1‐13C]pyruvate MRI for assessing kidney allograft metabolism.Study Type: Prospective.Subjects: Six participants (mean age, 45.2 ± 12.4 years, two females) scheduled for kidney allograft biopsy and five patients (mean age, 59.6 ± 10.4 years, two females) with renal cell carcinoma (RCC).Field Strength/Sequence: Three Tesla, T2‐weighted fast spin echo, multi‐echo gradient echo, single shot diffusion‐weighted echo‐planar imaging, and time‐resolved HP 13C metabolite‐selective imaging.Assessment: Five of the six kidney allograft participants underwent biopsy after MRI. Estimated glomerular filtration rate (eGFR) and urine protein‐to‐creatine ratio (uPCR) were collected within 4 weeks of MRI. Kidney metabolism was quantified from HP [1‐13C]pyruvate MRI using the lactate‐to‐pyruvate ratio in allograft kidneys and non‐tumor bearing kidneys from RCC patients.Statistical Tests: Descriptive statistics (mean ± SD).Results: Biopsy was performed a mean of 9 days (range 5–19 days) after HP [1‐13C]pyruvate MRI. Three biopsies were normal, one showed low‐grade fibrosis and one showed moderate microvascular inflammation. All had stable functioning allografts with eGFR >60 mL/min/1.73 m2 and normal uPCR. One participant who did not undergo biopsy had reduced eGFR of 49 mL/min/1.73 m2 and elevated uPCR. The mean lactate‐to‐pyruvate ratio was 0.373 in participants with normal findings (N = 3) and 0.552 in participants with abnormal findings (N = 2). The lactate‐to‐pyruvate ratio was highest (0.847) in the participant with reduced eGFR and elevated uPRC. Native non‐tumor bearing kidneys had a mean lactate‐to‐pyruvate ratio of 0.309.Data Conclusion: Stable allografts with normal findings at biopsy showed lactate‐to‐pyruvate ratios similar to native non‐tumor bearing kidneys, whereas allografts with abnormal findings showed higher lactate‐to‐pyruvate ratios.Evidence Level: 2Technical Efficacy: Stage 2


  • A pharmacokinetic model for hyperpolarized 13C‐pyruvate MRI when using metabolite‐specific bSSFP sequences

    by Sule Sahin, Marie Frederikke Garnæs, Anna Bennett, Nicholas Dwork, Shuyu Tang, Xiaoxi Liu, Manushka Vaidya, Zhen Jane Wang, Peder E. Z. Larson

    Purpose Metabolite-specific balanced SSFP (MS-bSSFP) sequences are increasingly used in hyperpolarized [1-C-13]Pyruvate (HP C-13) MRI studies as they improve SNR by refocusing the magnetization each TR. Currently, pharmacokinetic models used to fit conversion rate constants, k(PL) and k(PB), and rate constant maps do not account for differences in the signal evolution of MS-bSSFP acquisitions. Methods In this work, a flexible MS-bSSFP model was built that can be used to fit conversion rate constants for these experiments. The model was validated in vivo using paired animal (healthy rat kidneys n = 8, transgenic adenocarcinoma of the mouse prostate n = 3) and human renal cell carcinoma (n = 3) datasets. Gradient echo (GRE) acquisitions were used with a previous GRE model to compare to the results of the proposed GRE-bSSFP model. Results In this work, a flexible MS-bSSFP model was built that can be used to fit conversion rate constants for these experiments. The model was validated in vivo using paired animal (healthy rat kidneys n = 8, transgenic adenocarcinoma of the mouse prostate n = 3) and human renal cell carcinoma (n = 3) datasets. Gradient echo (GRE) acquisitions were used with a previous GRE model to compare to the results of the proposed GRE-bSSFP model. Conclusion In this work, a flexible MS-bSSFP model was built that can be used to fit conversion rate constants for these experiments. The model was validated in vivo using paired animal (healthy rat kidneys n = 8, transgenic adenocarcinoma of the mouse prostate n = 3) and human renal cell carcinoma (n = 3) datasets. Gradient echo (GRE) acquisitions were used with a previous GRE model to compare to the results of the proposed GRE-bSSFP model.


  • 3D balanced SSFP UTE MRI for multiple contrasts whole brain imaging

    by Xin Shen, Eduardo Caverzasi, Yang Yang, Xiaoxi Liu, Ari Green, Roland G. Henry, Uzay Emir, Peder E. Z. Larson

    Purpose: This study aimed to develop a new high‐resolution MRI sequence for the imaging of the ultra‐short transverse relaxation time (uT2) components in the brain, while simultaneously providing proton density (PD) contrast for reference and quantification.Theory: The sequence combines low flip angle balanced SSFP (bSSFP) and UTE techniques, together with a 3D dual‐echo rosette k‐space trajectory for readout.Methods: The expected image contrast was evaluated by simulations. A study cohort of six healthy volunteers and eight multiple sclerosis (MS) patients was recruited to test the proposed sequence. Subtraction between two TEs was performed to extract uT2 signals. In addition, conventional longitudinal relaxation time (T1) weighted, T2‐weighted, and PD‐weighted MRI sequences were also acquired for comparison.Results: Typical PD‐contrast was found in the second TE images, while uT2 signals were selectively captured in the first TE images. The subtraction images presented signals primarily originating from uT2 components, but only if the first TE is short enough. Lesions in the MS subjects showed hyperintense signals in the second TE images but were hypointense signals in the subtraction images. The lesions had significantly lower signal intensity in subtraction images than normal white matter (WM), which indicated a reduction of uT2 components likely associated with myelin.Conclusion: 3D isotropic sub‐millimeter (0.94 mm) spatial resolution images were acquired with the novel bSSFP UTE sequence within 3 min. It provided easy extraction of uT2 signals and PD‐contrast for reference within a single acquisition.


  • Dynamic T2* relaxometry of hyperpolarized [1‐13C]pyruvate MRI in the human brain and kidneys

    by Xiaoxi Liu, Di Cui, Duan Xu, Robert Bok, Zhen J. Wang, Daniel B. Vigneron, Peder E. Z. Larson, Jeremy W. Gordon

    Purpose: This study aimed to quantify for hyperpolarized [1‐13C]pyruvate and metabolites in the healthy human brain and renal cell carcinoma (RCC) patients at 3 T.Methods: Dynamic values were measured with a metabolite‐specific multi‐echo spiral sequence. The dynamic of [1‐13C]pyruvate, [1‐13C]lactate, and 13C‐bicarbonate was estimated in regions of interest in the whole brain, sinus vein, gray matter, and white matter in healthy volunteers, as well as in kidney tumors and the contralateral healthy kidneys in a separate group of RCC patients. was fit using a mono‐exponential function; and metabolism was quantified using pyruvate‐to‐lactate conversion rate maps and lactate‐to‐pyruvate ratio maps, which were compared with and without an estimated correction.Results: The of pyruvate was shown to vary during the acquisition, whereas the of lactate and bicarbonate were relatively constant through time and across the organs studied. The of lactate was similar in gray matter (29.75 ± 1.04 ms), white matter (32.89 ± 0.9 ms), healthy kidney (34.61 ± 4.07 ms), and kidney tumor (33.01 ± 2.31 ms); and the of bicarbonate was different between whole‐brain (108.17 ± 14.05 ms) and healthy kidney (58.45 ± 6.63 ms). The of pyruvate had similar trends in both brain and RCC studies, reducing from 75.56 ± 2.23 ms to 22.24 ± 1.24 ms in the brain and reducing from 122.72 ± 9.86 ms to 57.38 ± 7.65 ms in the kidneys.Conclusion: Multi‐echo dynamic imaging can quantify and metabolism in a single integrated acquisition. Clear differences were observed in the of metabolites and in their behavior throughout the timecourse.


  • A metabolite specific 3D stack-of-spirals bSSFP sequence for improved bicarbonate imaging in hyperpolarized [1-13C]Pyruvate MRI

    by Xiaoxi Liu, Shuyu Tang, Di Cui, Robert A. Bok, Hsin-Yu Chen, Jeremy W. Gordon, Zhen J. Wang, Peder E.Z. Larson


  • Development of specialized magnetic resonance acquisition techniques for human hyperpolarized [13C,15N2]urea + [1‐13C]pyruvate simultaneous perfusion and metabolic imaging

    by Xiaoxi Liu, Shuyu Tang, Changhua Mu, Hecong Qin, Di Cui, Ying‐Chieh Lai, Andrew M. Riselli, Romelyn Delos Santos, Lucas Carvajal, Daniel Gebrezgiabhier, et al.

    Purpose: This study aimed to develop and demonstrate the in vivo feasibility of a 3D stack‐of‐spiral balanced steady‐state free precession(3D‐bSSFP) urea sequence, interleaved with a metabolite‐specific gradient echo (GRE) sequence for pyruvate and metabolic products, for improving the SNR and spatial resolution of the first hyperpolarized 13C‐MRI human study with injection of co‐hyperpolarized [1‐13C]pyruvate and [13C,15N2]urea.Methods: A metabolite‐specific bSSFP urea imaging sequence was designed using a urea‐specific excitation pulse, optimized TR, and 3D stack‐of‐spiral readouts. Simulations and phantom studies were performed to validate the spectral response of the sequence. The image quality of urea data acquired by the 3D‐bSSFP sequence and the 2D‐GRE sequence was evaluated with 2 identical injections of co‐hyperpolarized [1‐13C]pyruvate and [13C,15N2]urea formula in a rat. Subsequently, the feasibility of the acquisition strategy was validated in a prostate cancer patient.Results: Simulations and phantom studies demonstrated that 3D‐bSSFP sequence achieved urea‐only excitation, while minimally perturbing other metabolites (13C,15N2]urea. The human study demonstrated the in vivo feasibility and data quality of the acquisition strategy.Conclusion: The 3D‐bSSFP urea sequence with a stack‐of‐spiral acquisition demonstrated significantly increased SNR and image quality for [13C,15N2]urea in co‐hyperpolarized [1‐13C]pyruvate and [13C,15N2]urea imaging studies. This work lays the foundation for future human studies to achieve high‐quality and high‐SNR metabolism and perfusion images.