Raquel Carracedo Montero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raquel Carracedo Montero has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- María Cea
Clinical Microbiology Lab, Hospital Clínico Universitario de Santiago de Compostela (CHUS), 15706 Santiago de Compostela, Spain
2 shared publications - Adolfo de Salazar
Servicio de Microbiología, Hospital Universitario San Cecilio, Granada, Spain
1 shared publication - Alberto De La Iglesia1 shared publication
- Ana Fuentes
Servicio de Microbiología, Hospital Universitario Clínico San Cecilio, 18016 Granada, Spain
1 shared publication - Antonio Aguilera
Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, Spain
1 shared publication - Aurora García-Barrionuevo1 shared publication
Latest Publications
- Open Access
- 1 February 2024
- Published by MDPI AG in Preprints.org
Assessment of Performance and Comparison of Three Commercial HDV RNA Detection Assays: Implications for Diagnosis and Treatment Monitoring
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.
- 1 February 2024
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Performance and Comparison of Three Commercial HDV RNA Detection Assays: Implications for Diagnosis and Treatment Monitoring
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.
- Open Access
- 15 May 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (5) , 663
Direct Urine Resistance Detection Using VITEK 2
Urinary tract infections (UTIs) are the most common infectious diseases in both communities and hospitals. With non-anatomical or functional abnormalities, UTIs are usually self-limiting, though women suffer more reinfections throughout their lives. Certainly, antibiotic treatment leads to a more rapid resolution of symptoms, but also it selects resistant uropathogens and adversely affects the gut and vaginal microbiota. As uropathogens are increasingly becoming resistant to currently available antibiotics, it could be time to explore alternative strategies for managing UTIs. Rapid identification and antimicrobial susceptibility testing (AST) allow fast and precise treatment. The objective of this study was to shorten the time of diagnosis of UTIs by combining pathogen screening through flow cytometry, microbial identification by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS), and the VITEK 2 system for the direct analysis of urine samples. First, we selected positive urine samples by flow cytometry using UF5000, establishing the cut-off for positive at 150 bacteria/mL. After confirming the identification using MALDI-TOF MS and filtering the urine samples for Escherichia coli, we directly tested the AST N388 card using VITEK 2. We tested a total of 211 E. coli from urine samples. Cefoxitin, ertapenem, imipenem, gentamicin, nalidixic acid, ciprofloxacin, fosfomycin, and nitrofurantoin had no major important errors (MIE), and ampicillin, cefuroxime, and tobramycin showed higher MIEs. Cefepime, imipenem, and tobramycin had no major errors (ME). Fosfomycin was the antibiotic with the most MEs. The antibiotic with the most minor errors (mE) was ceftazidime. The total categorical agreement (CA) was 97.4% with a 95% CI of (96.8–97.9)95%. The direct AST from the urine samples proposed here was shorter by one day, without significant loss of sensibility regarding the standard diagnosis. Therefore, we hypothesize that this method is more realistic and better suited to human antibiotic concentrations.
- 15 May 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (5) , 663
Open AccessDirect Urine Resistance Detection Using VITEK 2
Urinary tract infections (UTIs) are the most common infectious diseases in both communities and hospitals. With non-anatomical or functional abnormalities, UTIs are usually self-limiting, though women suffer more reinfections throughout their lives. Certainly, antibiotic treatment leads to a more rapid resolution of symptoms, but also it selects resistant uropathogens and adversely affects the gut and vaginal microbiota. As uropathogens are increasingly becoming resistant to currently available antibiotics, it could be time to explore alternative strategies for managing UTIs. Rapid identification and antimicrobial susceptibility testing (AST) allow fast and precise treatment. The objective of this study was to shorten the time of diagnosis of UTIs by combining pathogen screening through flow cytometry, microbial identification by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS), and the VITEK 2 system for the direct analysis of urine samples. First, we selected positive urine samples by flow cytometry using UF5000, establishing the cut-off for positive at 150 bacteria/mL. After confirming the identification using MALDI-TOF MS and filtering the urine samples for Escherichia coli, we directly tested the AST N388 card using VITEK 2. We tested a total of 211 E. coli from urine samples. Cefoxitin, ertapenem, imipenem, gentamicin, nalidixic acid, ciprofloxacin, fosfomycin, and nitrofurantoin had no major important errors (MIE), and ampicillin, cefuroxime, and tobramycin showed higher MIEs. Cefepime, imipenem, and tobramycin had no major errors (ME). Fosfomycin was the antibiotic with the most MEs. The antibiotic with the most minor errors (mE) was ceftazidime. The total categorical agreement (CA) was 97.4% with a 95% CI of (96.8–97.9)95%. The direct AST from the urine samples proposed here was shorter by one day, without significant loss of sensibility regarding the standard diagnosis. Therefore, we hypothesize that this method is more realistic and better suited to human antibiotic concentrations.