AMAndre Mühlenbrock

Andre Mühlenbrock

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andre Mühlenbrock has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Virtual Reality–Based Mirror Guidance for Indirect Vision Training in Minimally Invasive Endodontic Access Cavity Preparation Among Dental Students: Randomized Controlled Crossover Trial

    by Unthitar Suranin, Metasit Getrak, Siriwan Suebnukarn, Peter Haddawy, Myat Su Yin, Rene Weller, Panuroot Aguilar, Kamon Budsaba, Andre Mühlenbrock, Gabriel Zachmann

    Background: Minimally invasive endodontics requires precise visualization to preserve tooth structure, often relying on indirect vision with a dental mirror—a challenging skill for dental students. Although virtual reality (VR) simulators provide immersive environments for dental training, most existing systems primarily focus on procedural simulation and haptic feedback, with limited capabilities for real-time mirror positioning and indirect visual guidance. Objective: The aim of this study was to evaluate verbal, visual, and haptic VR-based mirror guidance for indirect vision during minimally invasive endodontic access cavity preparation. Methods: Eligible fourth-year preclinical dental students were recruited through institutional email invitations and public announcements. A randomized controlled crossover trial was conducted with 30 participants, who completed all VR sessions in a simulation laboratory under direct investigator supervision to ensure standardized implementation of the training protocol. Participants performed simulated maxillary first molar access cavity preparations under 4 VR mirror guidance conditions—verbal guidance, visual guidance, haptic guidance, and no guidance—following a randomized 4 × 4 Latin square sequence with a 48-hour washout period between sessions. The primary outcome was outcome error score. Exploratory secondary outcomes included operating area visibility, operating area obstruction, operator posture error, task completion time, and Virtual Reality System Usability Questionnaire score. Outcomes were analyzed using linear mixed-effects models accounting for the crossover design. Estimated marginal mean differences (MDs) with 95% CIs and partial eta-squared (ηp2) effect sizes were reported, with Bonferroni-adjusted pairwise comparisons used to account for multiple comparisons. Results: Guidance modality significantly affected the primary outcome, outcome error score (F3,84=20.34; P<.001; ηp2=0.421). Compared with no guidance, outcome error scores were significantly lower with verbal (MD −0.50, 95% CI −0.76 to −0.24), visual (MD −0.68, 95% CI −0.94 to −0.42), and haptic guidance (MD −0.63, 95% CI −0.89 to −0.37; all adjusted P<.001). Guidance modality also significantly affected operating area visibility (F3,84=12.31; P<.001; ηp2=0.305). Compared with no guidance, visibility duration was significantly greater with verbal (MD 37.79, 95% CI 11.15-64.43 seconds; adjusted P=.001), visual (MD 59.15, 95% CI 32.51-85.79 seconds; adjusted P<.001), and haptic guidance (MD 31.52, 95% CI 4.90-58.15 seconds; adjusted P=.01). No significant differences were detected for operating area obstruction, operator posture error, task completion time, or usability. Conclusions: VR-based mirror guidance improved the outcome error score and increased operating area visibility during minimally invasive endodontic access cavity preparation. Verbal, visual, and haptic guidance resulted in fewer outcome errors and greater operating area visibility than no guidance, while no significant differences were detected in other performance measures or usability. These findings demonstrate the potential of diverse feedback modalities to provide effective guidance for indirect vision and inform future development of adaptive VR training systems using 1 or more modalities to suit learner needs. Trial Registration: Thai Clinical Trials Registry TCTR20260126008; https://www.thaiclinicaltrials.org/show/TCTR20260126008

  • Open Access

    Virtual Reality–Based Mirror Guidance for Indirect Vision Training in Minimally Invasive Endodontic Access Cavity Preparation Among Dental Students: Randomized Controlled Crossover Trial (Preprint)

    by Unthitar Suranin, Metasit Getrak, Siriwan Suebnukarn, Peter Haddawy, Myat Su Yin, Rene Weller, Panuroot Aguilar, Kamon Budsaba, Andre Mühlenbrock, Gabriel Zachmann

    BACKGROUND Minimally invasive endodontics requires precise visualization to preserve tooth structure, often relying on indirect vision with a dental mirror—a challenging skill for dental students. Although virtual reality (VR) simulators provide immersive environments for dental training, most existing systems primarily focus on procedural simulation and haptic feedback, with limited capabilities for real-time mirror positioning and indirect visual guidance. OBJECTIVE The aim of this study was to evaluate verbal, visual, and haptic VR-based mirror guidance for indirect vision during minimally invasive endodontic access cavity preparation. METHODS Eligible fourth-year preclinical dental students were recruited through institutional email invitations and public announcements. A randomized controlled crossover trial was conducted with 30 participants, who completed all VR sessions in a simulation laboratory under direct investigator supervision to ensure standardized implementation of the training protocol. Participants performed simulated maxillary first molar access cavity preparations under 4 VR mirror guidance conditions—verbal guidance, visual guidance, haptic guidance, and no guidance—following a randomized 4 × 4 Latin square sequence with a 48-hour washout period between sessions. The primary outcome was outcome error score. Exploratory secondary outcomes included operating area visibility, operating area obstruction, operator posture error, task completion time, and Virtual Reality System Usability Questionnaire score. Outcomes were analyzed using linear mixed-effects models accounting for the crossover design. Estimated marginal mean differences (MDs) with 95% CIs and partial eta-squared (ηp2) effect sizes were reported, with Bonferroni-adjusted pairwise comparisons used to account for multiple comparisons. RESULTS Guidance modality significantly affected the primary outcome, outcome error score (F3,84=20.34; P<.001; ηp2=0.421). Compared with no guidance, outcome error scores were significantly lower with verbal (MD −0.50, 95% CI −0.76 to −0.24), visual (MD −0.68, 95% CI −0.94 to −0.42), and haptic guidance (MD −0.63, 95% CI −0.89 to −0.37; all adjusted P<.001). Guidance modality also significantly affected operating area visibility (F3,84=12.31; P<.001; ηp2=0.305). Compared with no guidance, visibility duration was significantly greater with verbal (MD 37.79, 95% CI 11.15-64.43 seconds; adjusted P=.001), visual (MD 59.15, 95% CI 32.51-85.79 seconds; adjusted P<.001), and haptic guidance (MD 31.52, 95% CI 4.90-58.15 seconds; adjusted P=.01). No significant differences were detected for operating area obstruction, operator posture error, task completion time, or usability. CONCLUSIONS VR-based mirror guidance improved the outcome error score and increased operating area visibility during minimally invasive endodontic access cavity preparation. Verbal, visual, and haptic guidance resulted in fewer outcome errors and greater operating area visibility than no guidance, while no significant differences were detected in other performance measures or usability. These findings demonstrate the potential of diverse feedback modalities to provide effective guidance for indirect vision and inform future development of adaptive VR training systems using 1 or more modalities to suit learner needs. CLINICALTRIAL Thai Clinical Trials Registry TCTR20260126008; https://www.thaiclinicaltrials.org/show/TCTR20260126008

  • Open Access

    Using Gesture and Speech to Control Surgical Lighting Systems: Mixed Methods Study

    by Nima Zargham, Anke V Reinschluessel, Andre Mühlenbrock, Thomas Muender, Timur Cetin, Verena Nicole Uslar, Dirk Weyhe, Rainer Malaka, Tanja Döring

    Background: Surgical lighting systems (SLSs) provide optimal lighting conditions for operating room personnel. Current systems are mainly adjusted by hand; surgeons either accommodate the light themselves or communicate their requirements to an assistant to ensure optimal surgical conditions. This poses challenges to maintaining sterility, proper accessibility, and illumination and can lead to potential collision problems. Furthermore, the personnel operating the light may not have deep medical knowledge or equipment expertise. Objective: This paper introduces a touch-free interaction concept for controlling an SLS using speech and gestures. Methods: We used an iterative, user-centered design approach with participatory design sessions. This process involved conducting a literature review, several observations of actual surgical sites, and engaging stakeholders through interviews and focus groups. In addition, we carried out 2 user studies: one in a virtual reality setup and another in a living laboratory environment. Results: Our findings indicate that our interaction concept is a viable alternative for controlling an SLS. Despite some technical limitations, surgical experts found the system intuitive and useful, recognizing the significant potential for touch-free lighting adjustments in the operating room. The combination of speech and gesture modalities was seen as helpful and even necessary, with some interactions better suited to one modality over the other. Offering both modalities for each interaction provided greater flexibility. Conclusions: Our findings suggest that our proposed touch-free interaction concept can enhance surgical conditions and has the potential to replace traditional adjustment.


  • Open Access

    A Novel, Autonomous, Module-Based Surgical Lighting System

    by Andre Mühlenbrock, Hendrik Huscher, Verena Nicole Uslar, Timur Cetin, Rene Weller, Dirk Weyhe, Gabriel Zachmann

    Optimal illumination of the surgical site is crucial for successful surgeries. Current lighting systems, however, suffer from significant drawbacks, particularly shadows cast by surgeons and operating room personnel. We introduce an innovative, module-based lighting system that actively prevents shadows using an array of swiveling, ceiling-mounted light modules. The intensity and orientation of these modules are autonomously controlled by novel algorithms utilizing multiple depth sensors mounted above the operating table. This article presents our complete system, detailing the algorithms for autonomous control and the initial optimization of the light module setup. Unlike prior work that was largely conceptual and based on simulations, this study introduces a real prototype featuring 56 light modules and three depth sensors. We evaluate this prototype through measurements, semi-structured interviews ( n \(=\) 4), and an extensive quantitative user study ( n \(=\) 11). The evaluation focuses on illumination quality, shadow elimination, and suitability for open surgeries compared to conventional OR lights. Our results demonstrate that the novel lighting system and optimization algorithms outperform conventional OR lights for abdominal surgeries, according to both objective measures and subjective ratings by surgeons.


  • Open Access

    Using Gesture and Speech to Control Surgical Lighting Systems: Mixed Methods Study (Preprint)

    by Nima Zargham, Anke V Reinschluessel, Andre Mühlenbrock, Thomas Muender, Timur Cetin, Verena Nicole Uslar, Dirk Weyhe, Rainer Malaka, Tanja Döring

    BACKGROUND Surgical lighting systems (SLSs) provide optimal lighting conditions for operating room personnel. Current systems are mainly adjusted by hand; surgeons either accommodate the light themselves or communicate their requirements to an assistant to ensure optimal surgical conditions. This poses challenges to maintaining sterility, proper accessibility, and illumination and can lead to potential collision problems. Furthermore, the personnel operating the light may not have deep medical knowledge or equipment expertise. OBJECTIVE This paper introduces a touch-free interaction concept for controlling an SLS using speech and gestures. METHODS We used an iterative, user-centered design approach with participatory design sessions. This process involved conducting a literature review, several observations of actual surgical sites, and engaging stakeholders through interviews and focus groups. In addition, we carried out 2 user studies: one in a virtual reality setup and another in a living laboratory environment. RESULTS Our findings indicate that our interaction concept is a viable alternative for controlling an SLS. Despite some technical limitations, surgical experts found the system intuitive and useful, recognizing the significant potential for touch-free lighting adjustments in the operating room. The combination of speech and gesture modalities was seen as helpful and even necessary, with some interactions better suited to one modality over the other. Offering both modalities for each interaction provided greater flexibility. CONCLUSIONS Our findings suggest that our proposed touch-free interaction concept can enhance surgical conditions and has the potential to replace traditional adjustment.


  • Open Access

    Fast, accurate and robust registration of multiple depth sensors without need for RGB and IR images

    by Andre Mühlenbrock, Roland Fischer, Christoph Schröder-Dering, René Weller, Gabriel Zachmann

    Registration is an essential prerequisite for many applications when a multiple-camera setup is used. Due to the noise in depth images, registration procedures for depth sensors frequently rely on the detection of a target object in color or infrared images. However, this prohibits use cases where color and infrared images are not available or where there is no mapping between the pixels of different image types, e.g., due to separate sensors or different projections. We present our novel registration method that requires only the point cloud resulting from the depth image of each camera. For feature detection, we propose a combination of a custom-designed 3D registration target and an algorithm that is able to reliably detect that target and its features in noisy point clouds. Our evaluation indicates that our lattice detection is very robust (with a precision of more than 0.99) and very fast (on average about 20 ms with a single core). We have also compared our registration method with known methods: Our registration method achieves an accuracy of 1.6 mm at a distance of 2 m using only the noisy depth image, while the most accurate registration method achieves an accuracy of 0.7 mm requiring both the infrared and depth image.