TCTimur Cetin

Timur Cetin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Timur Cetin has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Using Gesture and Speech to Control Surgical Lighting Systems: Mixed Methods Study

    by Nima Zargham, Anke V Reinschluessel, Andre Mühlenbrock, Thomas Muender, Timur Cetin, Verena Nicole Uslar, Dirk Weyhe, Rainer Malaka, Tanja Döring

    Background: Surgical lighting systems (SLSs) provide optimal lighting conditions for operating room personnel. Current systems are mainly adjusted by hand; surgeons either accommodate the light themselves or communicate their requirements to an assistant to ensure optimal surgical conditions. This poses challenges to maintaining sterility, proper accessibility, and illumination and can lead to potential collision problems. Furthermore, the personnel operating the light may not have deep medical knowledge or equipment expertise. Objective: This paper introduces a touch-free interaction concept for controlling an SLS using speech and gestures. Methods: We used an iterative, user-centered design approach with participatory design sessions. This process involved conducting a literature review, several observations of actual surgical sites, and engaging stakeholders through interviews and focus groups. In addition, we carried out 2 user studies: one in a virtual reality setup and another in a living laboratory environment. Results: Our findings indicate that our interaction concept is a viable alternative for controlling an SLS. Despite some technical limitations, surgical experts found the system intuitive and useful, recognizing the significant potential for touch-free lighting adjustments in the operating room. The combination of speech and gesture modalities was seen as helpful and even necessary, with some interactions better suited to one modality over the other. Offering both modalities for each interaction provided greater flexibility. Conclusions: Our findings suggest that our proposed touch-free interaction concept can enhance surgical conditions and has the potential to replace traditional adjustment.


  • Open Access

    Measuring Bound Attention During Complex Liver Surgery Planning: Feasibility Study

    by Tim Schneider, Timur Cetin, Stefan Uppenkamp, Dirk Weyhe, Thomas Muender, Anke V Reinschluessel, Daniela Salzmann, Verena Uslar

    Background: The integration of advanced technologies such as augmented reality (AR) and virtual reality (VR) into surgical procedures has garnered significant attention. However, the introduction of these innovations requires thorough evaluation in the context of human-machine interaction. Despite their potential benefits, new technologies can complicate surgical tasks and increase the cognitive load on surgeons, potentially offsetting their intended advantages. It is crucial to evaluate these technologies not only for their functional improvements but also for their impact on the surgeon’s workload in clinical settings. A surgical team today must increasingly navigate advanced technologies such as AR and VR, aiming to reduce surgical trauma and enhance patient safety. However, each innovation needs to be evaluated in terms of human-machine interaction. Even if an innovation appears to bring advancements to the field it is applied in, it may complicate the work and increase the surgeon’s workload rather than benefiting the surgeon. Objective: This study aims to establish a method for objectively determining the additional workload generated using AR or VR glasses in a clinical context for the first time. Methods: Electroencephalography (EEG) signals were recorded using a passive auditory oddball paradigm while 9 participants performed surgical planning for liver resection across 3 different conditions: (1) using AR glasses, (2) VR glasses, and (3) the conventional planning software on a computer. Results: The electrophysiological results, that is, the potentials evoked by the auditory stimulus, were compared with the subjectively perceived stress of the participants, as determined by the National Aeronautics and Space Administration-Task Load Index (NASA-TLX) questionnaire. The AR condition had the highest scores for mental demand (median 75, IQR 70-85), effort (median 55, IQR 30-65), and frustration (median 40, IQR 15-75) compared with the VR and PC conditions. The analysis of the EEG revealed a trend toward a lower amplitude of the N1 component as well as for the P3 component at the central electrodes in the AR condition, suggesting a higher workload for participants when using AR glasses. In addition, EEG components in the VR condition did not reveal any noticeable differences compared with the EEG components in the conventional planning condition. For the P1 component, the VR condition elicited significantly earlier latencies at the Fz electrode (mean 75.3 ms, SD 25.8 ms) compared with the PC condition (mean 99.4 ms, SD 28.6 ms). Conclusions: The results suggest a lower stress level when using VR glasses compared with AR glasses, likely due to the 3D visualization of the liver model. Additionally, the alignment between subjectively determined results and objectively determined results confirms the validity of the study design applied in this research.


  • Open Access

    A Novel, Autonomous, Module-Based Surgical Lighting System

    by Andre Mühlenbrock, Hendrik Huscher, Verena Nicole Uslar, Timur Cetin, Rene Weller, Dirk Weyhe, Gabriel Zachmann

    Optimal illumination of the surgical site is crucial for successful surgeries. Current lighting systems, however, suffer from significant drawbacks, particularly shadows cast by surgeons and operating room personnel. We introduce an innovative, module-based lighting system that actively prevents shadows using an array of swiveling, ceiling-mounted light modules. The intensity and orientation of these modules are autonomously controlled by novel algorithms utilizing multiple depth sensors mounted above the operating table. This article presents our complete system, detailing the algorithms for autonomous control and the initial optimization of the light module setup. Unlike prior work that was largely conceptual and based on simulations, this study introduces a real prototype featuring 56 light modules and three depth sensors. We evaluate this prototype through measurements, semi-structured interviews ( n \(=\) 4), and an extensive quantitative user study ( n \(=\) 11). The evaluation focuses on illumination quality, shadow elimination, and suitability for open surgeries compared to conventional OR lights. Our results demonstrate that the novel lighting system and optimization algorithms outperform conventional OR lights for abdominal surgeries, according to both objective measures and subjective ratings by surgeons.


  • Open Access

    Using Gesture and Speech to Control Surgical Lighting Systems: Mixed Methods Study (Preprint)

    by Nima Zargham, Anke V Reinschluessel, Andre Mühlenbrock, Thomas Muender, Timur Cetin, Verena Nicole Uslar, Dirk Weyhe, Rainer Malaka, Tanja Döring

    BACKGROUND Surgical lighting systems (SLSs) provide optimal lighting conditions for operating room personnel. Current systems are mainly adjusted by hand; surgeons either accommodate the light themselves or communicate their requirements to an assistant to ensure optimal surgical conditions. This poses challenges to maintaining sterility, proper accessibility, and illumination and can lead to potential collision problems. Furthermore, the personnel operating the light may not have deep medical knowledge or equipment expertise. OBJECTIVE This paper introduces a touch-free interaction concept for controlling an SLS using speech and gestures. METHODS We used an iterative, user-centered design approach with participatory design sessions. This process involved conducting a literature review, several observations of actual surgical sites, and engaging stakeholders through interviews and focus groups. In addition, we carried out 2 user studies: one in a virtual reality setup and another in a living laboratory environment. RESULTS Our findings indicate that our interaction concept is a viable alternative for controlling an SLS. Despite some technical limitations, surgical experts found the system intuitive and useful, recognizing the significant potential for touch-free lighting adjustments in the operating room. The combination of speech and gesture modalities was seen as helpful and even necessary, with some interactions better suited to one modality over the other. Offering both modalities for each interaction provided greater flexibility. CONCLUSIONS Our findings suggest that our proposed touch-free interaction concept can enhance surgical conditions and has the potential to replace traditional adjustment.


  • Open Access

    Measuring Bound Attention During Complex Liver Surgery Planning: Feasibility Study (Preprint)

    by Tim Schneider, Timur Cetin, Stefan Uppenkamp, Dirk Weyhe, Thomas Muender, Anke V Reinschluessel, Daniela Salzmann, Verena Uslar

    BACKGROUND The integration of advanced technologies such as augmented reality (AR) and virtual reality (VR) into surgical procedures has garnered significant attention. However, the introduction of these innovations requires thorough evaluation in the context of human-machine interaction. Despite their potential benefits, new technologies can complicate surgical tasks and increase the cognitive load on surgeons, potentially offsetting their intended advantages. It is crucial to evaluate these technologies not only for their functional improvements but also for their impact on the surgeon’s workload in clinical settings. A surgical team today must increasingly navigate advanced technologies such as AR and VR, aiming to reduce surgical trauma and enhance patient safety. However, each innovation needs to be evaluated in terms of human-machine interaction. Even if an innovation appears to bring advancements to the field it is applied in, it may complicate the work and increase the surgeon’s workload rather than benefiting the surgeon. OBJECTIVE This study aims to establish a method for objectively determining the additional workload generated using AR or VR glasses in a clinical context for the first time. METHODS Electroencephalography (EEG) signals were recorded using a passive auditory oddball paradigm while 9 participants performed surgical planning for liver resection across 3 different conditions: (1) using AR glasses, (2) VR glasses, and (3) the conventional planning software on a computer. RESULTS The electrophysiological results, that is, the potentials evoked by the auditory stimulus, were compared with the subjectively perceived stress of the participants, as determined by the National Aeronautics and Space Administration-Task Load Index (NASA-TLX) questionnaire. The AR condition had the highest scores for mental demand (median 75, IQR 70-85), effort (median 55, IQR 30-65), and frustration (median 40, IQR 15-75) compared with the VR and PC conditions. The analysis of the EEG revealed a trend toward a lower amplitude of the N1 component as well as for the P3 component at the central electrodes in the AR condition, suggesting a higher workload for participants when using AR glasses. In addition, EEG components in the VR condition did not reveal any noticeable differences compared with the EEG components in the conventional planning condition. For the P1 component, the VR condition elicited significantly earlier latencies at the Fz electrode (mean 75.3 ms, SD 25.8 ms) compared with the PC condition (mean 99.4 ms, SD 28.6 ms). CONCLUSIONS The results suggest a lower stress level when using VR glasses compared with AR glasses, likely due to the 3D visualization of the liver model. Additionally, the alignment between subjectively determined results and objectively determined results confirms the validity of the study design applied in this research.