Ahmad Lutfi Bin Yusoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ahmad Lutfi Bin Yusoff has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Wan Fatihah Binti Wan Sohaimi
Department of Nuclear Medicine Radiotherapy & Oncology School of Medical Sciences Universiti Sains Malaysia, Health Campus Kubang Kerian Kelantan Malaysia
4 shared publications Zhitao Dai
Department of Radiation Oncology National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital Chinese Academy of Medical Sciences and Peking Union Medical College Shenzhen Guangdong China
2 shared publicationsIqbal Tariq
Department of Physics, NED University of Engineering & Technology, Karachi 75270, Pakistan
1 shared publicationMariatti Jaafar
School of Materials and Mineral Resources Engineering, Univeristi Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
1 shared publicationQingqing Yuan
National Cancer Center/National Clinical Research Center for Cancer/ Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
1 shared publication- Siti Khatijah Abdul Razak
Universiti Sains Malaysia
1 shared publication
Latest Publications
- Open Access
- 19 January 2026
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (1) , 77-87
A novel method for generating a fused ventilation–perfusion map using CT‐derived ventilation and FDG‐PET for lung functional avoidance in radiotherapy: A feasibility study
Background: Pulmonary ventilation–perfusion function plays a crucial role in both radiotherapy planning and prognosis assessment in patients with lung cancer. However, there remains a lack of rapid and cost‐effective imaging modalities capable of accurately capturing this functional parameter. Purpose: This study aimed to develop a lung functional image that reflects ventilation–perfusion characteristics by integrating computed tomography (CT) and (positron emission tomography) PET imaging techniques, with the objective of enhancing lung dose evaluation in radiotherapy planning. Approach: A retrospective analysis was performed on twenty lung cancer patients using CT images acquired at two respiratory phases and FDG‐PET/CT images. The Elastic Distortion algorithm was applied for deformable image registration, with the end‐expiration phase CT serving as the baseline. Values derived from the determinant Jacobian matrices of ventilation CT (V‐CT) images and the gray‐value matrices of PET images were normalized to a range of 0 to 1. These normalized values were multiplied to generate a ventilation–perfusion matrix. Three types of lung functional images were produced from these matrices: ventilation‐imaging (V‐imaging), perfusion‐imaging (P‐imaging), and ventilation–perfusion‐ imaging (VP‐imaging). The Dice Similarity Coefficient (DSC) and Bland–Altman plots were used to assess the correlations and discrepancies among the imaging modalities. Results: The DSC values for the entire lung, regions with low 30% functionality, and regions with high 40% functionality were 0.39 ± 0.05, 0.50 ± 0.03, and 0.20 ± 0.05 for V–P; 0.58 ± 0.03, 0.73 ± 0.03, and 0.32 ± 0.02 for V–VP; and 0.68 ± 0.04, 0.78 ± 0.04, and 0.34 ± 0.04 for P–VP, respectively. Notably, significant concordance was observed between V–VP and P–VP images within the delineated functional lung regions.#x02013;Altman analysis supported the DSC results, revealing high correlation coefficients in the low 30% functional lung region: 0.628 for V–P, 0.857 for V–VP, and 0.779 for P–VP. In contrast, similarity within the high 40% functional regions was markedly lower. Conclusion: This study developed a novel method for generating a fused VP map by integrating CT‐derived ventilation and FDG‐PET data. The method demonstrated feasibility, and the resulting VP map provided a balanced representation of both ventilation and perfusion signals, particularly in regions with reduced lung function.
- 19 January 2026
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (1) , 77-87
Open AccessA novel method for generating a fused ventilation–perfusion map using CT‐derived ventilation and FDG‐PET for lung functional avoidance in radiotherapy: A feasibility study
Background: Pulmonary ventilation–perfusion function plays a crucial role in both radiotherapy planning and prognosis assessment in patients with lung cancer. However, there remains a lack of rapid and cost‐effective imaging modalities capable of accurately capturing this functional parameter. Purpose: This study aimed to develop a lung functional image that reflects ventilation–perfusion characteristics by integrating computed tomography (CT) and (positron emission tomography) PET imaging techniques, with the objective of enhancing lung dose evaluation in radiotherapy planning. Approach: A retrospective analysis was performed on twenty lung cancer patients using CT images acquired at two respiratory phases and FDG‐PET/CT images. The Elastic Distortion algorithm was applied for deformable image registration, with the end‐expiration phase CT serving as the baseline. Values derived from the determinant Jacobian matrices of ventilation CT (V‐CT) images and the gray‐value matrices of PET images were normalized to a range of 0 to 1. These normalized values were multiplied to generate a ventilation–perfusion matrix. Three types of lung functional images were produced from these matrices: ventilation‐imaging (V‐imaging), perfusion‐imaging (P‐imaging), and ventilation–perfusion‐ imaging (VP‐imaging). The Dice Similarity Coefficient (DSC) and Bland–Altman plots were used to assess the correlations and discrepancies among the imaging modalities. Results: The DSC values for the entire lung, regions with low 30% functionality, and regions with high 40% functionality were 0.39 ± 0.05, 0.50 ± 0.03, and 0.20 ± 0.05 for V–P; 0.58 ± 0.03, 0.73 ± 0.03, and 0.32 ± 0.02 for V–VP; and 0.68 ± 0.04, 0.78 ± 0.04, and 0.34 ± 0.04 for P–VP, respectively. Notably, significant concordance was observed between V–VP and P–VP images within the delineated functional lung regions.#x02013;Altman analysis supported the DSC results, revealing high correlation coefficients in the low 30% functional lung region: 0.628 for V–P, 0.857 for V–VP, and 0.779 for P–VP. In contrast, similarity within the high 40% functional regions was markedly lower. Conclusion: This study developed a novel method for generating a fused VP map by integrating CT‐derived ventilation and FDG‐PET data. The method demonstrated feasibility, and the resulting VP map provided a balanced representation of both ventilation and perfusion signals, particularly in regions with reduced lung function.
- Open Access
- 2 September 2024
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 14, 1414337
Advances in CT-based lung function imaging for thoracic radiotherapy
The objective of this review is to examine the potential benefits and challenges of CT-based lung function imaging in radiotherapy over recent decades. This includes reviewing background information, defining related concepts, classifying and reviewing existing studies, and proposing directions for further investigation. The lung function imaging techniques reviewed herein encompass CT-based methods, specifically utilizing phase-resolved four-dimensional CT (4D-CT) or end-inspiratory and end-expiratory CT scans, to delineate distinct functional regions within the lungs. These methods extract crucial functional parameters, including lung volume and ventilation distribution, pivotal for assessing and characterizing the functional capacity of the lungs. CT-based lung ventilation imaging offers numerous advantages, notably in the realm of thoracic radiotherapy. By utilizing routine CT scans, additional radiation exposure and financial burdens on patients can be avoided. This imaging technique also enables the identification of different functional areas of the lung, which is crucial for minimizing radiation exposure to healthy lung tissue and predicting and detecting lung injury during treatment. In conclusion, CT-based lung function imaging holds significant promise for improving the effectiveness and safety of thoracic radiotherapy. Nevertheless, challenges persist, necessitating further research to address limitations and optimize clinical utilization. Overall, this review highlights the importance of CT-based lung function imaging as a valuable tool in radiotherapy planning and lung injury monitoring.
- 2 September 2024
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 14, 1414337
Open AccessAdvances in CT-based lung function imaging for thoracic radiotherapy
The objective of this review is to examine the potential benefits and challenges of CT-based lung function imaging in radiotherapy over recent decades. This includes reviewing background information, defining related concepts, classifying and reviewing existing studies, and proposing directions for further investigation. The lung function imaging techniques reviewed herein encompass CT-based methods, specifically utilizing phase-resolved four-dimensional CT (4D-CT) or end-inspiratory and end-expiratory CT scans, to delineate distinct functional regions within the lungs. These methods extract crucial functional parameters, including lung volume and ventilation distribution, pivotal for assessing and characterizing the functional capacity of the lungs. CT-based lung ventilation imaging offers numerous advantages, notably in the realm of thoracic radiotherapy. By utilizing routine CT scans, additional radiation exposure and financial burdens on patients can be avoided. This imaging technique also enables the identification of different functional areas of the lung, which is crucial for minimizing radiation exposure to healthy lung tissue and predicting and detecting lung injury during treatment. In conclusion, CT-based lung function imaging holds significant promise for improving the effectiveness and safety of thoracic radiotherapy. Nevertheless, challenges persist, necessitating further research to address limitations and optimize clinical utilization. Overall, this review highlights the importance of CT-based lung function imaging as a valuable tool in radiotherapy planning and lung injury monitoring.
- Open Access
- 31 August 2023
- Published by Springer Nature in European Journal of Medical Research
- Vol. 28 (1) , 1-9
Study on the transferability of the knowledge-based VMAT model to predict IMRT plans in prostate cancer radiotherapy
The aim of this study was to investigate the feasibility of VMAT library-derived model transfer in the prediction of IMRT plans by dosimetry comparison among with three groups of IMRT plans: two groups of automatic IMRT plans generated by the knowledge-based the volumetric modulated arc therapy (VMAT) model and intensity-modulated radiation therapy (IMRT) model and one group of manual IMRT plans. 52 prostate cancer patients who had completed radiotherapy were selected and randomly divided into 2 groups with 40 and 12 separately. Then both VMAT and IMRT plans were manually designed for all patients. The total plans in the group with 40 cases as training datasets were added to the knowledge-based planning (KBP) models for learning and finally obtained VMAT and IMRT training models. Another 12 cases were selected as the validation group to be used to generated auto IMRT plans by KBP VMAT and IMRT models. At last, the radiotherapy plans from three groups were obtained: the automated IMRT plan (V-IMRT) predicted by the VMAT model, the automated IMRT plan (I-IMRT) predicted by the IMRT model and the manual IMRT plan (M-IMRT) designed before. The dosimetric parameters of planning target volume (PTV) and organ at risks (OARs) as well as the time parameters (monitor unit, MU) were statistically analyzed. The dose limit of all plans in the training datasets met the clinical requirements. Compared with the training plans added to VMAT model, the dosimetry parameters have no statistical differences in PTV (P > 0.05); the dose of X% volume (Dx%) with D25% and D35% in rectal and the maximum dose (Dmax) in the right femoral head were lower (P = 0.04, P = 0.01, P = 0.00) while D50% in rectal was higher (< 0.05) in the IMRT model plans. In the 12 validation cases, both automated plans showed better dose distribution compared with the M-IMRT plan: the Dmax of PTV in the I-IMRT plans and the dose in volume of interesting (VOI) of bladder and bilateral femoral heads were lower with a statistically significant difference (P < 0.05). Compared with the I-IMRT plans, dosimetric parameters in PTV and VOI of all OARs had no statistically significant differences (P > 0.05), but the Dmax in left femoral heard and D15% in the right femoral head were lower and have significant differences (P < 0.05). Furthermore, the low-dose regions, which was defined as all volumes outside of the PTV (RV) with the statistical parameters of mean dose (Dmean), the volume of covering more than 5 Gy dose (V5Gy), and also the time parameter (MU) required to perform the plan were considered. The results showed that Dmean in V-IMRT was smaller than that in the I-IMRT plan (P = 0.02) and there was no significant difference in V5Gy and MU (P > 0.05). Compared with the manual plan, the IMRT plans generated by the KBP models had a significant advantage in dose control of both OARs and PTV. Compared to the I-IMRT plans, the V-IMRT plans was not only without significant disadvantages, but it also achieved slightly better control of the low-dose region, which meet the clinical requirements and can used in the clinical treatment. This study demonstrates that it is feasible to transfer the KBP VMAT model in the prediction of IMRT plans.
- 31 August 2023
- Published by Springer Nature in European Journal of Medical Research
- Vol. 28 (1) , 1-9
Open AccessStudy on the transferability of the knowledge-based VMAT model to predict IMRT plans in prostate cancer radiotherapy
The aim of this study was to investigate the feasibility of VMAT library-derived model transfer in the prediction of IMRT plans by dosimetry comparison among with three groups of IMRT plans: two groups of automatic IMRT plans generated by the knowledge-based the volumetric modulated arc therapy (VMAT) model and intensity-modulated radiation therapy (IMRT) model and one group of manual IMRT plans. 52 prostate cancer patients who had completed radiotherapy were selected and randomly divided into 2 groups with 40 and 12 separately. Then both VMAT and IMRT plans were manually designed for all patients. The total plans in the group with 40 cases as training datasets were added to the knowledge-based planning (KBP) models for learning and finally obtained VMAT and IMRT training models. Another 12 cases were selected as the validation group to be used to generated auto IMRT plans by KBP VMAT and IMRT models. At last, the radiotherapy plans from three groups were obtained: the automated IMRT plan (V-IMRT) predicted by the VMAT model, the automated IMRT plan (I-IMRT) predicted by the IMRT model and the manual IMRT plan (M-IMRT) designed before. The dosimetric parameters of planning target volume (PTV) and organ at risks (OARs) as well as the time parameters (monitor unit, MU) were statistically analyzed. The dose limit of all plans in the training datasets met the clinical requirements. Compared with the training plans added to VMAT model, the dosimetry parameters have no statistical differences in PTV (P > 0.05); the dose of X% volume (Dx%) with D25% and D35% in rectal and the maximum dose (Dmax) in the right femoral head were lower (P = 0.04, P = 0.01, P = 0.00) while D50% in rectal was higher (< 0.05) in the IMRT model plans. In the 12 validation cases, both automated plans showed better dose distribution compared with the M-IMRT plan: the Dmax of PTV in the I-IMRT plans and the dose in volume of interesting (VOI) of bladder and bilateral femoral heads were lower with a statistically significant difference (P < 0.05). Compared with the I-IMRT plans, dosimetric parameters in PTV and VOI of all OARs had no statistically significant differences (P > 0.05), but the Dmax in left femoral heard and D15% in the right femoral head were lower and have significant differences (P < 0.05). Furthermore, the low-dose regions, which was defined as all volumes outside of the PTV (RV) with the statistical parameters of mean dose (Dmean), the volume of covering more than 5 Gy dose (V5Gy), and also the time parameter (MU) required to perform the plan were considered. The results showed that Dmean in V-IMRT was smaller than that in the I-IMRT plan (P = 0.02) and there was no significant difference in V5Gy and MU (P > 0.05). Compared with the manual plan, the IMRT plans generated by the KBP models had a significant advantage in dose control of both OARs and PTV. Compared to the I-IMRT plans, the V-IMRT plans was not only without significant disadvantages, but it also achieved slightly better control of the low-dose region, which meet the clinical requirements and can used in the clinical treatment. This study demonstrates that it is feasible to transfer the KBP VMAT model in the prediction of IMRT plans.
- 20 May 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 186, 110293
UV/Vis dose response of a reusable PMMA-NaCl polymer composite
- 20 May 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 186, 110293
UV/Vis dose response of a reusable PMMA-NaCl polymer composite