A novel method for generating a fused ventilation–perfusion map using CT‐derived ventilation and FDG‐PET for lung functional avoidance in radiotherapy: A feasibility study
Open Access
- 19 January 2026
- journal article
- Published by Wiley in Precision Radiation Oncology
- Vol. 10 (1) , 77-87
Abstract
Background: Pulmonary ventilation–perfusion function plays a crucial role in both radiotherapy planning and prognosis assessment in patients with lung cancer. However, there remains a lack of rapid and cost‐effective imaging modalities capable of accurately capturing this functional parameter. Purpose: This study aimed to develop a lung functional image that reflects ventilation–perfusion characteristics by integrating computed tomography (CT) and (positron emission tomography) PET imaging techniques, with the objective of enhancing lung dose evaluation in radiotherapy planning. Approach: A retrospective analysis was performed on twenty lung cancer patients using CT images acquired at two respiratory phases and FDG‐PET/CT images. The Elastic Distortion algorithm was applied for deformable image registration, with the end‐expiration phase CT serving as the baseline. Values derived from the determinant Jacobian matrices of ventilation CT (V‐CT) images and the gray‐value matrices of PET images were normalized to a range of 0 to 1. These normalized values were multiplied to generate a ventilation–perfusion matrix. Three types of lung functional images were produced from these matrices: ventilation‐imaging (V‐imaging), perfusion‐imaging (P‐imaging), and ventilation–perfusion‐ imaging (VP‐imaging). The Dice Similarity Coefficient (DSC) and Bland–Altman plots were used to assess the correlations and discrepancies among the imaging modalities. Results: The DSC values for the entire lung, regions with low 30% functionality, and regions with high 40% functionality were 0.39 ± 0.05, 0.50 ± 0.03, and 0.20 ± 0.05 for V–P; 0.58 ± 0.03, 0.73 ± 0.03, and 0.32 ± 0.02 for V–VP; and 0.68 ± 0.04, 0.78 ± 0.04, and 0.34 ± 0.04 for P–VP, respectively. Notably, significant concordance was observed between V–VP and P–VP images within the delineated functional lung regions.#x02013;Altman analysis supported the DSC results, revealing high correlation coefficients in the low 30% functional lung region: 0.628 for V–P, 0.857 for V–VP, and 0.779 for P–VP. In contrast, similarity within the high 40% functional regions was markedly lower. Conclusion: This study developed a novel method for generating a fused VP map by integrating CT‐derived ventilation and FDG‐PET data. The method demonstrated feasibility, and the resulting VP map provided a balanced representation of both ventilation and perfusion signals, particularly in regions with reduced lung function.Keywords
This publication has 35 references indexed in Scilit:
- Four‐dimensional computed tomography‐based ventilation imaging in intensity‐modulated radiation therapy treatment planning for pulmonary functional avoidanceJournal of Applied Clinical Medical Physics, 2023
- The emergence of PET/CT: Engineering, innovation, and usageMedical Physics, 2022
- Calibrating the Dice Loss to Handle Neural Network Overconfidence for Biomedical Image SegmentationJournal of Digital Imaging, 2022
- A deep learning method for translating 3DCT to SPECT ventilation imaging: First comparison with 81mKr‐gas SPECT ventilation imagingMedical Physics, 2022
- Technical Note: On the spatial correlation between robust CT‐ventilation methods and SPECT ventilationMedical Physics, 2020
- Technical Note: Deriving ventilation imaging from 4DCT by deep convolutional neural networkMedical Physics, 2019
- Evaluating the accuracy of 4D‐CT ventilation imaging: First comparison with Technegas SPECT ventilationMedical Physics, 2017
- Priority-driven plan optimization in locally advanced lung patients based on perfusion SPECT imagingAdvances in Radiation Oncology, 2016
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Functional ImagingClinics in Chest Medicine, 2015