PSPatrick Salvia

Patrick Salvia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Patrick Salvia has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The A-Palp: A Digitized Manual Palpation Method for Sagittal Spine Assessment—A Study of Reliability over Time and Between Operators

    by Guillaume Claus, Joe Abi Nader, Laurent Fabeck, Alphonse Lubansu, Patrick Salvia, Benoit Beyer, Véronique Feipel

    Background/Objectives: The A-Palp enables a calibrated anatomical systems technique (CAST) approach. Previous studies have demonstrated repeatability and concurrent validity for selected spinal curvature angles in patients with scoliosis. However, the inter-operator reproducibility, temporal repeatability, and reliability of sagittal spinal curvature measurements and spinopelvic parameters remain to be established. Methods: Eighteen healthy adults without spinal pathology were assessed. Two operators sampled sagittal spinal profiles with the A-Palp in a 14-camera optoelectronic setup, applying reflective markers and palpating spinous processes. One operator repeated measurements after seven days. Marker data were processed in MATLAB (R2019b) to smooth trajectories, fit curvature arcs, and compute extracorporeal kyphosis, lordosis, and pelvic parameters. Reliability and repeatability were evaluated using Bland & Altman analysis, intraclass correlations (ICCs), standard error of measurement (SEM), mean detectable change (MDC95), root-mean-squared errors (RMSEs), and Statistical Parametric Mapping (SPM). Results: Reliability and repeatability were strong. For global spinal angles, ICCs exceeded 0.90 across operators and sessions. The tangent method yielded low SEM (1–2°) and MDC95 (3–6°) values, whereas the circle-fit/trigonometric methods showed larger errors. Most spinopelvic angles had moderate-to-excellent ICCs (0.65–0.98) with SEM/MDC95 values ≈2.1–4.5°/5.9–12.4°. Ground reaction force-referenced distances showed good ICCs and small intra-operator error (SEM: 3.8–4.8 mm; MDC95: 10.7–13.4 mm) but wider inter-session thresholds (SEM: 10.3–11.6 mm; MDC95: 28.6–32.8 mm). Bland & Altman biases were ~0, with narrower limits for the tangent (≈±5°) than circle-fit/trigonometric (≈±8–12°) methods. Curve tracking was consistent (RMSE: 2.7–3.7 mm, <5% amplitude), and SPM detected no point-wise differences. Conclusions: The A-Palp method demonstrated high reliability and repeatability for extracorporeal sagittal spinal and sacro-spinal evaluation. Variability was low across operators and sessions, supporting its use as a robust, non-invasive clinical and research tool.


  • Digitization of three-dimensional spine curvature profile in adolescent idiopathic scoliosis using anatomical palpation

    by Patrick Salvia, Robert Elbaum, Emilie Bourgois, Shanon Péché, Véronique Feipel, Benoit Beyer

    The need for spaced radiological follow-up of adolescents with idiopathic scoliosis (AIS) stimulates the development of radiation-free methodologies to document spinal curvature parameters. The aim of the study was to develop a methodology, referred to as A-Palp, using index finger pulp palpation to assess 3D spinal curvature in the standing position in patients and control group. To estimate repeatability for 2D/3D curvature angles, three manual palpations of spinal curvature were performed by one examiner using an index finger pulp calibrated in an optoelectronic system to acquire these curvature angles in the sagittal and frontal planes and in the 3D plane of maximum curvature. The intrarater repeatability was analysed by generalisability theory and the dependability index ϕ combined with a decision D-study to judge the number of desirable repetitions. The A-Palp/radiograph concurrent validity of 2D/3D apex angles was studied by linear regression and Bland–Altman plot. For the scoliosis angle in AIS patients, the ϕ index was excellent, above 0.9, with a standard error of measurement and minimal detectable change below 3° and 9°, respectively. For A-Palp/radiograph comparison, 95% of 2D and 3D measurement results were between 8° and 11° below and 12° and 5° above the radiographic apex angle, respectively, with a bias below 3°. The good repeatability and concurrent validity show that this innovative radiation-free 3D methodology seems suitable for the assessment of AIS patients when the same examiner repeats the measurement two or three times according to the D-study.