Masayuki Mizuno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masayuki Mizuno has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Jong-Jin Jeong
Department of Architecture Engineering, Chosun University, Gwangju 61452, Korea
3 shared publications - Kye-Won Park
Senior Researcher, Fire Safety & Building Environment System Research Team, Fire Insurers Laboratories of Korea, Korea
3 shared publications M. Yamashina
NEC Corporation,Kanagawa,Japan
3 shared publications- Chang-Geun Cho
Department of Architectural Engineering, Chosun University, Gwangju, Republic of Korea
2 shared publications - SeongKyung Park
Tokyo University of Science
2 shared publications A. Shibayama
NEC Corp.
1 shared publication
Latest Publications
- Open Access
- 17 November 2026
- Published by Elsevier in Safety Science
- Vol. 207
Analysis of counterflow-induced congestion propagation in a high-rise office building staircase: evidence from a full-building phased evacuation drill
- 17 November 2026
- Published by Elsevier in Safety Science
- Vol. 207
Open AccessAnalysis of counterflow-induced congestion propagation in a high-rise office building staircase: evidence from a full-building phased evacuation drill
- 12 April 2026
- Published by Wiley in Fire and Materials
- Vol. 50 (4) , 430-438
Prediction of Flame‐Spread on Horizontal Combustibles
The flame spread behavior of horizontal combustibles such as pocket coil mattresses in residential houses was investigated under various installation height conditions, and an existing predictive model was refined. In a series of experiments, mattresses were tested with diverse installation heights (ranging from 0 to 515 mm) using the standard ignition source specified by ISO 12949:2011. The experimental results revealed that both the fire growth rate and the maximum heat release rate increased with higher mattress installation height. During combustion, molten material and mattress fragments descended and ignited on the floor. The flames associated with the combustion on the floor affected the combustion of the mattress body, leading to a correlation between higher mattress installation height and increased heat release rates and fire growth rates. Traditionally, flame spread speed is determined by the incident heat flux to the horizontal and upper surfaces of the solid combustible material adjacent to the flame. However, a modified model was proposed that accounts for the influence of both convective and radiant heat fluxes generated by the flames on the floor, impacting the cross‐section of the burning mattress body.
- 12 April 2026
- Published by Wiley in Fire and Materials
- Vol. 50 (4) , 430-438
Prediction of Flame‐Spread on Horizontal Combustibles
The flame spread behavior of horizontal combustibles such as pocket coil mattresses in residential houses was investigated under various installation height conditions, and an existing predictive model was refined. In a series of experiments, mattresses were tested with diverse installation heights (ranging from 0 to 515 mm) using the standard ignition source specified by ISO 12949:2011. The experimental results revealed that both the fire growth rate and the maximum heat release rate increased with higher mattress installation height. During combustion, molten material and mattress fragments descended and ignited on the floor. The flames associated with the combustion on the floor affected the combustion of the mattress body, leading to a correlation between higher mattress installation height and increased heat release rates and fire growth rates. Traditionally, flame spread speed is determined by the incident heat flux to the horizontal and upper surfaces of the solid combustible material adjacent to the flame. However, a modified model was proposed that accounts for the influence of both convective and radiant heat fluxes generated by the flames on the floor, impacting the cross‐section of the burning mattress body.
- Open Access
- 30 June 2025
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 39 (2) , 148-163
Suggestion of Optimal Phased Evacuation Scenario Developing and Evaluating Methods for High-Rise Buildings
This research proposes methods for developing and evaluating optimal phased evacuation scenarios for high-rise buildings using the SimTread evacuation simulation to analyze conditions causing congestion and those capable of responding to mass evacuation start time fluctuations. Phased evacuation is essential to prevent congestion when all occupants simultaneously move to staircases during fires, which can delay evacuation from priority floors. The study aims to develop evacuation plans that satisfy three key conditions: 1) prioritizing evacuation of floors with high fire or smoke spread risk, 2) preventing heavy congestion in staircases, and 3) maintaining continuous evacuation flow at the first-floor exit despite time intervals between phases. To achieve these objectives, methodology was developed based on evacuation drills conducted in a 25-story office building in Tokyo and simulation results. The research determined that simultaneous evacuation of no more than 400 people per phase prevents heavy congestion. Additionally, appropriate time intervals between phases were established to maintain evacuation flow continuity. To evaluate the proposed methodology's validity, three indicators were developed: 1) Flow Status Indicator at First Floor Exit (RF), 2) Staircase Indoor Congestion Indicator on Each Floor (RC), and 3) Evacuation Time Index for Allowable Time According to Combustion and Smoke Propagation Risk (RS). Through case studies with different fire floor scenarios (lower, middle, and upper floors), the research confirmed the proposed methodology effectively develops and evaluates efficient phased evacuation scenarios for high-rise buildings. The findings contribute to enhancing evacuation safety in high-rise buildings by providing systematic methods for creating phased evacuation scenarios that balance priority evacuation, congestion prevention, and overall evacuation efficiency.
- 30 June 2025
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 39 (2) , 148-163
Open AccessSuggestion of Optimal Phased Evacuation Scenario Developing and Evaluating Methods for High-Rise Buildings
This research proposes methods for developing and evaluating optimal phased evacuation scenarios for high-rise buildings using the SimTread evacuation simulation to analyze conditions causing congestion and those capable of responding to mass evacuation start time fluctuations. Phased evacuation is essential to prevent congestion when all occupants simultaneously move to staircases during fires, which can delay evacuation from priority floors. The study aims to develop evacuation plans that satisfy three key conditions: 1) prioritizing evacuation of floors with high fire or smoke spread risk, 2) preventing heavy congestion in staircases, and 3) maintaining continuous evacuation flow at the first-floor exit despite time intervals between phases. To achieve these objectives, methodology was developed based on evacuation drills conducted in a 25-story office building in Tokyo and simulation results. The research determined that simultaneous evacuation of no more than 400 people per phase prevents heavy congestion. Additionally, appropriate time intervals between phases were established to maintain evacuation flow continuity. To evaluate the proposed methodology's validity, three indicators were developed: 1) Flow Status Indicator at First Floor Exit (RF), 2) Staircase Indoor Congestion Indicator on Each Floor (RC), and 3) Evacuation Time Index for Allowable Time According to Combustion and Smoke Propagation Risk (RS). Through case studies with different fire floor scenarios (lower, middle, and upper floors), the research confirmed the proposed methodology effectively develops and evaluates efficient phased evacuation scenarios for high-rise buildings. The findings contribute to enhancing evacuation safety in high-rise buildings by providing systematic methods for creating phased evacuation scenarios that balance priority evacuation, congestion prevention, and overall evacuation efficiency.
- 20 June 2024
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 33 (9) , 1645-1664
Improving precision of evacuation simulation: A comparative analysis between evacuation drill and SimTread simulation results
In a fire, stairways are the primary avenues for building evacuation. Previous studies focused on investigating evacuation flow through evacuation drills in a high-rise office building to assess the accuracy of evacuation scenarios and compared them with evacuation dynamics. However, the effectiveness of evacuation drills in estimating many scenarios is limited by actual drills. The evacuation simulations present a promising approach to objectively evaluating evacuation scenarios. This study verifies whether evacuation simulations can faithfully replicate actual evacuation flow and effectively predict suitable evacuation scenarios or potentially involve parameter calibration. Through a comprehensive comparison analysis, this study scrutinized the reliability of evacuation simulations and calibrated the simulation parameters. The analysis revealed that factors, including adjustments to the door width, personal space considerations for occupants in both conflict and normal situations and variations in staircase structure configuration, can significantly influence the evacuation flow within staircases. Manipulating these parameters in simulations would enable a more precise replication of evacuation flow within staircases, thereby enhancing the simulation’s accuracy in target evacuation scenarios. The findings of this research have underscored the significance of employing advanced simulation techniques to model evacuation dynamics accurately, facilitating a robust framework for devising effective emergency evacuation strategies in high-rise office buildings.
- 20 June 2024
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 33 (9) , 1645-1664
Improving precision of evacuation simulation: A comparative analysis between evacuation drill and SimTread simulation results
In a fire, stairways are the primary avenues for building evacuation. Previous studies focused on investigating evacuation flow through evacuation drills in a high-rise office building to assess the accuracy of evacuation scenarios and compared them with evacuation dynamics. However, the effectiveness of evacuation drills in estimating many scenarios is limited by actual drills. The evacuation simulations present a promising approach to objectively evaluating evacuation scenarios. This study verifies whether evacuation simulations can faithfully replicate actual evacuation flow and effectively predict suitable evacuation scenarios or potentially involve parameter calibration. Through a comprehensive comparison analysis, this study scrutinized the reliability of evacuation simulations and calibrated the simulation parameters. The analysis revealed that factors, including adjustments to the door width, personal space considerations for occupants in both conflict and normal situations and variations in staircase structure configuration, can significantly influence the evacuation flow within staircases. Manipulating these parameters in simulations would enable a more precise replication of evacuation flow within staircases, thereby enhancing the simulation’s accuracy in target evacuation scenarios. The findings of this research have underscored the significance of employing advanced simulation techniques to model evacuation dynamics accurately, facilitating a robust framework for devising effective emergency evacuation strategies in high-rise office buildings.
- Open Access
- 2 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 11099
Estimation of Thermal Radiation in Bed Mattresses
The population density of cities has been increasing with time and the development of industry. Building fires in large cities with high population density cause extensive human and property damage. To prevent such damage, the characteristics of flames such as the thermal radiation and intensity of the fire source must be considered when designing building structures. However, the consideration of these factors is practically inadequate. Accordingly, in this study, when a mattress was ignited in an open environment at a different installation height (0–515 mm), the measurements from a heat flux meter and the calculated thermal radiation were compared, and a comparative analysis was conducted using the existing prediction formulas by researchers described in ISO 24678-7. We examined the fire risk of mattresses according to the mattress installation height. As a result, the fire risk of the mattress was confirmed according to the mattress installation height; upon comparing the experimental and calculated values for radiant heat, it was found to be necessary to estimate the radiant heat using a calculation method that applies the configuration factor differently depending on the change in the flame shape. In addition, as a result of substituting the experimental value into the calculation method of ISO 24678-7 (a method for estimating the radiant heat of liquid combustibles), the experimental value and the calculated value were found to be significantly different. Therefore, similar to ISO 24678-7 for the radiation heat estimation method for “liquid combustibles”, an international standard for establishing the radiation heat estimation method for “solid combustible materials” as a standard was also required for a reasonable analysis of the fire safety phenomenon of solid materials, such as bed mattresses.
- 2 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 11099
Open AccessEstimation of Thermal Radiation in Bed Mattresses
The population density of cities has been increasing with time and the development of industry. Building fires in large cities with high population density cause extensive human and property damage. To prevent such damage, the characteristics of flames such as the thermal radiation and intensity of the fire source must be considered when designing building structures. However, the consideration of these factors is practically inadequate. Accordingly, in this study, when a mattress was ignited in an open environment at a different installation height (0–515 mm), the measurements from a heat flux meter and the calculated thermal radiation were compared, and a comparative analysis was conducted using the existing prediction formulas by researchers described in ISO 24678-7. We examined the fire risk of mattresses according to the mattress installation height. As a result, the fire risk of the mattress was confirmed according to the mattress installation height; upon comparing the experimental and calculated values for radiant heat, it was found to be necessary to estimate the radiant heat using a calculation method that applies the configuration factor differently depending on the change in the flame shape. In addition, as a result of substituting the experimental value into the calculation method of ISO 24678-7 (a method for estimating the radiant heat of liquid combustibles), the experimental value and the calculated value were found to be significantly different. Therefore, similar to ISO 24678-7 for the radiation heat estimation method for “liquid combustibles”, an international standard for establishing the radiation heat estimation method for “solid combustible materials” as a standard was also required for a reasonable analysis of the fire safety phenomenon of solid materials, such as bed mattresses.
- Open Access
Fire Properties of Bed Mattresses Focusing on the Fire Growth Rate and Flame Height
Bed mattresses are rated as products to cause a fire hazard because of their very high heat release rate among indoor combustibles. In this study, fire growth rate and flame height were measured through a series of combustion experiments on a full scale in order to provide information regarding mattress fire characteristics. The experiments were conducted in an open space, and bed mattresses as the test samples were installed at different installation heights (0~515 mm). The experiment results revealed that the higher the bed mattress was installed, the higher the fire growth rate, the heat release rate, and the flame height. Additionally, the time of the mattress to reach 1 MW was evaluated as the category “medium” in the NFPA 72 standards. The flame heights showed a good coincidence compared to the existing flame height model equations, proving the applicability of the model to the mattress combustion.
Open AccessFire Properties of Bed Mattresses Focusing on the Fire Growth Rate and Flame Height
Bed mattresses are rated as products to cause a fire hazard because of their very high heat release rate among indoor combustibles. In this study, fire growth rate and flame height were measured through a series of combustion experiments on a full scale in order to provide information regarding mattress fire characteristics. The experiments were conducted in an open space, and bed mattresses as the test samples were installed at different installation heights (0~515 mm). The experiment results revealed that the higher the bed mattress was installed, the higher the fire growth rate, the heat release rate, and the flame height. Additionally, the time of the mattress to reach 1 MW was evaluated as the category “medium” in the NFPA 72 standards. The flame heights showed a good coincidence compared to the existing flame height model equations, proving the applicability of the model to the mattress combustion.
- 1 January 2008
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2008, _1A1-A19_1
1A1-A19 Motion Generations for Multi-joint Robots Based on Basis-Motion Composition
- 1 January 2008
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2008, _1A1-A19_1
1A1-A19 Motion Generations for Multi-joint Robots Based on Basis-Motion Composition
- 23 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 300-301,
Elastic-Vt CMOS circuits for multiple on-chip power control
- 23 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 300-301,
Elastic-Vt CMOS circuits for multiple on-chip power control
- 1 January 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 418-419
A 1 GIPS 1 W single-chip tightly-coupled four-way multiprocessor with architecture support for multiple control flow execution
A 125 MHz 1 GIPS at 1.3 V 1 W microprocessor with single-chip tightly-coupled multiprocessor architecture and low-voltage circuits is targeted to high-performance and low-power embedded systems, especially smart information terminals. This paper shows an entire chip diagram integrating four tightly-coupled processors. Each processing element (PE) is in-order two-way issue superscalar with two ALU pipelines. A power-management unit (PMU) cuts off the leakage current of each power-control domain independently using dedicated power switches.
- 1 January 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 418-419
A 1 GIPS 1 W single-chip tightly-coupled four-way multiprocessor with architecture support for multiple control flow execution
A 125 MHz 1 GIPS at 1.3 V 1 W microprocessor with single-chip tightly-coupled multiprocessor architecture and low-voltage circuits is targeted to high-performance and low-power embedded systems, especially smart information terminals. This paper shows an entire chip diagram integrating four tightly-coupled processors. Each processing element (PE) is in-order two-way issue superscalar with two ALU pipelines. A power-management unit (PMU) cuts off the leakage current of each power-control domain independently using dedicated power switches.