AYAtsushi Yamamoto

Atsushi Yamamoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Atsushi Yamamoto has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection

    by Tomoko Kemmei, Azusa Yudo, Shuji Kodama, Atsushi Yamamoto, Yoshinori Inoue, Shigehiro Kagaya, Kazuichi Hayakawa

    We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract


  • Correlation of theophylline levels in rat exhaled breath and lung tissue after its intravenous injection

    by Miyoko Matsushima, Souma Tanihata, Junpei Kusakabe, Momoha Okahira, Hiroshi Ito, Atsushi Yamamoto, Masanori Yamamoto, Ryohei Yamamoto, Tsutomu Kawabe

    It is important to know the drug level in the target tissue to determine its dose. Some methods rely on blood levels of a drug to estimate its concentration in the tissues, which can be inaccurate. We thought that drug levels in exhaled breath aerosol (EBA) to give a more accurate value of the level of a test drug in the lung. Rats were intravenously injected with the bronchodilator theophylline and exhaled breath was collected up to 10–20 min after administration. Immediately after breath collection, lung, liver, kidney, and blood were collected and the pharmacokinetics were examined using these samples. Awake free-moving rats were used to efficiently collect exhaled breath from rats with low tidal volume. The amount of exhaled breath of rats was estimated by the amount of exhaled water vapor, and the drug concentration in exhaled breath sample was expressed by the amount of water vapor as the denominator. By using the active sampling method in which the adsorbent is sucked by a pump, theophylline in rat exhaled breath could be measured accurately. When the correlation of theophylline concentration in each sample was examined, a high correlation ( r 2 = 0.74) was found only in exhaled breath and lung tissue. EBA was considered better than blood in pharmacokinetic analysis of lung tissue.


  • Open Access

    Probing the Entropic Effect in Molecular Noncovalent Interactions between Resin‐Bound Polybrominated Arenes and Small Substrates

    by Masanori Yamamoto, Miyuki Obara, Keisuke Ochi, Atsushi Yamamoto, Katsuhiko Takenaka, Tsunehiro Tanaka, Kazunori Sato

    The associative interaction between resin‐bound polybrominated arenes and small molecules was analyzed by using various spectroscopic techniques as well as a synthetic molecular model to establish the thermodynamics. The binding in acetonitrile was three orders of magnitude stronger than that in methanol, partly owing to the tertiary conformational gating of the resin that controls the entropic terms. By using the entropic superiority, the associative binding of up to 3×104 m−1 is achieved with the non‐biological system. A modified Hill plot for the quantitative analysis of bindings was also devised, which enabled the interactions at the molecular level to be elucidated.


  • Design and development of a suitable adsorbent to capture theophylline for non-invasive therapeutic drug monitoring with exhaled breath

    by A. Yamamoto, S. Hioki, C. Tanada, T. Miwa, Y. Inoue, M. Matsushima, T. Kawabe

    The possibility of using exhaled breath as a substitute for blood/plasma in areas of therapeutic drug monitoring was investigated.


  • Open Access

    Retention of Halogenated Solutes on Stationary Phases Containing Heavy Atoms

    by Toshio Miwa, Atsushi Yamamoto, Mitsuru Saito, Yoshinori Inoue

    To examine the effects of weak intermolecular interactions on solid-phase extraction (SPE) and chromatographic separation, we synthesized some novel stationary phases with a heavy atom effect layer by immobilizing halogenated aromatic rings and hydroxyl groups onto the surface of a hydrophilic base polymer. Using SPE cartridges packed with the functionalized materials, we found that the heavy atom stationary phases could selectively retain halophenols in organic solvents, such as 1-propanol which blocks the hydrogen bonding, or acetonitrile which blocks the p-p interaction. The extraction efficiency of the materials toward the halophenols depended on the dipole moments of phenoxy groups present as functional groups. On the other hand, the extraction efficiency of solutes toward the functional group depended on their molar refractions, i.e., induced dipole moments. The retention of the solutes to the stationary phase ultimately depended on not only strong intermolecular interactions, but also the effects of weak interactions such as the dispersion force.


  • An optosensing device for detecting tetracyclineantibiotics in honey

    by Atsushi Yamamoto, Saori Yoshii, Chikako Suematsu, Michiya Tatematsu, Hidenori Shoji, Yuji Kato, Mitsuru Saito, Yoshinori Inoue

    Here we describe a simple solid phase fluorescence method for measuring tetracycline antibiotics (TCs) in honey. The device consists of an LED, a cartridge holder, and a photo-diode detector. A 5 g portion of honey was extracted with acetonitrile. To obtain acceptable cleanliness levels, the extract was cleaned up with two successive solid phase extraction steps using a cation exchanger and a reversed-phase resin. TCs in the clean-up solution were selectively adsorbed to a sulfobetaine resin. The resin was washed and irradiated with near UV, resulting in the emission of visible light. When honey samples were spiked with TC at a concentration of 0.3 μg g−1, the recovery was 90% with a RSD of 19% (n = 14). The system provides a simple, rapid and quantitative analysis of antibiotics in honey samples within 30 min.


  • Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on‐line solid‐phase extraction technique

    by Kazuhisa Uchiyama, Mari Kondo, Rika Yokochi, Yuri Takeuchi, Atsushi Yamamoto, Yoshinori Inoue

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on‐line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two‐dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second‐derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60–103%) with adequate sensitivity for TMP monitoring in honey samples.


  • Open Access

    Development of a Variable-wavelength Optical Rotation Detector in the Ultraviolet Region

    by Atsushi Yamamoto, Toshio Miwa, Mio Kawai, Toshiyasu Tadokoro, Koichi Tsutsumi, Takanobu Sato, Shuji Kodama, Kazuichi Hayakawa

    A new type of optical rotation (OR) detector based on the phase retardation of the first-order diffraction beam has been constructed. The proposed detector responded to only OR properties by eliminating the circular dichroism (CD) effect. Thus, it could measure the optical rotatory dispersion curves in the Cotton band. Although the optical system requires the incident beam in which the phase retardation is 0.5π, the actual retardation was estimated to be around 0.3π. It means that the OR signal intensity can be doubled. Since the proposed detector works over a range of UV wavelengths, there was a compound whose OR signal intensity was higher than the CD signal intensity. The OR detection was superior to CD in stability and in defining the baseline.

  • Determination of Adulteration in Apple Juice by HPLC with Novel Optical Rotation Detector

    by Atsushi Yamamoto, Mio Kawai, Toshio Miwa, Tomoyasu Tsukamoto, Shuji Kodama, Kazuichi Hayakawa

    A simple HPLC method for the determination of adulteration in apple juice was developed. The method is based on the detection of D-malate, derived from racemic malic acid, which is added as an acidulant. A variable-wavelength optical rotation detector was used to determine the enantiomeric excess (ee). Using anion-exchange chromatography with a phosphate buffer eluent and UV (210 nm) detection, the limit of detection for L-malate was 2 microg. With an injection of 13.4 microg of malate, the standard deviation of the ee calibration curve was 2.5%. Several apple juice samples were analyzed according to the proposed procedure, and the results agreed with those obtained using enzymatic kits for food analysis.