Atsushi Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Atsushi Yamamoto has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Mio Kawai
College of Bioscience and Biotechnology, Chubu University
3 shared publicationsKazuichi Hayakawa
Graduate School of Natural Science and Technology, Kanazawa University
2 shared publications- Kazuichi Hayakawa
Kanazawa University
2 shared publications Shuji Kodama
Toyama Institute of Health
2 shared publications- Shuji Kodama
Department of Chemistry, School of Science, Tokai University, Hiratsuka, Japan
2 shared publications Souma Tanihata
College of Bioscience and Biotechnology, Chubu University, 1200, Matsumoto-cho, Kasugai, Aichi 487-8501, Japan
2 shared publications
Latest Publications
- 23 February 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (6) , 885-890
Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection
We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract
- 23 February 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (6) , 885-890
Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection
We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract
- 24 May 2022
- Published by IOP Publishing in Journal of Breath Research
- Vol. 16 (3) , 036003
Correlation of theophylline levels in rat exhaled breath and lung tissue after its intravenous injection
It is important to know the drug level in the target tissue to determine its dose. Some methods rely on blood levels of a drug to estimate its concentration in the tissues, which can be inaccurate. We thought that drug levels in exhaled breath aerosol (EBA) to give a more accurate value of the level of a test drug in the lung. Rats were intravenously injected with the bronchodilator theophylline and exhaled breath was collected up to 10–20 min after administration. Immediately after breath collection, lung, liver, kidney, and blood were collected and the pharmacokinetics were examined using these samples. Awake free-moving rats were used to efficiently collect exhaled breath from rats with low tidal volume. The amount of exhaled breath of rats was estimated by the amount of exhaled water vapor, and the drug concentration in exhaled breath sample was expressed by the amount of water vapor as the denominator. By using the active sampling method in which the adsorbent is sucked by a pump, theophylline in rat exhaled breath could be measured accurately. When the correlation of theophylline concentration in each sample was examined, a high correlation ( r 2 = 0.74) was found only in exhaled breath and lung tissue. EBA was considered better than blood in pharmacokinetic analysis of lung tissue.
- 24 May 2022
- Published by IOP Publishing in Journal of Breath Research
- Vol. 16 (3) , 036003
Correlation of theophylline levels in rat exhaled breath and lung tissue after its intravenous injection
It is important to know the drug level in the target tissue to determine its dose. Some methods rely on blood levels of a drug to estimate its concentration in the tissues, which can be inaccurate. We thought that drug levels in exhaled breath aerosol (EBA) to give a more accurate value of the level of a test drug in the lung. Rats were intravenously injected with the bronchodilator theophylline and exhaled breath was collected up to 10–20 min after administration. Immediately after breath collection, lung, liver, kidney, and blood were collected and the pharmacokinetics were examined using these samples. Awake free-moving rats were used to efficiently collect exhaled breath from rats with low tidal volume. The amount of exhaled breath of rats was estimated by the amount of exhaled water vapor, and the drug concentration in exhaled breath sample was expressed by the amount of water vapor as the denominator. By using the active sampling method in which the adsorbent is sucked by a pump, theophylline in rat exhaled breath could be measured accurately. When the correlation of theophylline concentration in each sample was examined, a high correlation ( r 2 = 0.74) was found only in exhaled breath and lung tissue. EBA was considered better than blood in pharmacokinetic analysis of lung tissue.
- 14 October 2020
- Published by Springer Nature in Food Analytical Methods
- Vol. 14 (2) , 290-299
Development of a Size-Exclusion/Ion-Exclusion/Reversed-Phase Separation Method for the Simultaneous Determination of Inorganic and Organic Acids, Sugars, and Ethanol During Multiple Parallel Fermentation of Rice Wine
- 14 October 2020
- Published by Springer Nature in Food Analytical Methods
- Vol. 14 (2) , 290-299
Development of a Size-Exclusion/Ion-Exclusion/Reversed-Phase Separation Method for the Simultaneous Determination of Inorganic and Organic Acids, Sugars, and Ethanol During Multiple Parallel Fermentation of Rice Wine
- Open Access
- 9 July 2018
- Published by Wiley in Chempluschem
- Vol. 83 (9) , 820-824
Probing the Entropic Effect in Molecular Noncovalent Interactions between Resin‐Bound Polybrominated Arenes and Small Substrates
The associative interaction between resin‐bound polybrominated arenes and small molecules was analyzed by using various spectroscopic techniques as well as a synthetic molecular model to establish the thermodynamics. The binding in acetonitrile was three orders of magnitude stronger than that in methanol, partly owing to the tertiary conformational gating of the resin that controls the entropic terms. By using the entropic superiority, the associative binding of up to 3×104 m−1 is achieved with the non‐biological system. A modified Hill plot for the quantitative analysis of bindings was also devised, which enabled the interactions at the molecular level to be elucidated.
- 9 July 2018
- Published by Wiley in Chempluschem
- Vol. 83 (9) , 820-824
Open AccessProbing the Entropic Effect in Molecular Noncovalent Interactions between Resin‐Bound Polybrominated Arenes and Small Substrates
The associative interaction between resin‐bound polybrominated arenes and small molecules was analyzed by using various spectroscopic techniques as well as a synthetic molecular model to establish the thermodynamics. The binding in acetonitrile was three orders of magnitude stronger than that in methanol, partly owing to the tertiary conformational gating of the resin that controls the entropic terms. By using the entropic superiority, the associative binding of up to 3×104 m−1 is achieved with the non‐biological system. A modified Hill plot for the quantitative analysis of bindings was also devised, which enabled the interactions at the molecular level to be elucidated.
- 14 November 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (2) , 423-427
Design and development of a suitable adsorbent to capture theophylline for non-invasive therapeutic drug monitoring with exhaled breath
The possibility of using exhaled breath as a substitute for blood/plasma in areas of therapeutic drug monitoring was investigated.
- 14 November 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (2) , 423-427
Design and development of a suitable adsorbent to capture theophylline for non-invasive therapeutic drug monitoring with exhaled breath
The possibility of using exhaled breath as a substitute for blood/plasma in areas of therapeutic drug monitoring was investigated.
- Open Access
Retention of Halogenated Solutes on Stationary Phases Containing Heavy Atoms
To examine the effects of weak intermolecular interactions on solid-phase extraction (SPE) and chromatographic separation, we synthesized some novel stationary phases with a heavy atom effect layer by immobilizing halogenated aromatic rings and hydroxyl groups onto the surface of a hydrophilic base polymer. Using SPE cartridges packed with the functionalized materials, we found that the heavy atom stationary phases could selectively retain halophenols in organic solvents, such as 1-propanol which blocks the hydrogen bonding, or acetonitrile which blocks the p-p interaction. The extraction efficiency of the materials toward the halophenols depended on the dipole moments of phenoxy groups present as functional groups. On the other hand, the extraction efficiency of solutes toward the functional group depended on their molar refractions, i.e., induced dipole moments. The retention of the solutes to the stationary phase ultimately depended on not only strong intermolecular interactions, but also the effects of weak interactions such as the dispersion force.
Open AccessRetention of Halogenated Solutes on Stationary Phases Containing Heavy Atoms
To examine the effects of weak intermolecular interactions on solid-phase extraction (SPE) and chromatographic separation, we synthesized some novel stationary phases with a heavy atom effect layer by immobilizing halogenated aromatic rings and hydroxyl groups onto the surface of a hydrophilic base polymer. Using SPE cartridges packed with the functionalized materials, we found that the heavy atom stationary phases could selectively retain halophenols in organic solvents, such as 1-propanol which blocks the hydrogen bonding, or acetonitrile which blocks the p-p interaction. The extraction efficiency of the materials toward the halophenols depended on the dipole moments of phenoxy groups present as functional groups. On the other hand, the extraction efficiency of solutes toward the functional group depended on their molar refractions, i.e., induced dipole moments. The retention of the solutes to the stationary phase ultimately depended on not only strong intermolecular interactions, but also the effects of weak interactions such as the dispersion force.
- 12 December 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (3) , 773-777
An optosensing device for detecting tetracyclineantibiotics in honey
Here we describe a simple solid phase fluorescence method for measuring tetracycline antibiotics (TCs) in honey. The device consists of an LED, a cartridge holder, and a photo-diode detector. A 5 g portion of honey was extracted with acetonitrile. To obtain acceptable cleanliness levels, the extract was cleaned up with two successive solid phase extraction steps using a cation exchanger and a reversed-phase resin. TCs in the clean-up solution were selectively adsorbed to a sulfobetaine resin. The resin was washed and irradiated with near UV, resulting in the emission of visible light. When honey samples were spiked with TC at a concentration of 0.3 μg g−1, the recovery was 90% with a RSD of 19% (n = 14). The system provides a simple, rapid and quantitative analysis of antibiotics in honey samples within 30 min.
- 12 December 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (3) , 773-777
An optosensing device for detecting tetracyclineantibiotics in honey
Here we describe a simple solid phase fluorescence method for measuring tetracycline antibiotics (TCs) in honey. The device consists of an LED, a cartridge holder, and a photo-diode detector. A 5 g portion of honey was extracted with acetonitrile. To obtain acceptable cleanliness levels, the extract was cleaned up with two successive solid phase extraction steps using a cation exchanger and a reversed-phase resin. TCs in the clean-up solution were selectively adsorbed to a sulfobetaine resin. The resin was washed and irradiated with near UV, resulting in the emission of visible light. When honey samples were spiked with TC at a concentration of 0.3 μg g−1, the recovery was 90% with a RSD of 19% (n = 14). The system provides a simple, rapid and quantitative analysis of antibiotics in honey samples within 30 min.
- 13 May 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (13) , 1525-1530
Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on‐line solid‐phase extraction technique
A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on‐line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two‐dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second‐derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60–103%) with adequate sensitivity for TMP monitoring in honey samples.
- 13 May 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (13) , 1525-1530
Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on‐line solid‐phase extraction technique
A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on‐line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two‐dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second‐derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60–103%) with adequate sensitivity for TMP monitoring in honey samples.
- Open Access
- 1 January 2011
- Published by Japan Society for Analytical Chemistry in Analytical Sciences
- Vol. 27 (8) , 799
Development of a Variable-wavelength Optical Rotation Detector in the Ultraviolet Region
A new type of optical rotation (OR) detector based on the phase retardation of the first-order diffraction beam has been constructed. The proposed detector responded to only OR properties by eliminating the circular dichroism (CD) effect. Thus, it could measure the optical rotatory dispersion curves in the Cotton band. Although the optical system requires the incident beam in which the phase retardation is 0.5π, the actual retardation was estimated to be around 0.3π. It means that the OR signal intensity can be doubled. Since the proposed detector works over a range of UV wavelengths, there was a compound whose OR signal intensity was higher than the CD signal intensity. The OR detection was superior to CD in stability and in defining the baseline.
- 1 January 2011
- Published by Japan Society for Analytical Chemistry in Analytical Sciences
- Vol. 27 (8) , 799
Open AccessDevelopment of a Variable-wavelength Optical Rotation Detector in the Ultraviolet Region
A new type of optical rotation (OR) detector based on the phase retardation of the first-order diffraction beam has been constructed. The proposed detector responded to only OR properties by eliminating the circular dichroism (CD) effect. Thus, it could measure the optical rotatory dispersion curves in the Cotton band. Although the optical system requires the incident beam in which the phase retardation is 0.5π, the actual retardation was estimated to be around 0.3π. It means that the OR signal intensity can be doubled. Since the proposed detector works over a range of UV wavelengths, there was a compound whose OR signal intensity was higher than the CD signal intensity. The OR detection was superior to CD in stability and in defining the baseline.
- 18 July 2008
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 56 (16) , 7302-7304
Determination of Adulteration in Apple Juice by HPLC with Novel Optical Rotation Detector
A simple HPLC method for the determination of adulteration in apple juice was developed. The method is based on the detection of D-malate, derived from racemic malic acid, which is added as an acidulant. A variable-wavelength optical rotation detector was used to determine the enantiomeric excess (ee). Using anion-exchange chromatography with a phosphate buffer eluent and UV (210 nm) detection, the limit of detection for L-malate was 2 microg. With an injection of 13.4 microg of malate, the standard deviation of the ee calibration curve was 2.5%. Several apple juice samples were analyzed according to the proposed procedure, and the results agreed with those obtained using enzymatic kits for food analysis.
- 18 July 2008
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 56 (16) , 7302-7304
Determination of Adulteration in Apple Juice by HPLC with Novel Optical Rotation Detector
A simple HPLC method for the determination of adulteration in apple juice was developed. The method is based on the detection of D-malate, derived from racemic malic acid, which is added as an acidulant. A variable-wavelength optical rotation detector was used to determine the enantiomeric excess (ee). Using anion-exchange chromatography with a phosphate buffer eluent and UV (210 nm) detection, the limit of detection for L-malate was 2 microg. With an injection of 13.4 microg of malate, the standard deviation of the ee calibration curve was 2.5%. Several apple juice samples were analyzed according to the proposed procedure, and the results agreed with those obtained using enzymatic kits for food analysis.