Yue Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yue Pan has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Weibao Qiu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
5 shared publications Xingying Wang
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
5 shared publicationsYu Qiang
4 shared publications- Zhiqiang Zhang
Shenzhen Institutes of Advanced Technology and Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, and State Key Laboratory of Biomedical Imaging Science and System, Shenzhen, China
4 shared publications Rong Liu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
3 shared publications- Xiao He
State Key Laboratory of Acoustic, Institute of Acoustics, Chinese Academy of Sciences, Beijing, China
3 shared publications
Latest Publications
- 2 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (17) , 175008
A three-phase poroelastic-scattering model for skull ultrasound transmission and effective porosity inversion
Transcranial ultrasound is increasingly used in brain imaging, neuromodulation, and therapy guidance, but its performance is severely degraded by the skull, whose porous and heterogeneous microstructure induces strong attenuation, scattering, and phase distortion in the MHz range. However, skull-induced transmission loss is still commonly handled empirically, and its quantitative relationship to interpretable microstructural descriptors remains poorly established. In this work, we develop a three-phase poroelastic-scattering model for porous cranial bone , comprising a mineralized matrix, a trabecular/cellular solid component within the pore space, and pore fluid. The model combines a Bruggeman-type effective-medium formulation for elastic properties, Biot–Johnson–Koplik–Dashen dynamic viscous coupling, and a Rayleigh-type scattering term to describe frequency-dependent transmission loss. Numerical analysis shows that the fast compressional mode exhibits a characteristic dependence on frequency and porosity, with attenuation governed jointly by viscous/tortuosity losses and microstructural scattering, while phase velocity is dominated by effective stiffness. The model was calibrated using through-transmission measurements on 3D-printed porous epoxy–alumina phantoms with porosities ranging from 10% to 40%, and was subsequently applied to ex vivo rat and monkey skulls to estimate local effective porosity from the apparent attenuation evaluated at representative analysis frequencies. For the monkey skull, the ultrasound-derived estimates were consistent with the CT-derived apparent porosity obtained from the same specimen. These results support a microstructure-informed parameterization of skull transmission loss and provide a quantitative basis for skull-aware propagation modeling and compensation in transcranial ultrasound.
- 2 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (17) , 175008
A three-phase poroelastic-scattering model for skull ultrasound transmission and effective porosity inversion
Transcranial ultrasound is increasingly used in brain imaging, neuromodulation, and therapy guidance, but its performance is severely degraded by the skull, whose porous and heterogeneous microstructure induces strong attenuation, scattering, and phase distortion in the MHz range. However, skull-induced transmission loss is still commonly handled empirically, and its quantitative relationship to interpretable microstructural descriptors remains poorly established. In this work, we develop a three-phase poroelastic-scattering model for porous cranial bone , comprising a mineralized matrix, a trabecular/cellular solid component within the pore space, and pore fluid. The model combines a Bruggeman-type effective-medium formulation for elastic properties, Biot–Johnson–Koplik–Dashen dynamic viscous coupling, and a Rayleigh-type scattering term to describe frequency-dependent transmission loss. Numerical analysis shows that the fast compressional mode exhibits a characteristic dependence on frequency and porosity, with attenuation governed jointly by viscous/tortuosity losses and microstructural scattering, while phase velocity is dominated by effective stiffness. The model was calibrated using through-transmission measurements on 3D-printed porous epoxy–alumina phantoms with porosities ranging from 10% to 40%, and was subsequently applied to ex vivo rat and monkey skulls to estimate local effective porosity from the apparent attenuation evaluated at representative analysis frequencies. For the monkey skull, the ultrasound-derived estimates were consistent with the CT-derived apparent porosity obtained from the same specimen. These results support a microstructure-informed parameterization of skull transmission loss and provide a quantitative basis for skull-aware propagation modeling and compensation in transcranial ultrasound.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
A Dual-mode Ultrasound Transducer Based on Textured Ceramic for Image-guided Interstitial Ablationn
Ultrasound image-guided interstitial ablation is an economical and effective way in the management of unresectable tumors and other pathologically compromised tissues. However, in clinical practice, extracorporeal ultrasound imaging guidance presents challenges in target localization, while interstitial ultrasound imaging increases system complexity. The integrated dual-mode transducer that combines imaging and therapeutic capabilities emerges as an optimal solution. Due to inherent limitations of piezoelectric materials-such as the trade-offs among piezoelectric and dielectric properties-conventional dual-mode transducers generally face a compromise between imaging quality and ablation efficacy. To address these technical challenges, we have developed a miniature dual-mode ultrasound transducer based on a novel textured Pb(In1/2Nb1/2)O3-Pb(Sc1/2Nb1/2)O3-PbTiO3 (PIN-PSN-PT) ceramic with superior performance in both ultrasound imaging and therapeutic ablation. The proposed dual-mode transducer exhibited a center frequency of 6.84 MHz along with a broad fractional bandwidth of 92%. An ultrahigh negative acoustic pressure of 2.9 MPa was obtained under an excitation voltage of 50 Vpp with corresponding spatial-peak pulse-average intensity of 272.6 W·cm-2. This work presents a paradigm for high-performance dual-mode transducer and highlights the potential of textured PIN-PSN-PT ceramic for integrated diagnostic imaging and therapeutic applications. These results provide essential technical support for future clinical translation.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
A Dual-mode Ultrasound Transducer Based on Textured Ceramic for Image-guided Interstitial Ablationn
Ultrasound image-guided interstitial ablation is an economical and effective way in the management of unresectable tumors and other pathologically compromised tissues. However, in clinical practice, extracorporeal ultrasound imaging guidance presents challenges in target localization, while interstitial ultrasound imaging increases system complexity. The integrated dual-mode transducer that combines imaging and therapeutic capabilities emerges as an optimal solution. Due to inherent limitations of piezoelectric materials-such as the trade-offs among piezoelectric and dielectric properties-conventional dual-mode transducers generally face a compromise between imaging quality and ablation efficacy. To address these technical challenges, we have developed a miniature dual-mode ultrasound transducer based on a novel textured Pb(In1/2Nb1/2)O3-Pb(Sc1/2Nb1/2)O3-PbTiO3 (PIN-PSN-PT) ceramic with superior performance in both ultrasound imaging and therapeutic ablation. The proposed dual-mode transducer exhibited a center frequency of 6.84 MHz along with a broad fractional bandwidth of 92%. An ultrahigh negative acoustic pressure of 2.9 MPa was obtained under an excitation voltage of 50 Vpp with corresponding spatial-peak pulse-average intensity of 272.6 W·cm-2. This work presents a paradigm for high-performance dual-mode transducer and highlights the potential of textured PIN-PSN-PT ceramic for integrated diagnostic imaging and therapeutic applications. These results provide essential technical support for future clinical translation.
- 16 October 2025
- Published by Elsevier in Ultrasonics
- Vol. 159, 107860
High-precision wavefield simulation and deep learning-based sound speed reconstruction for transcranial ultrasound imaging
- 16 October 2025
- Published by Elsevier in Ultrasonics
- Vol. 159, 107860
High-precision wavefield simulation and deep learning-based sound speed reconstruction for transcranial ultrasound imaging
- 20 July 2024
- Published by Elsevier in Ultrasonics
- Vol. 143, 107405
A transcranial multiple waves suppression method for plane wave imaging based on Radon transform
- 20 July 2024
- Published by Elsevier in Ultrasonics
- Vol. 143, 107405
A transcranial multiple waves suppression method for plane wave imaging based on Radon transform
- 22 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (5) , 1628-1639
A New Method of Plane-Wave Ultrasound Imaging Based on Reverse Time Migration
Coherent plane-wave compounding technique enables rapid ultrasound imaging with comparable image quality to traditional B-mode imaging that relies on focused beam transmission. However, existing methods assume homogeneity in the imaged medium, neglecting the heterogeneity in sound velocities and densities present in real tissues, resulting in noise reverberation. This study introduces the Reverse Time Migration (RTM) method for ultrasound plane-wave imaging to overcome this limitation, which is combined with a method for estimating the speed of sound in layered media. Simulation results in a homogeneous background demonstrate that RTM reduces side lobes and grating lobes by approximately 30 dB, enhancing the contrast-to-noise ratio by 20% compared to conventional delay and sum (DAS) beamforming. Moreover, RTM achieves superior imaging outcomes with fewer compounding angles. The lateral resolution of the RTM with 5–9 angle compounding is able to achieve the effectiveness of the DAS method with 15–19 angle compounding, and the CNR of the RTM with 11-angle compounding is almost the same as that of the DAS with 21-angle compounding. In a heterogeneous background, experimental simulations and in vitro wire phantom experiments confirm RTM's capability to correct depth imaging, focusing reflected waves on point targets. In vitro porcine tissue experiments enable accurate imaging of layer interfaces by estimating the velocities of multiple layers containing muscle and fat. The proposed imaging procedure optimizes velocity estimation in complex media, compensates for the impact of velocity differences, provides more reliable imaging results.
- 22 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (5) , 1628-1639
A New Method of Plane-Wave Ultrasound Imaging Based on Reverse Time Migration
Coherent plane-wave compounding technique enables rapid ultrasound imaging with comparable image quality to traditional B-mode imaging that relies on focused beam transmission. However, existing methods assume homogeneity in the imaged medium, neglecting the heterogeneity in sound velocities and densities present in real tissues, resulting in noise reverberation. This study introduces the Reverse Time Migration (RTM) method for ultrasound plane-wave imaging to overcome this limitation, which is combined with a method for estimating the speed of sound in layered media. Simulation results in a homogeneous background demonstrate that RTM reduces side lobes and grating lobes by approximately 30 dB, enhancing the contrast-to-noise ratio by 20% compared to conventional delay and sum (DAS) beamforming. Moreover, RTM achieves superior imaging outcomes with fewer compounding angles. The lateral resolution of the RTM with 5–9 angle compounding is able to achieve the effectiveness of the DAS method with 15–19 angle compounding, and the CNR of the RTM with 11-angle compounding is almost the same as that of the DAS with 21-angle compounding. In a heterogeneous background, experimental simulations and in vitro wire phantom experiments confirm RTM's capability to correct depth imaging, focusing reflected waves on point targets. In vitro porcine tissue experiments enable accurate imaging of layer interfaces by estimating the velocities of multiple layers containing muscle and fat. The proposed imaging procedure optimizes velocity estimation in complex media, compensates for the impact of velocity differences, provides more reliable imaging results.
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 831-840
A Multiplexed 32 × 32 2D Matrix Array Transducer for Flexible Sub-Aperture Volumetric Ultrasound Imaging
A fully-sampled two-dimensional (2D) matrix array ultrasonic transducer is essential for fast and accurate three-dimensional (3D) volumetric ultrasound imaging. However, these arrays, usually consisting of thousands of elements, not only face challenges of poor performance and complex wiring due to high-density elements and small element sizes but also put high requirements for electronic systems. Current commercially available fully-sampled matrix arrays, dividing the aperture into four fixed sub-apertures to reduce system channels through multiplexing are widely used. However, the fixed sub-aperture configuration limits imaging flexibility and the gaps between sub-apertures lead to reduced imaging quality. In this study, we propose a high-performance multiplexed matrix array by the design of 1-3 piezocomposite and gapless sub-aperture configuration, as well as optimized matching layer materials. Furthermore, we introduce a sub-aperture volumetric imaging method based on the designed matrix array, enabling high-quality and flexible 3D ultrasound imaging with a low-cost 256-channel system. The influence of imaging parameters, including the number of sub-apertures and steering angle on imaging quality was investigated by simulation, in vitro, and in vivo imaging experiments. The fabricated matrix array has a center frequency of 3.4 MHz and a -6dB bandwidth above 70%. The proposed sub-aperture volumetric imaging method demonstrated a 10% improvement in spatial resolution, a 19% increase in signal-to-noise ratio, and a 57.7% increase in contrast-to-noise ratio compared with the fixed sub-aperture array imaging method. This study provides a new strategy for high-quality volumetric ultrasound imaging with a low-cost system.
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 831-840
A Multiplexed 32 × 32 2D Matrix Array Transducer for Flexible Sub-Aperture Volumetric Ultrasound Imaging
A fully-sampled two-dimensional (2D) matrix array ultrasonic transducer is essential for fast and accurate three-dimensional (3D) volumetric ultrasound imaging. However, these arrays, usually consisting of thousands of elements, not only face challenges of poor performance and complex wiring due to high-density elements and small element sizes but also put high requirements for electronic systems. Current commercially available fully-sampled matrix arrays, dividing the aperture into four fixed sub-apertures to reduce system channels through multiplexing are widely used. However, the fixed sub-aperture configuration limits imaging flexibility and the gaps between sub-apertures lead to reduced imaging quality. In this study, we propose a high-performance multiplexed matrix array by the design of 1-3 piezocomposite and gapless sub-aperture configuration, as well as optimized matching layer materials. Furthermore, we introduce a sub-aperture volumetric imaging method based on the designed matrix array, enabling high-quality and flexible 3D ultrasound imaging with a low-cost 256-channel system. The influence of imaging parameters, including the number of sub-apertures and steering angle on imaging quality was investigated by simulation, in vitro, and in vivo imaging experiments. The fabricated matrix array has a center frequency of 3.4 MHz and a -6dB bandwidth above 70%. The proposed sub-aperture volumetric imaging method demonstrated a 10% improvement in spatial resolution, a 19% increase in signal-to-noise ratio, and a 57.7% increase in contrast-to-noise ratio compared with the fixed sub-aperture array imaging method. This study provides a new strategy for high-quality volumetric ultrasound imaging with a low-cost system.
- Open Access
- 24 May 2022
- Published by Oxford University Press (OUP) in Journal of Geophysics and Engineering
- Vol. 19 (3) , 295-315
Q-compensated viscoelastic reverse time migration in crosswell seismic imaging
Viscoelastic reverse time migration (RTM) is a practical approach to compensats for attenuation effects in migration, commonly studied in surface seismic research. Compared with conventional surface seismic imaging, the sources and receivers of crosswell seismic imaging are distributed in different wells with higher main frequencies and lower surface noises. The finer structures can be imaged. In this paper, we apply attenuation compensated RTM in crosswell migration to improve the resolution of images in attenuation regions. We solve the viscoelastic equations using the constant Q model because of its advantage of decoupling the amplitude and phase. The fractional-order amplitude and phase Laplacian operators are used. By spectral ration techniques, we observe the relationship between attenuation and frequency in crosswell seismic imaging. We describe the alignment and muting of direct P- and S-waves from full waves in detail. Synthetic examples demonstrate that Q-RTM images the geological structure more clearly than the traditional RTM. We reveal that compensated images describe the three-layer model, tilted fractures and randomly distributed caves more accurately. As the tilted angles increase, only two end points of the tilted fracture can be identified by conventional RTM, the boundary is blurred. We find that caves far from the source well can barely be imaged. By comparison, the compensated RTM approach obtains precise migration results of tilted fractures with arbitrary dip angles and caves. Finally, to approximate the real measurement data, noise is added to the viscoelastic data of the five-layer model. The effective noise immunity in crosswell seismic applications is verified.
- 24 May 2022
- Published by Oxford University Press (OUP) in Journal of Geophysics and Engineering
- Vol. 19 (3) , 295-315
Open AccessQ-compensated viscoelastic reverse time migration in crosswell seismic imaging
Viscoelastic reverse time migration (RTM) is a practical approach to compensats for attenuation effects in migration, commonly studied in surface seismic research. Compared with conventional surface seismic imaging, the sources and receivers of crosswell seismic imaging are distributed in different wells with higher main frequencies and lower surface noises. The finer structures can be imaged. In this paper, we apply attenuation compensated RTM in crosswell migration to improve the resolution of images in attenuation regions. We solve the viscoelastic equations using the constant Q model because of its advantage of decoupling the amplitude and phase. The fractional-order amplitude and phase Laplacian operators are used. By spectral ration techniques, we observe the relationship between attenuation and frequency in crosswell seismic imaging. We describe the alignment and muting of direct P- and S-waves from full waves in detail. Synthetic examples demonstrate that Q-RTM images the geological structure more clearly than the traditional RTM. We reveal that compensated images describe the three-layer model, tilted fractures and randomly distributed caves more accurately. As the tilted angles increase, only two end points of the tilted fracture can be identified by conventional RTM, the boundary is blurred. We find that caves far from the source well can barely be imaged. By comparison, the compensated RTM approach obtains precise migration results of tilted fractures with arbitrary dip angles and caves. Finally, to approximate the real measurement data, noise is added to the viscoelastic data of the five-layer model. The effective noise immunity in crosswell seismic applications is verified.
- 17 January 2019
- Published by Springer Nature
- p. 862-869
Sampling Redundancy Removal Algorithms for Stepped Frequency Continuous Wave
- 17 January 2019
- Published by Springer Nature
- p. 862-869
Sampling Redundancy Removal Algorithms for Stepped Frequency Continuous Wave