Fergio Sismono
Research Subjects
Fergio Sismono has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Zarowski
European Institute for ORL-HNS, Sint-Augustinus Hospital Antwerp, Wilrijk, Belgium
4 shared publications - Marc Leblans
European Institute for ORL, GZA Sint-Augustinus, Antwerp, Belgium
4 shared publications Erwin Offeciers
European Institute for ORL, GZA Sint-Augustinus, Antwerp, Belgium
2 shared publications- Lucia Mancini
Slovenian National Building and Civil Engineering Institute
2 shared publications - Alessio Veneziano
Archéozoologie, Archéobotanique: Sociétés, Pratiques et Environnements (AASPE), Muséum National D'Histoire Naturelle, CNRS Paris France
1 shared publication - Anja Bernaerts
GZA Hospitals
1 shared publication
Latest Publications
- Open Access
- 22 May 2026
- Published by Elsevier in Journal of Voice
AI-Driven Detection and Classification of Voice Disorders Using Acoustic Recordings
- 22 May 2026
- Published by Elsevier in Journal of Voice
Open AccessAI-Driven Detection and Classification of Voice Disorders Using Acoustic Recordings
- Open Access
- 1 August 2025
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5 (8)
A comparison of electrophysiological measures for characterizing the cochlear-implant electrode-neuron interface
The health of the auditory nerve is a key factor for hearing outcomes in cochlear-implant patients. Many electrophysiological markers of auditory-neural health have been proposed, with varying predictive power and independence from non-neural factors. The “Failure Index” (FI), the ratio between stimulation current level and response magnitude of the electrically-evoked compound action potential (eCAP) was compared to the Panoramic eCAP method. Both methods predicted localized areas of reduced neural responsiveness in a group of human cochlear-implant users, but the FI showed a greater dependence on a non-neural factor, namely, the distances between the cochlear-implant electrodes and the auditory nerves.
- 1 August 2025
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5 (8)
Open AccessA comparison of electrophysiological measures for characterizing the cochlear-implant electrode-neuron interface
The health of the auditory nerve is a key factor for hearing outcomes in cochlear-implant patients. Many electrophysiological markers of auditory-neural health have been proposed, with varying predictive power and independence from non-neural factors. The “Failure Index” (FI), the ratio between stimulation current level and response magnitude of the electrically-evoked compound action potential (eCAP) was compared to the Panoramic eCAP method. Both methods predicted localized areas of reduced neural responsiveness in a group of human cochlear-implant users, but the FI showed a greater dependence on a non-neural factor, namely, the distances between the cochlear-implant electrodes and the auditory nerves.
- Open Access
- 29 September 2023
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 19 (5) , 368-375
Calculation of the Faradaic Impedance of the Electrode–Tissue Interface Improves Prediction of Behavioral T/C Levels in Cochlear Implant Patients
BACKGROUND: Fitting of cochlear implants is a labor-intensive process, and therefore automated fitting procedures are being sought. The objective of this study was to evaluate if decomposition of the complex impedance of the electrode–tissue interface could provide additional parameters that show improved correlation with the behavioral T/C levels. METHODS: A new method for decomposing the complex impedance of the electrode–tissue interface was developed and tested in 18 patients in a prospective study in a tertiary otologic referral center. RESULTS: The averaged near-field Faradaic resistance (RF) calculated in study subjects shows a very strong correlation (R2=0.80) with the behavioral C levels and can be used for automated fitting in most patients. The standard deviation for the T levels and the C levels calculated for each of the electrode contacts in all study subjects is in the range of 10-15 CL and 15-20 CL, respectively. These higher values of the standard deviations are caused by a few outliers who require that additional parameters have to be added to the metric equation, allowing for the automated prediction of the T/C levels. CONCLUSION: A new method for deriving information from the electrode impedance measurements shows excellent correlation of the Faradaic resistance with the behavioral T/C levels in most patients and can be very useful for fitting cochlear implants based on objective measures. Since some patients still show discrepancies between the predicted T/C levels based on the RF calculation, additional parameters have to be added to the metric equation, allowing for automated prediction of the T/C levels. Cite this article as: Zarowski A, Leblans M, Molisz A, Sismono F, van Dinther J, Offeciers FE. Calculation of the faradaic impedance of the electrode– tissue interface improves prediction of behavioral T/C levels in cochlear implant patients. J Int Adv Otol. 2023;19(5):368-375.
- 29 September 2023
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 19 (5) , 368-375
Open AccessCalculation of the Faradaic Impedance of the Electrode–Tissue Interface Improves Prediction of Behavioral T/C Levels in Cochlear Implant Patients
BACKGROUND: Fitting of cochlear implants is a labor-intensive process, and therefore automated fitting procedures are being sought. The objective of this study was to evaluate if decomposition of the complex impedance of the electrode–tissue interface could provide additional parameters that show improved correlation with the behavioral T/C levels. METHODS: A new method for decomposing the complex impedance of the electrode–tissue interface was developed and tested in 18 patients in a prospective study in a tertiary otologic referral center. RESULTS: The averaged near-field Faradaic resistance (RF) calculated in study subjects shows a very strong correlation (R2=0.80) with the behavioral C levels and can be used for automated fitting in most patients. The standard deviation for the T levels and the C levels calculated for each of the electrode contacts in all study subjects is in the range of 10-15 CL and 15-20 CL, respectively. These higher values of the standard deviations are caused by a few outliers who require that additional parameters have to be added to the metric equation, allowing for the automated prediction of the T/C levels. CONCLUSION: A new method for deriving information from the electrode impedance measurements shows excellent correlation of the Faradaic resistance with the behavioral T/C levels in most patients and can be very useful for fitting cochlear implants based on objective measures. Since some patients still show discrepancies between the predicted T/C levels based on the RF calculation, additional parameters have to be added to the metric equation, allowing for automated prediction of the T/C levels. Cite this article as: Zarowski A, Leblans M, Molisz A, Sismono F, van Dinther J, Offeciers FE. Calculation of the faradaic impedance of the electrode– tissue interface improves prediction of behavioral T/C levels in cochlear implant patients. J Int Adv Otol. 2023;19(5):368-375.
- 21 June 2022
- Published by Elsevier in Hearing Research
- Vol. 426, 108563
Novel Impedance Measures as Biomarker for Intracochlear Fibrosis
- 21 June 2022
- Published by Elsevier in Hearing Research
- Vol. 426, 108563
Novel Impedance Measures as Biomarker for Intracochlear Fibrosis
- 25 May 2022
- Published by Elsevier in Hearing Research
- Vol. 426, 108537
3D-localisation of cochlear implant electrode contacts in relation to anatomical structures from in vivo cone-beam computed tomography
- 25 May 2022
- Published by Elsevier in Hearing Research
- Vol. 426, 108537
3D-localisation of cochlear implant electrode contacts in relation to anatomical structures from in vivo cone-beam computed tomography
- 1 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (1) , 327-332
Synchrotron radiation X-ray microtomography for the visualization of intra-cochlear anatomy in human temporal bones implanted with a perimodiolar cochlear implant electrode array
Recently, synchrotron radiation computed microtomography (SRµCT) has emerged as a promising tool for non-destructive, in situ visualization of cochlear implant electrode arrays inserted into a human cochlea. Histological techniques have been the `gold standard' technique for accurate localization of cochlear implant electrodes but are suboptimal for precise three-dimensional measurements. Here, an SRµCT experimental setup is proposed that offers the benefit of a high spatial and contrast resolution (isotropic voxel size = 4.95 µm and propagation-based phase-contrast imaging), while visualizing the soft-tissue structures and electrode array of the cochlear implant simultaneously. In this work, perimodiolar electrode arrays have been tested, which incorporate thick and closely spaced platinum–iridium contacts and wiring. These data can assist cochlear implant and hearing research, can be used to verify electrode segmentation techniques for clinical computed tomography or could be utilized to evaluate cochlear implant electrode array designs.
- 1 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (1) , 327-332
Synchrotron radiation X-ray microtomography for the visualization of intra-cochlear anatomy in human temporal bones implanted with a perimodiolar cochlear implant electrode array
Recently, synchrotron radiation computed microtomography (SRµCT) has emerged as a promising tool for non-destructive, in situ visualization of cochlear implant electrode arrays inserted into a human cochlea. Histological techniques have been the `gold standard' technique for accurate localization of cochlear implant electrodes but are suboptimal for precise three-dimensional measurements. Here, an SRµCT experimental setup is proposed that offers the benefit of a high spatial and contrast resolution (isotropic voxel size = 4.95 µm and propagation-based phase-contrast imaging), while visualizing the soft-tissue structures and electrode array of the cochlear implant simultaneously. In this work, perimodiolar electrode arrays have been tested, which incorporate thick and closely spaced platinum–iridium contacts and wiring. These data can assist cochlear implant and hearing research, can be used to verify electrode segmentation techniques for clinical computed tomography or could be utilized to evaluate cochlear implant electrode array designs.