A comparison of electrophysiological measures for characterizing the cochlear-implant electrode-neuron interface
Open Access
- 1 August 2025
- journal article
- research article
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5 (8)
Abstract
The health of the auditory nerve is a key factor for hearing outcomes in cochlear-implant patients. Many electrophysiological markers of auditory-neural health have been proposed, with varying predictive power and independence from non-neural factors. The “Failure Index” (FI), the ratio between stimulation current level and response magnitude of the electrically-evoked compound action potential (eCAP) was compared to the Panoramic eCAP method. Both methods predicted localized areas of reduced neural responsiveness in a group of human cochlear-implant users, but the FI showed a greater dependence on a non-neural factor, namely, the distances between the cochlear-implant electrodes and the auditory nerves.Keywords
All Related Versions
Funding Information
- Medical Research Council (G116517)
- Medical Research Council (MR/T03095X/1)
- Wellcome Trust (RG91976)
- Royal National Institute for Deaf People (G108648)
- Medical Research Council (G101400)
This publication has 30 references indexed in Scilit:
- Can ECAP Measures Be Used for Totally Objective Programming of Cochlear Implants?Journal of the Association for Research in Otolaryngology, 2013
- The Early History of the Cochlear ImplantJAMA Otolaryngology–Head & Neck Surgery, 2013
- Factors Affecting Auditory Performance of Postlinguistically Deaf Adults Using Cochlear Implants: An Update with 2251 PatientsAudiology and Neurotology, 2012
- Modeling the electrode–neuron interface of cochlear implants: Effects of neural survival, electrode placement, and the partial tripolar configurationHearing Research, 2010
- Probing the Electrode-Neuron Interface With Focused Cochlear Implant StimulationTrends in Amplification, 2010
- Comparison of Electrically Evoked Compound Action Potential Thresholds and Loudness Estimates for the Stimuli Used to Program the Advanced Bionics Cochlear ImplantJournal of the American Academy of Audiology, 2010
- Effect of interphase gap and pulse duration on electrically evoked potentials is correlated with auditory nerve survivalHearing Research, 2006
- Electrically Evoked Compound Action Potential Amplitude Growth Functions and HiResolution Programming Levels in Pediatric CII Implant SubjectsEar & Hearing, 2004
- Summary of Results Using the Nucleus CI24M Implant to Record the Electrically Evoked Compound Action PotentialEar & Hearing, 1999
- Calculating correlation coefficients with repeated observations: Part 2—correlation between subjectsBMJ, 1995