Marius Flügel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marius Flügel has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Waldmann
ZSW—Zentrum für Sonnenenergie- und Wasserstoff-Forschung Baden-Württemberg, 89081 Ulm, Germany
7 shared publications - Margret Wohlfahrt-Mehrens
Zentrum für Sonnenenergie- und Wasserstoff-Forschung Baden-Württemberg (ZSW), Lise-Meitner-Straße 24, 89081 Ulm, Germany
4 shared publications - Ralph Gilles
Technical University of Munich, Heinz Maier-Leibnitz Zentrum
4 shared publications - Ivana Pivarníková
Heinz Maier-Leibnitz Zentrum (MLZ), Technical University of Munich, Lichtenbergstr.1, 85748 Garching, Germany
3 shared publications - Marius Bolsinger
Materials Research Institute Aalen (IMFAA) Aalen University of Applied Sciences Beethovenstraße 1 D‐73430 Aalen Germany
3 shared publications - Neelima Paul
Heinz Maier-Leibnitz Zentrum, Technical University Munich, 85748, Garching, Germany
3 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (8) , 080539
Multi-Method Li Plating Characterization of a Commercial 26 Ah Li-Ion Pouch-Cell
Lithium (Li) plating on graphite is a significant degradation mechanism in Li-ion batteries. While numerous experimental techniques have been used to study Li plating in laboratory cells, investigations of commercial high-energy cells often rely on electrochemical methods. Here we present and classify various methods for detecting Li plating on a commercial A123 pouch cell. In a round robin study across multiple battery research laboratories, Li-plated graphitic electrode material was analyzed using electrochemical, microscopic, and spectroscopic methods capable of detecting metallic Li deposits. After cell opening, their overall distribution on the anode surface was examined using a flatbed scanner to ensure comparability of the samples. Optical and electron microscopy provided detailed surface and, in combination with a focused ion beam, subsurface structure and morphology. Spectroscopic methods confirmed the presence and onset of plated Li with varying sensitivity. Moreover, spectroscopic and imaging techniques were combined correlatively where possible. Availability and measurement duration of each technique was compared. Optical methods are fast and easy to use; thus, they are recommended for most samples, with spectroscopic confirmation reserved for reference samples. This multimodal study demonstrates a range of methods that can be used alone or in combination to qualitatively or quantitatively detect Li-plating.
- 1 July 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (8) , 080539
Open AccessMulti-Method Li Plating Characterization of a Commercial 26 Ah Li-Ion Pouch-Cell
Lithium (Li) plating on graphite is a significant degradation mechanism in Li-ion batteries. While numerous experimental techniques have been used to study Li plating in laboratory cells, investigations of commercial high-energy cells often rely on electrochemical methods. Here we present and classify various methods for detecting Li plating on a commercial A123 pouch cell. In a round robin study across multiple battery research laboratories, Li-plated graphitic electrode material was analyzed using electrochemical, microscopic, and spectroscopic methods capable of detecting metallic Li deposits. After cell opening, their overall distribution on the anode surface was examined using a flatbed scanner to ensure comparability of the samples. Optical and electron microscopy provided detailed surface and, in combination with a focused ion beam, subsurface structure and morphology. Spectroscopic methods confirmed the presence and onset of plated Li with varying sensitivity. Moreover, spectroscopic and imaging techniques were combined correlatively where possible. Availability and measurement duration of each technique was compared. Optical methods are fast and easy to use; thus, they are recommended for most samples, with spectroscopic confirmation reserved for reference samples. This multimodal study demonstrates a range of methods that can be used alone or in combination to qualitatively or quantitatively detect Li-plating.
- Open Access
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 070526
Efficient Workflows for Detecting Li Depositions in Lithium-Ion Batteries
Lithium deposition on anode surfaces can lead to fast capacity degradation and decreased safety properties of Li-ion cells. To avoid the critical aging mechanism of lithium deposition, its detection is essential. We present workflows for the efficient detection of Li deposition on electrode and cell level. The workflows are based on a variety of complementary advanced physico-chemical methods which were validated against each other for both graphite and graphite/Si electrodes: Electrochemical analysis, scanning electron microscopy, glow discharge-optical emission spectroscopy and neutron depth profiling, ex situ optical microscopy, in situ optical microscopy of cross-sectioned full cells, measurements in 3-electrode full cells, as well as 3D microstructurally resolved simulations. General considerations for workflows for analysis of battery cells and materials are discussed. The efficiency can be increased by parallel or serial execution of methods, stop criteria, and design of experiments planning. An important point in case of investigation of Li depositions are rest times during which Li can re-intercalate into the anode or react with electrolyte. Three workflows are presented to solve the questions on the occurrence of lithium deposition in an aged cell, the positions of lithium deposition in a cell, and operating conditions which avoid lithium depositions in a cell.
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 070526
Open AccessEfficient Workflows for Detecting Li Depositions in Lithium-Ion Batteries
Lithium deposition on anode surfaces can lead to fast capacity degradation and decreased safety properties of Li-ion cells. To avoid the critical aging mechanism of lithium deposition, its detection is essential. We present workflows for the efficient detection of Li deposition on electrode and cell level. The workflows are based on a variety of complementary advanced physico-chemical methods which were validated against each other for both graphite and graphite/Si electrodes: Electrochemical analysis, scanning electron microscopy, glow discharge-optical emission spectroscopy and neutron depth profiling, ex situ optical microscopy, in situ optical microscopy of cross-sectioned full cells, measurements in 3-electrode full cells, as well as 3D microstructurally resolved simulations. General considerations for workflows for analysis of battery cells and materials are discussed. The efficiency can be increased by parallel or serial execution of methods, stop criteria, and design of experiments planning. An important point in case of investigation of Li depositions are rest times during which Li can re-intercalate into the anode or react with electrolyte. Three workflows are presented to solve the questions on the occurrence of lithium deposition in an aged cell, the positions of lithium deposition in a cell, and operating conditions which avoid lithium depositions in a cell.
- Open Access
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 070503
Lithium Redistribution Mechanism within Silicon-Graphite Electrodes: Multi-Method Approach and Method Validation
Li redistribution processes within Si-graphite composite (SiG) electrodes are analyzed using in situ and operando X-ray diffraction (XRD), ex situ light microscopy (LM), in situ optical microscopy of cross-sectioned full cells (CS-IOM), and 3D microstructure-resolved simulations of full cells. First, the lithiation behavior of graphite and SiG full cells (Si content 20.8 wt.-%) is analyzed. The results are used as validation of the methods (XRD, LM, CS-IOM, simulation). Second, the Li redistribution between the graphite component and Si component within SiG electrodes is investigated: By operando XRD measurements during charging in comparison with relaxed cells, a higher lithiation degree in the graphite component is found during charging compared to the relaxed state, indicating Li redistribution from graphite to Si during relaxation. The Li redistribution is directly observed by in situ and ex situ optical microscopy, where the golden LiC6 phase disappears during a 24 h relaxation period. The results are supported by simulations showing the variation in the Li concentration, not only in graphite but also within the Si component. Furthermore, all methods find that the Li redistribution is more pronounced at a higher C-rate of 0.5 C, suggesting a preference for graphite lithiation over Si lithiation.
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 070503
Open AccessLithium Redistribution Mechanism within Silicon-Graphite Electrodes: Multi-Method Approach and Method Validation
Li redistribution processes within Si-graphite composite (SiG) electrodes are analyzed using in situ and operando X-ray diffraction (XRD), ex situ light microscopy (LM), in situ optical microscopy of cross-sectioned full cells (CS-IOM), and 3D microstructure-resolved simulations of full cells. First, the lithiation behavior of graphite and SiG full cells (Si content 20.8 wt.-%) is analyzed. The results are used as validation of the methods (XRD, LM, CS-IOM, simulation). Second, the Li redistribution between the graphite component and Si component within SiG electrodes is investigated: By operando XRD measurements during charging in comparison with relaxed cells, a higher lithiation degree in the graphite component is found during charging compared to the relaxed state, indicating Li redistribution from graphite to Si during relaxation. The Li redistribution is directly observed by in situ and ex situ optical microscopy, where the golden LiC6 phase disappears during a 24 h relaxation period. The results are supported by simulations showing the variation in the Li concentration, not only in graphite but also within the Si component. Furthermore, all methods find that the Li redistribution is more pronounced at a higher C-rate of 0.5 C, suggesting a preference for graphite lithiation over Si lithiation.
- Open Access
- 1 January 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (1) , 010510
Aging Mechanism For Calendar Aging of Li-Ion Cells With Si/Graphite Anodes
Calendar aging of Li-ion batteries with Si/graphite electrodes was investigated within this study. A total of 121 single-layer pouch full cells with either graphite or Si/graphite (3.0 wt−%, 5.8 wt−% and 20.8 wt−% Si) anodes and NMC622 cathodes with the same N/P ratio were built on pilot-scale. Calendar aging was studied at SoC 30%, 60%, and 100%, as well as temperature (25 °C, 45 °C, 60 °C) and time dependence. The aging data was analyzed in terms of capacity fade and a square-root behavior was observed. Differential voltage analysis (DVA) has been performed as a function of aging time. The observed temperature and time dependence is best described by time dependent, 3D Arrhenius plots. Post-Mortem analysis (SEM, EDX, GD-OES) is applied to investigate the changes on electrode and material level. Conclusions are drawn on the main aging mechanisms for calendar aging of Li-ion cells with Si/graphite anodes and differences between Si/graphite and pure graphite anodes are discussed. The Si-containing cells show a combination of lithium inventory loss and a loss of accessible Si active material, both caused by SEI growth.
- 1 January 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (1) , 010510
Open AccessAging Mechanism For Calendar Aging of Li-Ion Cells With Si/Graphite Anodes
Calendar aging of Li-ion batteries with Si/graphite electrodes was investigated within this study. A total of 121 single-layer pouch full cells with either graphite or Si/graphite (3.0 wt−%, 5.8 wt−% and 20.8 wt−% Si) anodes and NMC622 cathodes with the same N/P ratio were built on pilot-scale. Calendar aging was studied at SoC 30%, 60%, and 100%, as well as temperature (25 °C, 45 °C, 60 °C) and time dependence. The aging data was analyzed in terms of capacity fade and a square-root behavior was observed. Differential voltage analysis (DVA) has been performed as a function of aging time. The observed temperature and time dependence is best described by time dependent, 3D Arrhenius plots. Post-Mortem analysis (SEM, EDX, GD-OES) is applied to investigate the changes on electrode and material level. Conclusions are drawn on the main aging mechanisms for calendar aging of Li-ion cells with Si/graphite anodes and differences between Si/graphite and pure graphite anodes are discussed. The Si-containing cells show a combination of lithium inventory loss and a loss of accessible Si active material, both caused by SEI growth.
- Open Access
- 1 June 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (6) , 060536
Onset Shift of Li Plating on Si/Graphite Anodes with Increasing Si Content
Mixing graphite with Si particles in anodes of Li-ion batteries provides increased specific energy. In addition, higher Si contents lead to thinner anode coatings at constant areal capacity. In the present study, we systematically investigated the influence of the Si content on the susceptibility of Li plating on Si/graphite anodes. Si/graphite anodes with Si contents from 0 to 20.8 wt% combined with NMC622 cathodes were manufactured on pilot-scale. After initial characterization in coin half cells and by SEM, pouch full cells with fixed N/P ratios were built. Rate capability at different temperatures, and Post-Mortem analysis were carried out. Results from voltage relaxation, Li stripping, SEM measurements, glow discharge optical emission spectroscopy (GD-OES) depth profiling, and optical microscopy were validated against each other. A decreasing susceptibility to Li plating with increasing Si content in the anodes could be clearly observed. A critical C-rate was defined, at which Li plating was detected for the first time. It was also found that at 0 °C the critical C-rate increases with increasing Si contents. At 23 °C the SOC at which Li dendrites were first observed on the anode also increased with higher Si content.
- 1 June 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (6) , 060536
Open AccessOnset Shift of Li Plating on Si/Graphite Anodes with Increasing Si Content
Mixing graphite with Si particles in anodes of Li-ion batteries provides increased specific energy. In addition, higher Si contents lead to thinner anode coatings at constant areal capacity. In the present study, we systematically investigated the influence of the Si content on the susceptibility of Li plating on Si/graphite anodes. Si/graphite anodes with Si contents from 0 to 20.8 wt% combined with NMC622 cathodes were manufactured on pilot-scale. After initial characterization in coin half cells and by SEM, pouch full cells with fixed N/P ratios were built. Rate capability at different temperatures, and Post-Mortem analysis were carried out. Results from voltage relaxation, Li stripping, SEM measurements, glow discharge optical emission spectroscopy (GD-OES) depth profiling, and optical microscopy were validated against each other. A decreasing susceptibility to Li plating with increasing Si content in the anodes could be clearly observed. A critical C-rate was defined, at which Li plating was detected for the first time. It was also found that at 0 °C the critical C-rate increases with increasing Si contents. At 23 °C the SOC at which Li dendrites were first observed on the anode also increased with higher Si content.
- Open Access
- 1 May 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (5) , 050533
Detection of Li Deposition on Si/Graphite Anodes from Commercial Li-Ion Cells: A Post-Mortem GD-OES Depth Profiling Study
A new semi-quantitative method was developed to detect Li deposition on Si/graphite anodes. This method is based on Post-Mortem glow discharge optical emission spectroscopy (GD-OES) depth profiling. Based on the contents of Si, Li, and O in the GD-OES depth profiles, we define a corridor, in which the minimum amount of metallic Li on the anode is located. This method was applied to three types of commercial 18650 cells with Si/graphite anodes in the fresh state and with Li plating intentionally produced by cycling at low temperatures. Additional cells were cycling aged at 45 °C to 80% SOH. The main aging mechanisms at 45 °C were determined using differential voltage analysis (DVA), SEM, and half cell experiments. Subsequently, the cells aged at 45 °C were further cycled under the conditions that had led to Li deposition for the fresh cells. Furthermore, the anode coating thickness for 18 types of commercial Li-ion cells are correlated with the specific energy, while distinguishing between graphite anodes and Si/graphite anodes. Our extensive Post-Mortem study gives deep insights into the aging behavior of state-of-the-art Li-ion cells with Si/graphite anodes.
- 1 May 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (5) , 050533
Open AccessDetection of Li Deposition on Si/Graphite Anodes from Commercial Li-Ion Cells: A Post-Mortem GD-OES Depth Profiling Study
A new semi-quantitative method was developed to detect Li deposition on Si/graphite anodes. This method is based on Post-Mortem glow discharge optical emission spectroscopy (GD-OES) depth profiling. Based on the contents of Si, Li, and O in the GD-OES depth profiles, we define a corridor, in which the minimum amount of metallic Li on the anode is located. This method was applied to three types of commercial 18650 cells with Si/graphite anodes in the fresh state and with Li plating intentionally produced by cycling at low temperatures. Additional cells were cycling aged at 45 °C to 80% SOH. The main aging mechanisms at 45 °C were determined using differential voltage analysis (DVA), SEM, and half cell experiments. Subsequently, the cells aged at 45 °C were further cycled under the conditions that had led to Li deposition for the fresh cells. Furthermore, the anode coating thickness for 18 types of commercial Li-ion cells are correlated with the specific energy, while distinguishing between graphite anodes and Si/graphite anodes. Our extensive Post-Mortem study gives deep insights into the aging behavior of state-of-the-art Li-ion cells with Si/graphite anodes.