Kazuaki Sawada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kazuaki Sawada has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Toshihiko Noda
Toyohashi University of Technology
17 shared publications - Kazuhiro Takahashi
Toyohashi University of Technology
15 shared publications - Yong-Joon Choi
Toyohashi University of Technology
14 shared publications - Tomoya Ide
Toyohashi University of Technology
5 shared publications Makoto Ishida
Department of Electrical and Electronic Engineering, Toyohashi University of Technology , Toyohashi, Japan
4 shared publications- Daisuke Akai
Office for Technical Support Services, Toyohashi University of Technology, Toyohashi 441-8580, Japan
3 shared publications
Latest Publications
- Open Access
CMOS-Based Gas Direction Sensors with a Surface-Integrated Pillar
Conventional gas direction estimation methods that rely on concentration gradients or time-of-arrival differences typically require multiple spatially dispersed sensors, leading to increased system bulkiness and complexity. Furthermore, previous CMOS-based approaches that relied on gas diffusion struggled to achieve stable direction estimation in high-speed airflow environments. To address these challenges, we propose a streamlined method integrating a pillar onto a single CMOS gas-sensor array, eliminating additional MEMS fabrication. This approach exploits a fluid dynamic phenomenon where the pillar creates a distinct flow “shadow” pattern (a region of localized gas dilution) on the sensor surface. Experimental verification using ammonia gas confirmed that this “shadow” is clearly observable as a localized reduction in sensor output under high-speed turbulent flow. Crucially, the spatial position of this pattern correlates strongly with the direction of gas inflow. This study demonstrates the feasibility of gas direction estimation using a single chip, paving the way for high-precision detection in challenging, rapid-airflow environments.
Open AccessCMOS-Based Gas Direction Sensors with a Surface-Integrated Pillar
Conventional gas direction estimation methods that rely on concentration gradients or time-of-arrival differences typically require multiple spatially dispersed sensors, leading to increased system bulkiness and complexity. Furthermore, previous CMOS-based approaches that relied on gas diffusion struggled to achieve stable direction estimation in high-speed airflow environments. To address these challenges, we propose a streamlined method integrating a pillar onto a single CMOS gas-sensor array, eliminating additional MEMS fabrication. This approach exploits a fluid dynamic phenomenon where the pillar creates a distinct flow “shadow” pattern (a region of localized gas dilution) on the sensor surface. Experimental verification using ammonia gas confirmed that this “shadow” is clearly observable as a localized reduction in sensor output under high-speed turbulent flow. Crucially, the spatial position of this pattern correlates strongly with the direction of gas inflow. This study demonstrates the feasibility of gas direction estimation using a single chip, paving the way for high-precision detection in challenging, rapid-airflow environments.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02  (36) , 1724
(Invited) Filter-Free Wavelength Sensor for Multi-Analyte Fluorescence Detection in Biofield Applications
Wavelength and light intensity detection are critical in diverse analytical fields, including medical, environmental, chemical, biofield, and agricultural analyses. In biofield research, optical detection of wavelength information and light intensity variations, such as absorption, fluorescence, and spectral shift, is paramount for disease prediction, diagnosis, and analysis. Conventional methods employ filter cubes in fluorescence microscopes and monochromators for detecting cell information while offering high sensitivity and selectivity often present limitations due to their bulky size and high cost, thereby hindering their integration into portable point-of-care testing (POCT) devices. To address these challenges, significant research efforts have been directed toward developing high-performance, miniaturized systems leveraging semiconductor processes. On-chip photodetection devices, including fluorescence detection sensors integrating interference or absorption filters on CMOS image sensors, offer enhanced selectivity and sensitivity. However, detecting multi-wavelength changes associated with fluorescent reagents remains challenging due to the inherent integration of optical filters. Building upon these advancements in miniaturized photodetection, we reported the development of a filter-free wavelength sensor incorporating a photogate structure in our previous work [1, 2]. This sensor enables the simultaneous detection of both light intensity and wavelength without the necessity of optical filters, capitalizing on the intrinsic wavelength-dependent light absorption depth within silicon. The sensor was fabricated using a 1-polysilicon, 2-metal process at the LSI facility of the Toyohashi University of Technology, Japan. It features a three-layer architecture comprising deep n-well and p-well regions formed on a p-type silicon substrate. The application of a voltage to the photogate and n-well generates a potential peak (W) beneath the sensing area, effectively dividing the incident light-generated photocurrent into a surface component (Ifd) and a bottom component (Inw) based on the potential peak W. Wavelength identification is achieved through the analysis of the current ratio (Inw/Ifd). For biofield applications involving multi-peak light sources, the centroid wavelength is correlated with this current ratio, with experimental validation confirming a proportional relationship attributed to silicon's light absorption characteristics. Notably, the current ratio remains invariant to changes in light intensity, allowing for light intensity estimation by summing the individual current components. This paper introduces fluorescence detection methods utilizing our developed filter-free wavelength sensor. First, we demonstrate the sensor's capability for multiple fluorescence reagent detection by successfully identifying and quantifying different fluorescent dyes, showcasing its potential for multiplexed assays [2]. Building upon this, we present the results of multi-fluorescence sphere detection, where distinct fluorescently labeled microspheres were clearly distinguished based on their emission wavelengths, highlighting the sensor's spatial resolution and spectral discrimination abilities, with potential applications in microflow cytometry [3]. Finally, we successfully identified fluorescence emitted from multiple Legionella bacteria. By employing specific fluorescent labeling techniques targeting different strains or cellular components of Legionella, our filter-free wavelength image sensor enabled the simultaneous detection and differentiation of these bacteria, demonstrating its applicability in rapid and label-specific pathogen detection for biofield applications [4]. These diverse applications highlight the potential of the filter-free wavelength sensor as a versatile tool for various bioanalytical assays, underscoring its utility in biological and medical diagnostics, particularly in scenarios requiring cost-effective, portable, and multi-analyte detection capabilities. In the future, we will continue research to develop an optical sensor system that is more compact, sensitive, and selective and can be applied to various fields; furthermore, we will explore the potential of this sensor to detect other physical information beyond wavelength, such as temperature or hydrogen ion exponent, potentially broadening the sensor's utility in integrated microfluidic systems. [1] Multi-wavelength fluorescence detection of submicromolar concentrations using a filter-free fluorescence sensor, Sensors and Actuators B: Chemical, 256, pp.38-47 (2018) [2] Demonstrating a Filter-Free Wavelength Sensor with Double-Well Structure and Its Application, Biosensors , 12(11), p.1033 (2022) [3] Development of an on-chip microfluidic system with filter-free multiple-wavelength sensor for microflow cytometry, Sensors and Actuators B: Chemical, 350(1), p.130896 (2022) [4] Simultaneous visualization of multiple wavelengths by filter-free wavelength imaging system, Sensors and Actuators A: Physical, 365(1), p.114816 (2024)
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02  (36) , 1724
(Invited) Filter-Free Wavelength Sensor for Multi-Analyte Fluorescence Detection in Biofield Applications
Wavelength and light intensity detection are critical in diverse analytical fields, including medical, environmental, chemical, biofield, and agricultural analyses. In biofield research, optical detection of wavelength information and light intensity variations, such as absorption, fluorescence, and spectral shift, is paramount for disease prediction, diagnosis, and analysis. Conventional methods employ filter cubes in fluorescence microscopes and monochromators for detecting cell information while offering high sensitivity and selectivity often present limitations due to their bulky size and high cost, thereby hindering their integration into portable point-of-care testing (POCT) devices. To address these challenges, significant research efforts have been directed toward developing high-performance, miniaturized systems leveraging semiconductor processes. On-chip photodetection devices, including fluorescence detection sensors integrating interference or absorption filters on CMOS image sensors, offer enhanced selectivity and sensitivity. However, detecting multi-wavelength changes associated with fluorescent reagents remains challenging due to the inherent integration of optical filters. Building upon these advancements in miniaturized photodetection, we reported the development of a filter-free wavelength sensor incorporating a photogate structure in our previous work [1, 2]. This sensor enables the simultaneous detection of both light intensity and wavelength without the necessity of optical filters, capitalizing on the intrinsic wavelength-dependent light absorption depth within silicon. The sensor was fabricated using a 1-polysilicon, 2-metal process at the LSI facility of the Toyohashi University of Technology, Japan. It features a three-layer architecture comprising deep n-well and p-well regions formed on a p-type silicon substrate. The application of a voltage to the photogate and n-well generates a potential peak (W) beneath the sensing area, effectively dividing the incident light-generated photocurrent into a surface component (Ifd) and a bottom component (Inw) based on the potential peak W. Wavelength identification is achieved through the analysis of the current ratio (Inw/Ifd). For biofield applications involving multi-peak light sources, the centroid wavelength is correlated with this current ratio, with experimental validation confirming a proportional relationship attributed to silicon's light absorption characteristics. Notably, the current ratio remains invariant to changes in light intensity, allowing for light intensity estimation by summing the individual current components. This paper introduces fluorescence detection methods utilizing our developed filter-free wavelength sensor. First, we demonstrate the sensor's capability for multiple fluorescence reagent detection by successfully identifying and quantifying different fluorescent dyes, showcasing its potential for multiplexed assays [2]. Building upon this, we present the results of multi-fluorescence sphere detection, where distinct fluorescently labeled microspheres were clearly distinguished based on their emission wavelengths, highlighting the sensor's spatial resolution and spectral discrimination abilities, with potential applications in microflow cytometry [3]. Finally, we successfully identified fluorescence emitted from multiple Legionella bacteria. By employing specific fluorescent labeling techniques targeting different strains or cellular components of Legionella, our filter-free wavelength image sensor enabled the simultaneous detection and differentiation of these bacteria, demonstrating its applicability in rapid and label-specific pathogen detection for biofield applications [4]. These diverse applications highlight the potential of the filter-free wavelength sensor as a versatile tool for various bioanalytical assays, underscoring its utility in biological and medical diagnostics, particularly in scenarios requiring cost-effective, portable, and multi-analyte detection capabilities. In the future, we will continue research to develop an optical sensor system that is more compact, sensitive, and selective and can be applied to various fields; furthermore, we will explore the potential of this sensor to detect other physical information beyond wavelength, such as temperature or hydrogen ion exponent, potentially broadening the sensor's utility in integrated microfluidic systems. [1] Multi-wavelength fluorescence detection of submicromolar concentrations using a filter-free fluorescence sensor, Sensors and Actuators B: Chemical, 256, pp.38-47 (2018) [2] Demonstrating a Filter-Free Wavelength Sensor with Double-Well Structure and Its Application, Biosensors , 12(11), p.1033 (2022) [3] Development of an on-chip microfluidic system with filter-free multiple-wavelength sensor for microflow cytometry, Sensors and Actuators B: Chemical, 350(1), p.130896 (2022) [4] Simultaneous visualization of multiple wavelengths by filter-free wavelength imaging system, Sensors and Actuators A: Physical, 365(1), p.114816 (2024)
- Open Access
- 27 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117729
Development of a label-free Ca2+ image sensor to visualize extracellular Ca2+ dynamics in the biological samples
- 27 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117729
Open AccessDevelopment of a label-free Ca2+ image sensor to visualize extracellular Ca2+ dynamics in the biological samples
- Open Access
CMOS-Based Implantable Multi-Ion Image Sensor for Mg2+ Measurement in the Brain
An implantable multi-ion image sensor equipped with magnesium ion (Mg2+)-and calcium ion (Ca2+)-sensitive membranes was fabricated for the selective measurement of extracellular Mg2+ in the brain, and the sensor performance was evaluated. This sensor complements the low selectivity of the Mg2+-sensitive membrane for Ca2+ by depositing a Ca2+-sensitive membrane in addition to the Mg2+-sensitive membrane on a CMOS (Complementary Metal Oxide Semiconductor)-based potentiometric sensor array with 5.65 × 4.39 µm2 pitch, enabling selective measurement of Mg2+ and Ca2+. Characterization of the sensor confirmed a Ca2+ sensitivity of 26.5 mV/dec and Mg2+ sensitivity of 19 mV/dec. Based on validation experiments with varying concentrations of Mg2+ and Ca2+, selective Ca2+ and Mg2+ measurements were successfully achieved. Furthermore, real-time imaging of Mg2+ and Ca2+ and quantification of their concentration changes were performed. The developed sensor may be successfully applied for extracellular multi-ion imaging of Mg2+ and Ca2+ in the living brain.
Open AccessCMOS-Based Implantable Multi-Ion Image Sensor for Mg2+ Measurement in the Brain
An implantable multi-ion image sensor equipped with magnesium ion (Mg2+)-and calcium ion (Ca2+)-sensitive membranes was fabricated for the selective measurement of extracellular Mg2+ in the brain, and the sensor performance was evaluated. This sensor complements the low selectivity of the Mg2+-sensitive membrane for Ca2+ by depositing a Ca2+-sensitive membrane in addition to the Mg2+-sensitive membrane on a CMOS (Complementary Metal Oxide Semiconductor)-based potentiometric sensor array with 5.65 × 4.39 µm2 pitch, enabling selective measurement of Mg2+ and Ca2+. Characterization of the sensor confirmed a Ca2+ sensitivity of 26.5 mV/dec and Mg2+ sensitivity of 19 mV/dec. Based on validation experiments with varying concentrations of Mg2+ and Ca2+, selective Ca2+ and Mg2+ measurements were successfully achieved. Furthermore, real-time imaging of Mg2+ and Ca2+ and quantification of their concentration changes were performed. The developed sensor may be successfully applied for extracellular multi-ion imaging of Mg2+ and Ca2+ in the living brain.
- 8 January 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64  (1)
Machine learning-based wavelength detection system
This study proposes an AI-based filter-free wavelength sensor (FFS) system that identifies wavelengths using the absorption coefficient of silicon. Conventional systems rely on optical components, making them complex and difficult to miniaturize. Additionally, signals are prone to environmental and electrical interference. The proposed system, which consists of an analog circuit for signal conversion and a microcontroller with machine learning algorithms, processes signals and calculates wavelengths in real-time. It can detect central wavelengths in the 400–700 nm range with a 1.74% error rate, even with varying light intensities (0.20, 0.25, and 0.30 mW/cm²). This system enables accurate, real-time wavelength detection without optical components, overcoming challenges of traditional systems.
- 8 January 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64  (1)
Machine learning-based wavelength detection system
This study proposes an AI-based filter-free wavelength sensor (FFS) system that identifies wavelengths using the absorption coefficient of silicon. Conventional systems rely on optical components, making them complex and difficult to miniaturize. Additionally, signals are prone to environmental and electrical interference. The proposed system, which consists of an analog circuit for signal conversion and a microcontroller with machine learning algorithms, processes signals and calculates wavelengths in real-time. It can detect central wavelengths in the 400–700 nm range with a 1.74% error rate, even with varying light intensities (0.20, 0.25, and 0.30 mW/cm²). This system enables accurate, real-time wavelength detection without optical components, overcoming challenges of traditional systems.
- Open Access
Sensitivity Analysis of an Optical Interferometric Surface Stress Ethanol Gas Sensor with a Freestanding Nanosheet
Ethanol (EtOH) gas detection has garnered considerable attention owing to its wide range of applications in industries such as food, pharmaceuticals, medical diagnostics, and fuel management. The development of highly sensitive EtOH-gas sensors has become a focus of research. This study proposes an optical interferometric surface stress sensor for detecting EtOH gas. The sensor incorporates a 100 nm-thick freestanding membrane of Parylene C and gas-sensitive polymethylmethacrylate (PMMA) fabricated within a microcavity on a Si substrate. The results showed that reducing the thickness of the freestanding Parylene C membrane is essential for achieving higher sensitivity. Previously, a 100-nm-thick membrane transfer onto microcavities was achieved using a surfactant-assisted release technique. However, polymerization inhibition caused by the surfactant presented challenges in forming ultrathin membranes of several tens of nanometers. In this study, we employed a surfactant-free release technique using a hydrophilic natural oxide layer to successfully form a 14-nm-thick freestanding Parylene C membrane. In contrast, the optimum thickness of the gas-adsorbed PMMA membrane was approximately 295 nm. Moreover, we demonstrated that this thinner membrane improved EtOH gas detection sensitivity by a factor of eight compared with our previously reported sensor. Thus, this study advances the field of nanoscale materials and sensor technology.
Open AccessSensitivity Analysis of an Optical Interferometric Surface Stress Ethanol Gas Sensor with a Freestanding Nanosheet
Ethanol (EtOH) gas detection has garnered considerable attention owing to its wide range of applications in industries such as food, pharmaceuticals, medical diagnostics, and fuel management. The development of highly sensitive EtOH-gas sensors has become a focus of research. This study proposes an optical interferometric surface stress sensor for detecting EtOH gas. The sensor incorporates a 100 nm-thick freestanding membrane of Parylene C and gas-sensitive polymethylmethacrylate (PMMA) fabricated within a microcavity on a Si substrate. The results showed that reducing the thickness of the freestanding Parylene C membrane is essential for achieving higher sensitivity. Previously, a 100-nm-thick membrane transfer onto microcavities was achieved using a surfactant-assisted release technique. However, polymerization inhibition caused by the surfactant presented challenges in forming ultrathin membranes of several tens of nanometers. In this study, we employed a surfactant-free release technique using a hydrophilic natural oxide layer to successfully form a 14-nm-thick freestanding Parylene C membrane. In contrast, the optimum thickness of the gas-adsorbed PMMA membrane was approximately 295 nm. Moreover, we demonstrated that this thinner membrane improved EtOH gas detection sensitivity by a factor of eight compared with our previously reported sensor. Thus, this study advances the field of nanoscale materials and sensor technology.
- Open Access
- 9 May 2024
- Published by MDPI AG in Electronics
- Vol. 13  (10) , 1847
Detecting Smell/Gas-Source Direction Using Output Voltage Characteristics of a CMOS Smell Sensor
Various organisms, such as dogs and moths, can locate their prey and mates by sensing their smells. Following this manner, if an engineering device with the capability to detect a smell or gas source is realized, it can have a wide range of potential applications, such as searching for landmines, locating gas leaks, and rapid detection of fire. A previous study on the estimation of smell and gas-flow direction successfully detected the smell/gas-source direction in low-wind-velocity environments using a semiconductor gas sensor array. However, some problems are generally associated with the use of semiconductor gas sensors due to the use of heaters. This study aimed to detect the location of a smell/gas source using an integrated CMOS smell sensor array, which operates at room temperature without a heater. The experiment showed that under ideal conditions, the order of gas responses and concentration gradient of the gas enabled the estimation of the direction of the smell/gas-source location on one side of the sensor.
- 9 May 2024
- Published by MDPI AG in Electronics
- Vol. 13  (10) , 1847
Open AccessDetecting Smell/Gas-Source Direction Using Output Voltage Characteristics of a CMOS Smell Sensor
Various organisms, such as dogs and moths, can locate their prey and mates by sensing their smells. Following this manner, if an engineering device with the capability to detect a smell or gas source is realized, it can have a wide range of potential applications, such as searching for landmines, locating gas leaks, and rapid detection of fire. A previous study on the estimation of smell and gas-flow direction successfully detected the smell/gas-source direction in low-wind-velocity environments using a semiconductor gas sensor array. However, some problems are generally associated with the use of semiconductor gas sensors due to the use of heaters. This study aimed to detect the location of a smell/gas source using an integrated CMOS smell sensor array, which operates at room temperature without a heater. The experiment showed that under ideal conditions, the order of gas responses and concentration gradient of the gas enabled the estimation of the direction of the smell/gas-source location on one side of the sensor.
- 1 April 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63  (4) , 04SP43
Wireless wavelength measurement system with temperature compensation using filter-free wavelength sensors
Portable wavelength detection systems have been developed for various environmental and biochemical applications. Conventional systems have some limitations as they are unable to adapt to changes in wavelength and rely on optical filters or slits to distinguish between different wavelengths. To address these limitations, a filter-free wavelength sensor system was proposed, utilizing the absorption coefficient of silicon to identify wavelengths. The proposed system comprises an analog circuit for measuring photocurrent from a filter-free wavelength sensor, integrated with a temperature sensor and microcontroller for signal processing. The proposed system can measure currents with a resolution of 1.2 pA within a 30 nA range, achieving a coefficient of determination of 0.999 for measured currents in relation to light intensity. The microcontroller features a temperature compensation algorithm, enabling wireless control and data transmission. Applying temperature compensation reduced the rate of errors in the data by 61%. By eliminating the need for optical components, a wireless measurement system was developed that can accurately identify wavelengths.
- 1 April 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63  (4) , 04SP43
Wireless wavelength measurement system with temperature compensation using filter-free wavelength sensors
Portable wavelength detection systems have been developed for various environmental and biochemical applications. Conventional systems have some limitations as they are unable to adapt to changes in wavelength and rely on optical filters or slits to distinguish between different wavelengths. To address these limitations, a filter-free wavelength sensor system was proposed, utilizing the absorption coefficient of silicon to identify wavelengths. The proposed system comprises an analog circuit for measuring photocurrent from a filter-free wavelength sensor, integrated with a temperature sensor and microcontroller for signal processing. The proposed system can measure currents with a resolution of 1.2 pA within a 30 nA range, achieving a coefficient of determination of 0.999 for measured currents in relation to light intensity. The microcontroller features a temperature compensation algorithm, enabling wireless control and data transmission. Applying temperature compensation reduced the rate of errors in the data by 61%. By eliminating the need for optical components, a wireless measurement system was developed that can accurately identify wavelengths.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02  (30) , 1544
(Invited) Detection of Wavelength Information by Filter-Free Wavelength Sensor and Its Applications
This paper introduces the wavelength and light intensity detection method using the filter-free wavelength sensor without optical filters. Optical detection methods are widely used in medical, environmental, chemical, biofield, and agricultural analyses. In the biofield, the optical detection method makes it possible to predict, diagnose, and analyze diseases by detecting the wavelength information and light intensity, such as absorption, fluorescence, and spectral shift. In order to measure a specific wavelength and intensity of light, mainly used a detection method such as a filter cube of a fluorescence microscope or a monochromator of a spectrometer system. Even if this system has high sensitivity and selectivity, it is not easy to apply to POCTs that require portability due to the high price and increased system volume due to the integration of optical filters and other parts. Therefore, various studies have reported using semiconductor processes to detect the wavelength and light intensity with a high-performance and miniaturized system. An on-chip photodetection device has been reported, such as a fluorescence detection sensor to integrate interference or absorption filters on CMOS image sensors with high selectivity and sensitivity. Since the specific wavelength of light intensity detection is possible, it can apply to biofields such as fluorescence analysis. However, detecting different wavelength changes by fluorescent reagent is difficult because the optical filter is integrated into the CMOS image sensor. A method of multi-wavelength analysis with the single-pixel without an optical filter is reported using a CMOS-buried quad p-n junction photodetector. Since the light wavelength has a different absorption depth depending on the silicon absorption coefficient, it is possible to separate wavelength by measuring the current generated at each p-n junction. Therefore, it will provide a high-space-resolution image in the biofield. However, the possibility detection wavelength band is fixed according to the buried p-n junction numbers and depth. Previously, we reported a filter-free wavelength sensor with a photogate structure. Sensor can detect light intensity and wavelength without optical filters based on the dependence of the light absorption depth in silicon. The sensor fabricates using the 1-polysilicon, 2-metal process in the LSI facility of the Toyohashi University of Technology in Japan, as shown in Fig1(a). The sensor consists of a three-layer structure where deep n-well and p-well were formed on a p-type silicon substrate, as shown in Fig1(b). Applying a voltage to the photogate and n-well forms a potential peak W as a mountain shape below the sensing area. Therefore, the photocurrent generated by the incident light was divided into the surface side (I PG), and bottom side (I n-well) based on the potential peak W and wavelength identification is possible from the current ratio (I n-well/I PG). To detect the wavelength information of multi-peak light for applications in the biofield, compare the centroid wavelength and current ratio. We experimentally confirmed that the centroid wavelength was proportional to the current ratio by the light absorption depth of silicon. Since the light absorption depth depends on the light wavelength, the current ratio is constant even when the light intensity changes. Therefore, estimation of the light intensity is possible by the sum of each current. We proposed a wavelength, spectral shift, and absorbance measure method using a filter-free wavelength sensor to apply various fields. Figure 2(a) shows a schematic for detecting the fluorescence wavelength. Without using optical filters, fluorescence can be quantified by calculating the centroid wavelength of the light even when the excitation light is emitted simultaneously. In addition, it successfully identified fluorescence emitted from Legionella bacteria [1]. Figure 2(b) shows a schematic diagram that can identify the change in the spectrum using a sensor. Integrating an LSPR biosensor into a filter-free wavelength sensor makes it possible to measure the amount of spectrum changed by molecular binding. Therefore, miniaturization of the LSPR detection system becomes possible, and we succeeded in detecting and quantifying the S-protein of SARS-CoV-2 [2]. Figure 2(c) shows a schematic diagram of the absorbance measurements method for samples that absorb a specific wavelength range. By the proposed absorbance measurement method was possible to measure the ratio of chlorophyll content and chlorophyll a/b ratio contributing to plant photosynthesis [3]. The filter-free wavelength sensor fabricated by the semiconductor process has been confirmed for its application as an optical detection system. In the future, we will continue research to develop an optical sensor system that is more compact, sensitive, and selective and can be applied to various fields. [1] Biosensors, vol.12, no.11, p.1033 (2022) [2] Applied Physics Express, vol.16, no.1, p.012012 (2023) [3] Jpn. J. Appl. Phys., vol.61, p.SD1041 (2022) Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02  (30) , 1544
(Invited) Detection of Wavelength Information by Filter-Free Wavelength Sensor and Its Applications
This paper introduces the wavelength and light intensity detection method using the filter-free wavelength sensor without optical filters. Optical detection methods are widely used in medical, environmental, chemical, biofield, and agricultural analyses. In the biofield, the optical detection method makes it possible to predict, diagnose, and analyze diseases by detecting the wavelength information and light intensity, such as absorption, fluorescence, and spectral shift. In order to measure a specific wavelength and intensity of light, mainly used a detection method such as a filter cube of a fluorescence microscope or a monochromator of a spectrometer system. Even if this system has high sensitivity and selectivity, it is not easy to apply to POCTs that require portability due to the high price and increased system volume due to the integration of optical filters and other parts. Therefore, various studies have reported using semiconductor processes to detect the wavelength and light intensity with a high-performance and miniaturized system. An on-chip photodetection device has been reported, such as a fluorescence detection sensor to integrate interference or absorption filters on CMOS image sensors with high selectivity and sensitivity. Since the specific wavelength of light intensity detection is possible, it can apply to biofields such as fluorescence analysis. However, detecting different wavelength changes by fluorescent reagent is difficult because the optical filter is integrated into the CMOS image sensor. A method of multi-wavelength analysis with the single-pixel without an optical filter is reported using a CMOS-buried quad p-n junction photodetector. Since the light wavelength has a different absorption depth depending on the silicon absorption coefficient, it is possible to separate wavelength by measuring the current generated at each p-n junction. Therefore, it will provide a high-space-resolution image in the biofield. However, the possibility detection wavelength band is fixed according to the buried p-n junction numbers and depth. Previously, we reported a filter-free wavelength sensor with a photogate structure. Sensor can detect light intensity and wavelength without optical filters based on the dependence of the light absorption depth in silicon. The sensor fabricates using the 1-polysilicon, 2-metal process in the LSI facility of the Toyohashi University of Technology in Japan, as shown in Fig1(a). The sensor consists of a three-layer structure where deep n-well and p-well were formed on a p-type silicon substrate, as shown in Fig1(b). Applying a voltage to the photogate and n-well forms a potential peak W as a mountain shape below the sensing area. Therefore, the photocurrent generated by the incident light was divided into the surface side (I PG), and bottom side (I n-well) based on the potential peak W and wavelength identification is possible from the current ratio (I n-well/I PG). To detect the wavelength information of multi-peak light for applications in the biofield, compare the centroid wavelength and current ratio. We experimentally confirmed that the centroid wavelength was proportional to the current ratio by the light absorption depth of silicon. Since the light absorption depth depends on the light wavelength, the current ratio is constant even when the light intensity changes. Therefore, estimation of the light intensity is possible by the sum of each current. We proposed a wavelength, spectral shift, and absorbance measure method using a filter-free wavelength sensor to apply various fields. Figure 2(a) shows a schematic for detecting the fluorescence wavelength. Without using optical filters, fluorescence can be quantified by calculating the centroid wavelength of the light even when the excitation light is emitted simultaneously. In addition, it successfully identified fluorescence emitted from Legionella bacteria [1]. Figure 2(b) shows a schematic diagram that can identify the change in the spectrum using a sensor. Integrating an LSPR biosensor into a filter-free wavelength sensor makes it possible to measure the amount of spectrum changed by molecular binding. Therefore, miniaturization of the LSPR detection system becomes possible, and we succeeded in detecting and quantifying the S-protein of SARS-CoV-2 [2]. Figure 2(c) shows a schematic diagram of the absorbance measurements method for samples that absorb a specific wavelength range. By the proposed absorbance measurement method was possible to measure the ratio of chlorophyll content and chlorophyll a/b ratio contributing to plant photosynthesis [3]. The filter-free wavelength sensor fabricated by the semiconductor process has been confirmed for its application as an optical detection system. In the future, we will continue research to develop an optical sensor system that is more compact, sensitive, and selective and can be applied to various fields. [1] Biosensors, vol.12, no.11, p.1033 (2022) [2] Applied Physics Express, vol.16, no.1, p.012012 (2023) [3] Jpn. J. Appl. Phys., vol.61, p.SD1041 (2022) Figure 1
- 29 September 2023
- Published by The Electrochemical Society in ECS Transactions
- Vol. 112  (1) , 139-146
(Invited) Detection of Wavelength Information by Filter-Free Wavelength Sensor and Its Applications
This paper introduces the wavelength and light intensity detection method using the filter-free wavelength sensor without optical components. Using a modified CMOS process, we developed a filter-free wavelength sensor with a photogate structure. The sensor can detect light intensity and wavelength without optical filters based on the dependence of the light absorption depth in silicon. Using a developed sensor, we demonstrated a wavelength, spectral shift, and light absorption detection method to apply various fields. In the future, we will continue research to realize an optical sensor system that is more compact, sensitive, and selective.
- 29 September 2023
- Published by The Electrochemical Society in ECS Transactions
- Vol. 112  (1) , 139-146
(Invited) Detection of Wavelength Information by Filter-Free Wavelength Sensor and Its Applications
This paper introduces the wavelength and light intensity detection method using the filter-free wavelength sensor without optical components. Using a modified CMOS process, we developed a filter-free wavelength sensor with a photogate structure. The sensor can detect light intensity and wavelength without optical filters based on the dependence of the light absorption depth in silicon. Using a developed sensor, we demonstrated a wavelength, spectral shift, and light absorption detection method to apply various fields. In the future, we will continue research to realize an optical sensor system that is more compact, sensitive, and selective.