JDJames C. Dreese

James C. Dreese

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James C. Dreese has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A single lateral hinge screw increased resistance to varus stress after medial closing wedge distal femoral osteotomy in a Sawbones model: A biomechanical analysis

    by Benjamin J. Main, Matthieu Ollivier, Pooyan Abbasi, Steven J. Svoboda, James C. Dreese, Jingyi Shao, Wiemi A. Douoguih

    Purpose: To determine the biomechanical effects of a lateral hinge screw on postoperative fracture after medial closing wedge distal femoral osteotomy (MCWDFO). It was hypothesized that adding a lateral hinge screw would significantly increase the failure strength of the hinge. Methods: Twelve Sawbone femurs were used for the study. A biplanar cut was made, a protective lateral hinge pin was placed, and a 5 mm‐closing wedge osteotomy was performed in each specimen. After osteotomy, the hinge pin was removed in six specimens, and in the remaining six specimens, the hinge pin was replaced with a lateral hinge screw. A varus load was then applied utilizing a load frame in a single load‐to‐failure test. Failure was defined as the point just before a substantial drop in the force versus displacement curve. Nonparametric Wilcoxon rank‐sum test was performed to compare maximum load and stiffness between the hinge screw and no hinge screw groups with p < 0.05 considered the threshold of statistical significance. Results: The maximum load to failure was significantly higher in the hinge screw group versus the control group, 440 ± 70 N versus 256 ± 107 N (mean ± standard deviation), respectively. Load to failure was 72% higher in the hinge screw group versus the no hinge screw group. No significant difference in stiffness was found between the groups. Conclusion: Using a Sawbone model, the current data showed that placement of a lateral hinge screw significantly increased resistance to varus stress following MCWDFO compared with a construct having no screw. Additionally, no significant difference in stiffness was observed between the group with the hinge screw and the group without the screw. Further investigation should assess the clinical benefit of a hinge screw in reducing surgical morbidity during the postoperative period for patients undergoing a distal femoral osteotomy. Level of Evidence: N/A.


  • Open Access

    Poster 224: Complications Associated with Proximal Hamstring Tendon Repair: A Systematic Review

    by Eliza Abraham, Casey Imbergamo, Sean Sequeira, James Dreese, Heath Gould, Jonathan Lawson

    Objectives: Proximal hamstring tendon ruptures typically occur as a result of simultaneous hip flexion and knee extension, leading to avulsion of the conjoint and/or semimembranosus tendons from their origin at the ischial tuberosity. Surgical repair of proximal hamstring tendon ruptures has been shown in multiple clinical outcome studies to be superior to nonoperative management, with improved functional scores and ability to return to sport postoperatively. Although several potential complications have been reported in the literature, few studies have comprehensively analyzed the complication profile of proximal hamstring tendon repair. The purpose of this systematic review was to identify the overall rate of complications following proximal hamstring tendon repair, to differentiate these complications into categories, and to compare the complication rates of open versus endoscopic repair. Methods: A systematic review of original research articles was performed using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. To qualify for study inclusion, included articles were required to be published in English, Level 4 evidence or higher, and had to examine surgical repair of proximal hamstring tendon ruptures. No restrictions were made regarding publication date and methodological quality. Data regarding complications were extracted to calculate the overall complication rate as well as the rate of major and minor complications. A quantitative data synthesis was conducted using Chi-square tests to compare the proportion of patients who experienced complications with endoscopic and open approaches. Results: Forty-three articles including 2,823 proximal hamstring tendon repairs were identified. The overall postoperative complication rate was 15.4% (n = 436). The rate of major complications was 4.6%, including a 0.8% re-rupture rate, 0.8% re-operation rate, 1.7% rate of sciatic nerve injury, 0.9% rate of venous thromboembolism (VTE), and 0.4% rate of deep infection. Minor complications included posterior femoral cutaneous nerve injury (2.4%), persistent sitting pain (2.3%), persistent hamstring myopathy (2.3%), hematoma/seroma (0.8%), peri-incisional numbness (1.8%), and superficial infection (1.1%). Endoscopic proximal hamstring tendon repair was associated with a higher rate of overall complications (p = 0.012), major complications (p = 0.048), and minor complications (p < 0.001) compared to open repair. Conclusions: Proximal hamstring tendon repair is associated with an overall complication rate of 15.4%, including a 4.6% rate of major complications. There was a statistically significant increase in complications for patients treated endoscopically compared to those who underwent an open surgical repair.