Bharat Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bharat Singh has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ashwani Kumar
NIT Kurukshetra
7 shared publications - Nitin Kumar Saxena
University of Denver
2 shared publications Ashwani Kumar
1 shared publicationAshwani Kumar Sharma
National Institute of Technology Kurukshetra
1 shared publication- Atma Ram Gupta
Department of Electrical Engineering, Government Engineering College Kaimur, Bihar Engineering University, Department of Science Technology and Technical Education, Patna, India
1 shared publication - David Wenzhong Gao
Department of Electrical and Computer Engineering, University of Denver, Denver, CO, USA
1 shared publication
Latest Publications
- 2 January 2025
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 26 (5) , 879-903
Optimal allocation of hybrid renewable energy sources using progressive L-index method for voltage stability margin enhancement and impact of storage devices
Distribution system networks (DSN) are presently gaining more concern in terms of security and stability due to the penetration of distributed energy resources (DERs) and the integration of microgrids. The active DSNs may have their operating point near the maximum power transfer capability due to the optimal asset utilization, which jeopardizes the stability of the network. The article presents a novel approach for optimizing the placement of solar PV, D-STATCOMs and energy storage in distribution networks. The method minimizes the L-Index for voltage stability, reduces voltage deviations, and lowers annual operating costs, ensuring enhanced performance and cost-efficiency for modern power systems. The article presents a novel approach of progressive L-Index to determine the suitable sites for optimal location of the DERs using Particle Swarm Optimization (PSO). It also utilizes the mixed-integer nonlinear programming using GAMS to compute the appropriate size of DERs, D-STATCOM and the energy storage. The studies have been performed on the standard IEEE-69 bus test DSN. The results exhibit that the proposed scheme enhances the overall voltage profile of the DSN, and the VSM is upgraded by 41.60 % with DER installation, as compared without DG.
- 2 January 2025
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 26 (5) , 879-903
Optimal allocation of hybrid renewable energy sources using progressive L-index method for voltage stability margin enhancement and impact of storage devices
Distribution system networks (DSN) are presently gaining more concern in terms of security and stability due to the penetration of distributed energy resources (DERs) and the integration of microgrids. The active DSNs may have their operating point near the maximum power transfer capability due to the optimal asset utilization, which jeopardizes the stability of the network. The article presents a novel approach for optimizing the placement of solar PV, D-STATCOMs and energy storage in distribution networks. The method minimizes the L-Index for voltage stability, reduces voltage deviations, and lowers annual operating costs, ensuring enhanced performance and cost-efficiency for modern power systems. The article presents a novel approach of progressive L-Index to determine the suitable sites for optimal location of the DERs using Particle Swarm Optimization (PSO). It also utilizes the mixed-integer nonlinear programming using GAMS to compute the appropriate size of DERs, D-STATCOM and the energy storage. The studies have been performed on the standard IEEE-69 bus test DSN. The results exhibit that the proposed scheme enhances the overall voltage profile of the DSN, and the VSM is upgraded by 41.60 % with DER installation, as compared without DG.
- 24 February 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (4) , 5133-5152
Techno-economic feasibility analysis with energy storage and demand response program for the smart home energy management
- 24 February 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (4) , 5133-5152
Techno-economic feasibility analysis with energy storage and demand response program for the smart home energy management
- 12 January 2024
- Published by Springer Nature
- p. 2-14
Optimal Energy Scheduling and Feasibility Analysis in Microgrid Considering the Hospital Load Model with Isolated Grid
- 12 January 2024
- Published by Springer Nature
- p. 2-14
Optimal Energy Scheduling and Feasibility Analysis in Microgrid Considering the Hospital Load Model with Isolated Grid
- 13 November 2022
- Published by Taylor & Francis in Smart Science
- Vol. 11 (2) , 334-354
Impact of D-STATCOM and OLTC with Integrated Volt/var Control in Distribution System for Power Loss Minimization and Voltage Control
Voltage control and power loss minimization are some of the crucial issues in distribution system energy management. Finding the best strategy for Voltage control and power loss reduction is a critical task for the distribution network operator (DNO). The main contributions of the proposed work are (i) determination of size and location of the Distribution Static Synchronous Compensator (DSTATCOM) with (OLTC). (ii) to minimize the power loss and Voltage deviation with the Volt/var control strategy. (iii) To obtain the impact of single and multiple D-STATCOM units with and without OLTC. The proposed method is tested on two test systems: (i) IEEE-69 RDS and (ii) IEEE-25 bus three-phase unbalanced system. The benefits of the proposed results are addressed in the reduction of power loss, enhancement of the Voltage profile, and the annual cost of saving for the DNO. The results are tabulated, verified, and compared with other methods. The power loss is reduced to 39.25%, 38.04% for 69 bus and 25 bus test systems. The minimum Voltage profile is enhanced from 0.90918 pu to 0.9619 pu for 69 bus RDS and from 0.922559 pu to 0.9747 pu for 25 bus three-phase system.
- 13 November 2022
- Published by Taylor & Francis in Smart Science
- Vol. 11 (2) , 334-354
Impact of D-STATCOM and OLTC with Integrated Volt/var Control in Distribution System for Power Loss Minimization and Voltage Control
Voltage control and power loss minimization are some of the crucial issues in distribution system energy management. Finding the best strategy for Voltage control and power loss reduction is a critical task for the distribution network operator (DNO). The main contributions of the proposed work are (i) determination of size and location of the Distribution Static Synchronous Compensator (DSTATCOM) with (OLTC). (ii) to minimize the power loss and Voltage deviation with the Volt/var control strategy. (iii) To obtain the impact of single and multiple D-STATCOM units with and without OLTC. The proposed method is tested on two test systems: (i) IEEE-69 RDS and (ii) IEEE-25 bus three-phase unbalanced system. The benefits of the proposed results are addressed in the reduction of power loss, enhancement of the Voltage profile, and the annual cost of saving for the DNO. The results are tabulated, verified, and compared with other methods. The power loss is reduced to 39.25%, 38.04% for 69 bus and 25 bus test systems. The minimum Voltage profile is enhanced from 0.90918 pu to 0.9619 pu for 69 bus RDS and from 0.922559 pu to 0.9747 pu for 25 bus three-phase system.
- 28 May 2022
- Published by Taylor & Francis in Smart Science
- Vol. 11 (2) , 251-275
Impact of Electric Vehicle Load Demand and Energy Storage Device in Integrated Renewable Energy Sources
The intermittent nature of renewable-based generation may cause the dip or rise generation and load imbalances. Besides, the higher penetration of Electric Vehicles can affect the voltage profile and imbalances. The main contribution of the proposed work is to determine (i) the realistic load model of electric vehicle (EV) charging station (ii) the size of battery energy storage (BES) considering the EV load demand with the most realistic ZIP load. (iii) the cost-benefit analysis and the probabilistic modeling of EV load demand are considered for BES sizing. (iv) minimization of the daily energy loss (v), maximizing the total benefit of the system, (vi) the nature of the electric vehicle load demand has been modeled for size determination of energy storage devices. The fuel cost of the thermal generator has been minimized, and the operating and maintenance cost of the Solar Photovoltaic (PV), and Wind Turbine (WT) have been considered in the objective function. The daily energy loss has been reduced to 30.085%. The voltage deviation has been reduced to 1.165%. The analysis has been carried out for the IEEE-33 bus test system. The iterative Monte Carlo Simulation and Nonlinear Programming have been used to solve the multi-objective problem.
- 28 May 2022
- Published by Taylor & Francis in Smart Science
- Vol. 11 (2) , 251-275
Impact of Electric Vehicle Load Demand and Energy Storage Device in Integrated Renewable Energy Sources
The intermittent nature of renewable-based generation may cause the dip or rise generation and load imbalances. Besides, the higher penetration of Electric Vehicles can affect the voltage profile and imbalances. The main contribution of the proposed work is to determine (i) the realistic load model of electric vehicle (EV) charging station (ii) the size of battery energy storage (BES) considering the EV load demand with the most realistic ZIP load. (iii) the cost-benefit analysis and the probabilistic modeling of EV load demand are considered for BES sizing. (iv) minimization of the daily energy loss (v), maximizing the total benefit of the system, (vi) the nature of the electric vehicle load demand has been modeled for size determination of energy storage devices. The fuel cost of the thermal generator has been minimized, and the operating and maintenance cost of the Solar Photovoltaic (PV), and Wind Turbine (WT) have been considered in the objective function. The daily energy loss has been reduced to 30.085%. The voltage deviation has been reduced to 1.165%. The analysis has been carried out for the IEEE-33 bus test system. The iterative Monte Carlo Simulation and Nonlinear Programming have been used to solve the multi-objective problem.
- 5 November 2020
- Published by Springer Nature
- p. 317-325
Optimal Placement of DG with Battery Energy Storage Using CPLS and Combined Dispatch Strategy
- 5 November 2020
- Published by Springer Nature
- p. 317-325
Optimal Placement of DG with Battery Energy Storage Using CPLS and Combined Dispatch Strategy