Ryan Hepple
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ryan Hepple has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Siliang Yang
Mott MacDonald, Leeds LS12 1BE, UK
2 shared publications - Deo Prasad
School of Built Environment, University of New South Wales, Sydney, NSW 2052, Australia
1 shared publication - Qian Zhang
Department of Engineering, Durham University, Durham DH1 3LE, UK
1 shared publication - Rebecca Jing Yang
School of Property Construction and Project Management, RMIT University, Melbourne, VIC 3000, Australia
1 shared publication - Sanober Khattak
Institute for Sustainable Futures, De Montfort University, Leicester LE1 9BH, UK
1 shared publication - Yusen Zhao
School of Property Construction and Project Management, RMIT University, Melbourne, VIC 3000, Australia
1 shared publication
Latest Publications
- Open Access
Investigating the Effects of PCM-Integrated Walls on Thermal Performance for UK Residential Buildings of Different Typologies
Phase change materials (PCMs) can improve the thermal performance of building facades. The integration position of a PCM in the facades is influenced by multiple factors including the material properties of the PCM, building types, and the internal and external conditions of a building. However, this has not been a focus within the UK dwelling stock, where many dwellings are not thermally protected. This paper, therefore, presents a numerical study with the aid of building simulation that comparatively analysed the thermal performance between four typical UK dwelling types (semi-detached house, terraced house, detached house, and apartment) situated in North East England. The PCM was implemented into the external wall of the dwellings with the positions altered to determine the most effective position. It was determined that the PCM positioned internally was the most effective for all the dwelling types. These results demonstrated that the PCM being implemented in the apartment, semi-detached, and terraced houses had only marginal heat loss reductions (by 8%, 14%, and 8%, respectively) in comparison with that of the detached house (by 30%). It was also found that the large external wall area of the detached house acted as significant thermal energy storage, which was capable of offsetting heat transmission and stabilising indoor thermal conditions. In summary, this paper contributes to the matters concerning the effect of PCMs on indoor thermal performance in dwellings of different typologies in the UK.
Open AccessInvestigating the Effects of PCM-Integrated Walls on Thermal Performance for UK Residential Buildings of Different Typologies
Phase change materials (PCMs) can improve the thermal performance of building facades. The integration position of a PCM in the facades is influenced by multiple factors including the material properties of the PCM, building types, and the internal and external conditions of a building. However, this has not been a focus within the UK dwelling stock, where many dwellings are not thermally protected. This paper, therefore, presents a numerical study with the aid of building simulation that comparatively analysed the thermal performance between four typical UK dwelling types (semi-detached house, terraced house, detached house, and apartment) situated in North East England. The PCM was implemented into the external wall of the dwellings with the positions altered to determine the most effective position. It was determined that the PCM positioned internally was the most effective for all the dwelling types. These results demonstrated that the PCM being implemented in the apartment, semi-detached, and terraced houses had only marginal heat loss reductions (by 8%, 14%, and 8%, respectively) in comparison with that of the detached house (by 30%). It was also found that the large external wall area of the detached house acted as significant thermal energy storage, which was capable of offsetting heat transmission and stabilising indoor thermal conditions. In summary, this paper contributes to the matters concerning the effect of PCMs on indoor thermal performance in dwellings of different typologies in the UK.
- Open Access
Comparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Due to the impacts of carbon emissions on climate change and the expected dramatic increase in global cooling demand by 2050, it is of a paramount importance that the required energy to cool buildings is accurately predicted. This ensures that equipment is appropriately sized, which ultimately reduces energy consumption and global carbon emissions. CIBSE and ASHRAE standards are both widely adopted for cooling load predictions, but they adopt different calculation methods, with CIBSE adopting admittance and ASHRAE adopting radiant time series (RTS), which produce significantly different results in cooling load. This study comparatively and qualitatively evaluates the CIBSE admittance and ASHRAE RTS cooling load models by analysing their structures and key input parameters for a mock-up building to identify inconsistencies between the two methods. There were flaws within both models that resulted in the CIBSE method underpredicting the cooling load, whereas the ASHRAE method typically overpredicting it. This resulted in a maximal average difference of over 60%. The substantial predicted cooling load difference was mainly caused by the ASHRAE RTS model, which was highly receptive to solar gains, and it consequently led to overprediction in cooling load when compared to the CIBSE admittance model.
Open AccessComparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Due to the impacts of carbon emissions on climate change and the expected dramatic increase in global cooling demand by 2050, it is of a paramount importance that the required energy to cool buildings is accurately predicted. This ensures that equipment is appropriately sized, which ultimately reduces energy consumption and global carbon emissions. CIBSE and ASHRAE standards are both widely adopted for cooling load predictions, but they adopt different calculation methods, with CIBSE adopting admittance and ASHRAE adopting radiant time series (RTS), which produce significantly different results in cooling load. This study comparatively and qualitatively evaluates the CIBSE admittance and ASHRAE RTS cooling load models by analysing their structures and key input parameters for a mock-up building to identify inconsistencies between the two methods. There were flaws within both models that resulted in the CIBSE method underpredicting the cooling load, whereas the ASHRAE method typically overpredicting it. This resulted in a maximal average difference of over 60%. The substantial predicted cooling load difference was mainly caused by the ASHRAE RTS model, which was highly receptive to solar gains, and it consequently led to overprediction in cooling load when compared to the CIBSE admittance model.