Appala Naidu Karanam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Appala Naidu Karanam has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Binod Shaw
National Institute of Technology Raipur Department of Electrical Engineering
4 shared publicationsD. V. N. Ananth
K L Educational Society
1 shared publication- Dasika Nagesh Kumar
Department of Civil Engineering, Indian Institute of Science, Bengaluru, India
1 shared publication - Deepak Chowdary Duvvada
Vignan's Institute of Information Technology, Andhra Pradesh, INDIA
1 shared publication J. Kotturu
Dept. of Electrical Engineering, IIT Roorkee, India
1 shared publicationJyoti Ranjan Nayak
Vignan's Institute of Information Technology Department of Electrical and Electronics Engineering
1 shared publication
Latest Publications
- Open Access
- 2 December 2022
- Published by Wiley
Implementation of Crow Search Algorithm based two degree of freedom combined fractional order PID controller for AGC of hydro-thermal power system with wind and small hydro power plants
The unceasing efforts to design an optimal controller for automatic generation control (AGC) in power systems motivate the design of a novel Two-Degree-of-Freedom-Combined Fractional Order PID (2-DOF-Combined FOPID) controller. Two-area interconnected power systems comprised of reheated thermal and hydro units with boiler dynamics, generator rate constraints and dead zone non-linearity in each area are tested using the designed controller. The performance of the proposed controller is studied with the conventional PID controller, the classical Two-Degree-of-Freedom PID (2-DOF-PID) controller, and the Two Degree-of-Freedom Fractional Order PID controller (2DOF FOPID). The elemental intension of designing supplementary controllers is to diminish the area of control error (ACE). The Crow search algorithm (CSA) is chosen to determine the optimal values of controller gain parameters in order to curtail the figure of demerit. The dynamic behavior of the system is investigated pertaining to a 0.01 p.u. load disturbance in area 1. The performance of the designed controller is explored using wind integration and an CSA optimized small hydro power plant. Investigations reveal that the transient response is superior using the 2-DOF-Combined FOPID concerning the stability indices viz. overshoot (Osh), undershoot (Ush), and settling time response of the power system.
- 2 December 2022
- Published by Wiley
Open AccessImplementation of Crow Search Algorithm based two degree of freedom combined fractional order PID controller for AGC of hydro-thermal power system with wind and small hydro power plants
The unceasing efforts to design an optimal controller for automatic generation control (AGC) in power systems motivate the design of a novel Two-Degree-of-Freedom-Combined Fractional Order PID (2-DOF-Combined FOPID) controller. Two-area interconnected power systems comprised of reheated thermal and hydro units with boiler dynamics, generator rate constraints and dead zone non-linearity in each area are tested using the designed controller. The performance of the proposed controller is studied with the conventional PID controller, the classical Two-Degree-of-Freedom PID (2-DOF-PID) controller, and the Two Degree-of-Freedom Fractional Order PID controller (2DOF FOPID). The elemental intension of designing supplementary controllers is to diminish the area of control error (ACE). The Crow search algorithm (CSA) is chosen to determine the optimal values of controller gain parameters in order to curtail the figure of demerit. The dynamic behavior of the system is investigated pertaining to a 0.01 p.u. load disturbance in area 1. The performance of the designed controller is explored using wind integration and an CSA optimized small hydro power plant. Investigations reveal that the transient response is superior using the 2-DOF-Combined FOPID concerning the stability indices viz. overshoot (Osh), undershoot (Ush), and settling time response of the power system.
- 9 November 2022
- Published by Springer Nature
- p. 563-570
Frequency Control of Wind Integrated Isolated Power System with I-PD Controller
- 9 November 2022
- Published by Springer Nature
- p. 563-570
Frequency Control of Wind Integrated Isolated Power System with I-PD Controller
- 19 September 2022
- Published by Springer Nature
- p. 211-221
Automatic Generation Control of Hydro-Thermal Power System Using 2DOF Fractional Order PID Controller Optimized with Crow Search Algorithm
- 19 September 2022
- Published by Springer Nature
- p. 211-221
Automatic Generation Control of Hydro-Thermal Power System Using 2DOF Fractional Order PID Controller Optimized with Crow Search Algorithm
- Open Access
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 7 (1) , 1-16
A new two-degree of freedom combined PID controller for automatic generation control of a wind integrated interconnected power system
Frequency control of an interconnected power system in the presence of wind integration is complex since wind speed/power variations also affect system frequency in addition to load perturbations. Therefore, improving existing control schemes is necessary to maintain a stable frequency in such complex power system scenarios. In this paper, a new 2-degree of freedom combined proportional-integral and derivative control scheme is applied to a wind integrated interconnected power system. In designing the controller, several inputs used for a secondary frequency control loop are considered along with the merits of the existing controllers. The combined controller provides better control action than existing controllers in the presence of wind as is evidenced by the wide variety of results presented. For tuning of the controller gains, a crow search optimization algorithm (CRSOA) is used. Results are obtained via the MATLAB/Simulink software.
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 7 (1) , 1-16
Open AccessA new two-degree of freedom combined PID controller for automatic generation control of a wind integrated interconnected power system
Frequency control of an interconnected power system in the presence of wind integration is complex since wind speed/power variations also affect system frequency in addition to load perturbations. Therefore, improving existing control schemes is necessary to maintain a stable frequency in such complex power system scenarios. In this paper, a new 2-degree of freedom combined proportional-integral and derivative control scheme is applied to a wind integrated interconnected power system. In designing the controller, several inputs used for a secondary frequency control loop are considered along with the merits of the existing controllers. The combined controller provides better control action than existing controllers in the presence of wind as is evidenced by the wide variety of results presented. For tuning of the controller gains, a crow search optimization algorithm (CRSOA) is used. Results are obtained via the MATLAB/Simulink software.
- 20 March 2018
- Published by Springer Nature
- p. 707-716
Fuzzy Controller-Based Intelligent Operation of Grid-Connected DFIG During Recurring Symmetrical Faults
- 20 March 2018
- Published by Springer Nature
- p. 707-716
Fuzzy Controller-Based Intelligent Operation of Grid-Connected DFIG During Recurring Symmetrical Faults
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 445-449
Investigation on Shunt Active Filter with P-Q Theory
By using a bulky amount of non-linear loads, power electronic equipments, commercial and even residential electrical equipments are causing deterioration of the quality of the electric supply through distortion of supply voltage. This will lead to development of more stringent requirements regarding harmonic current generation, which are found in IEEE519 and IEC61000. The active filters have been used to frontier the flow of harmonic currents in both transmission and distribution systems. But the presentation of the active power filter seems with various control strategies. This article gives the in depth analysis to evaluate the performance of shunt active filter for extracting the current references under steady and transient for both balanced and unbalanced conditions by using PI controller. The instantaneous real active and reactive power control strategy which is widely used in shunt active filter. The wide-ranging simulations are carried out with PI controller for p q control strategy for various voltage conditions.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 445-449
Investigation on Shunt Active Filter with P-Q Theory
By using a bulky amount of non-linear loads, power electronic equipments, commercial and even residential electrical equipments are causing deterioration of the quality of the electric supply through distortion of supply voltage. This will lead to development of more stringent requirements regarding harmonic current generation, which are found in IEEE519 and IEC61000. The active filters have been used to frontier the flow of harmonic currents in both transmission and distribution systems. But the presentation of the active power filter seems with various control strategies. This article gives the in depth analysis to evaluate the performance of shunt active filter for extracting the current references under steady and transient for both balanced and unbalanced conditions by using PI controller. The instantaneous real active and reactive power control strategy which is widely used in shunt active filter. The wide-ranging simulations are carried out with PI controller for p q control strategy for various voltage conditions.