Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takanori Sasaki has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modified Basket Suture for a Floppy or Irregular Iris in Endothelial Keratoplasty

    by Sho Ishikawa, Takanori Sasaki, Takahumi Maruyama, Kei Shinoda

    Performing endothelial keratoplasty in an eye with a damaged or irregular iris can result in uneven air filling, air escape behind the pupil, anterior iris curvature, a shallow anterior chamber, an uneven anterior chamber depth, difficulty inserting and opening the graft, and iris trauma. We herein present a modified basket suture technique to prevent these iris complications. Before insertion of the corneal donor graft, a double-armed 9-0 polypropylene suture on a curved needle is inserted from 4 equidistant points at the corneal limbus to create a box configuration directly anterior to the iris. These sutures prevent the iris from moving toward the cornea and the anterior chamber from becoming shallow when air replacement is performed. The suture also reduces intraoperative or postoperative iris-related problems because the air filling is more uniform and less prone to migration.


  • Open Access

    Effectiveness and Adherence of Dry Eye Patients Who Switched from Short- to Long-Acting Diquafosol Ophthalmic Solution

    by Sho Ishikawa, Takanori Sasaki, Takahumi Maruyama, Koichiro Murayama, Kei Shinoda

    Long-acting (lasting extend) diquafosol ophthalmic solution 3% (DQSLX) is administered three times daily versus six times daily for the currently approved diquafosol ophthalmic solution (DQS). We investigated the efficacy and adherence of switching from DQS to DQSLX in patients with dry eye disease. We retrospectively enrolled 54 patients (17 men and 37 women) with eye drop prescription changes from DQS to DQSLX between December 2022 and March 2023. The number of eye drops, subjective symptoms, tear breakup time (TBUT), and fluorescein staining scores from baseline to 4 weeks after starting DQSLX were evaluated. Participants then chose between DQSLX and DQS. Patients administered DQSLX three times per day, as listed on the package insert, 88.9% of the time; significantly higher than the 5.6% of patients who used DQS six times per day, as instructed. The DQSLX group showed significant improvements in symptoms and fluorescein staining scores (23.3 ± 20.1 and 0.8 ± 1.7, respectively) compared with the baseline (37.8 ± 24.1 and 1.1 ± 1.5, p = 0.01 and p = 0.75). Fifty-one (94.4%) patients opted to continue DQSLX because of the pleasant feeling of the eye drops, long-lasting moisture, and less frequent administration. The efficacy and adherence of DQSLX was comparable to DQS.


  • Open Access

    Correction: Sasaki et al. Automatic Determination of the Center of Macular Hole Using Optical Coherence Tomography En Face Images. J. Clin. Med. 2022, 11, 3167

    by Takanori Sasaki, Takuhei Shoji, Junji Kanno, Hirokazu Ishii, Yuji Yoshikawa, Hisashi Ibuki, Kei Shinoda

    There was an error in the original publication

  • Open Access

    Deep Learning with a Dataset Created Using Kanno Saitama Macro, a Self-Made Automatic Foveal Avascular Zone Extraction Program

    by Junji Kanno, Takuhei Shoji, Hirokazu Ishii, Hisashi Ibuki, Yuji Yoshikawa, Takanori Sasaki, Kei Shinoda

    The extraction of the foveal avascular zone (FAZ) from optical coherence tomography angiography (OCTA) images has been used in many studies in recent years due to its association with various ophthalmic diseases. In this study, we investigated the utility of a dataset for deep learning created using Kanno Saitama Macro (KSM), a program that automatically extracts the FAZ using swept-source OCTA. The test data included 40 eyes of 20 healthy volunteers. For training and validation, we used 257 eyes from 257 patients. The FAZ of the retinal surface image was extracted using KSM, and a dataset for FAZ extraction was created. Based on that dataset, we conducted a training test using a typical U-Net. Two examiners manually extracted the FAZ of the test data, and the results were used as gold standards to compare the Jaccard coefficients between examiners, and between each examiner and the U-Net. The Jaccard coefficient was 0.931 between examiner 1 and examiner 2, 0.951 between examiner 1 and the U-Net, and 0.933 between examiner 2 and the U-Net. The Jaccard coefficients were significantly better between examiner 1 and the U-Net than between examiner 1 and examiner 2 (p < 0.001). These data indicated that the dataset generated by KSM was as good as, if not better than, the agreement between examiners using the manual method. KSM may contribute to reducing the burden of annotation in deep learning.


  • Open Access

    Automatic Determination of the Center of Macular Hole Using Optical Coherence Tomography En Face Images

    by Takanori Sasaki, Takuhei Shoji, Junji Kanno, Hirokazu Ishii, Yuji Yoshikawa, Hisashi Ibuki, Kei Shinoda

    To evaluate the automated determination of the center of an idiopathic macular hole (MH) by using swept-source optical coherence tomography (OCT) images with new macro-based algorithms in ImageJ and to compare the difference between the MH center measurements obtained automatically and manually. This cross-sectional study included 39 eyes of 39 elderly individuals (22 women, 17 men) with stage 3 and 4 MH. The MH center was automatically determined using the ImageJ macro. The foveal center was also manually identified by two masked examiners using horizontal and vertical serial B-scan OCT angiography images. The mean age was 68.8 ± 8.3 years. After adjusting for the effect of magnification, the mean distance between the MH center determined manually by Examiner 1 and that determined automatically was 15.5 ± 9.9 µm. The mean distance between the two manually determined measurements of the MH center was 20.3 ± 19.7 µm. These two mean distance values did not differ significantly (Welch t-test, p = 0.27) and was non-inferior (p < 0.0001). The automated ImageJ-based method for determining the MH center was comparable to manual methods. This study showed that automated measurements were non-inferior to manual measurements, and demonstrated a substitutable usefulness, at least for use in clinical practice.


  • Open Access

    Amnwiotic Membrane Transplantation as a Treatment for Sterile Infiltration and Corneal Melting after Corneal Crosslinking for Keratoconus

    by Takanori Sasaki, Takeshi Ide, Ikuko Toda, Naoko Kato

    We report a case of corneal melting through sterile infiltration presumably due to excessive use of nonsteroidal anti-inflammatory eye drops after corneal crosslinking (CXL). It was treated using steroids combined with amniotic membrane transplantation (AMT). A 33-year-old man with progressing keratoconus underwent left eye CXL. We prescribed betamethasone and levofloxacin eye drops 5 times daily and diclofenac sodium eye drops 3 times daily for 3 days. Three days after CXL, there was a persistent epithelial defect and the left corneal stroma was clouded. His visual acuity remained unchanged. We prescribed betamethasone hourly and 20 mg prednisolone daily. At 1 week after CXL, the corneal epithelial defect and infiltration were unchanged. He had not stopped using diclofenac at the prescribed time. On day 17, we performed AMT and his cornea and visual acuity improved. AMT may be effective against persistent epithelial defects and corneal melting after CXL.