Hirokazu Ishii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hirokazu Ishii has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Kei Shinoda
Department of Ophthalmology, Faculty of Medicine, Saitama Medical University, Saitama, Japan
5 shared publications - Takuhei Shoji
Department of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan
5 shared publications - Junji Kanno
Department of Ophthalmology, Saitama Medical University, Saitama 350-0495, Japan
3 shared publications - Takanori Sasaki
Department of Ophthalmology, Saitama Medical University, Saitama 350-0495, Japan
3 shared publications - Yuji Yoshikawa
Department of Ophthalmology, Saitama Medical University, Saitama 350-0495, Japan
3 shared publications - Hisashi Ibuki
Department of Ophthalmology, Saitama Medical University, Saitama 350-0495, Japan
2 shared publications
Latest Publications
- Open Access
- 7 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 461
Objective Macular Asymmetry Metrics for Glaucoma Detection Using a Temporal Raphe–Based OCT Linearization Algorithm
Background/Objectives: We aim to develop an image linearization process and a program capable of quantifying vertical and left–right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients with unilateral open-angle glaucoma and analyzed paired data (glaucomatous eye vs. fellow normal eye). Spectral-domain OCT images were automatically processed by a custom program to align the disc–fovea axis and temporal raphe, and the following parameters were evaluated: (1) mean inner retinal thickness difference (superior–inferior), (2) Vertical Asymmetry Score, and (3) Quadrantal Asymmetry Score. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thicknesses for the normal and POAG groups were 93.4 µm (interquartile range [IQR]: 90.1–98.5) and 80.3 µm (IQR: 77.3–85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15–7.25) for healthy eyes and 9.69 (IQR: 9.16–11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94–7.19) for healthy eyes and 8.47 (IQR: 8.11–9.63) for POAG eyes. Significant differences were found between groups for all parameters (p < 0.001). The Vertical Asymmetry Score (AUC = 0.967, p < 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p < 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusions: The developed linearization program and asymmetry scores have shown promise as parameters for objectively quantifying macular asymmetry using spectral-domain OCT. External validation in independent cohorts, including bilateral disease, is warranted.
- 7 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 461
Open AccessObjective Macular Asymmetry Metrics for Glaucoma Detection Using a Temporal Raphe–Based OCT Linearization Algorithm
Background/Objectives: We aim to develop an image linearization process and a program capable of quantifying vertical and left–right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients with unilateral open-angle glaucoma and analyzed paired data (glaucomatous eye vs. fellow normal eye). Spectral-domain OCT images were automatically processed by a custom program to align the disc–fovea axis and temporal raphe, and the following parameters were evaluated: (1) mean inner retinal thickness difference (superior–inferior), (2) Vertical Asymmetry Score, and (3) Quadrantal Asymmetry Score. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thicknesses for the normal and POAG groups were 93.4 µm (interquartile range [IQR]: 90.1–98.5) and 80.3 µm (IQR: 77.3–85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15–7.25) for healthy eyes and 9.69 (IQR: 9.16–11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94–7.19) for healthy eyes and 8.47 (IQR: 8.11–9.63) for POAG eyes. Significant differences were found between groups for all parameters (p < 0.001). The Vertical Asymmetry Score (AUC = 0.967, p < 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p < 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusions: The developed linearization program and asymmetry scores have shown promise as parameters for objectively quantifying macular asymmetry using spectral-domain OCT. External validation in independent cohorts, including bilateral disease, is warranted.
- Open Access
- 24 November 2025
- Published by MDPI AG in Preprints.org
Objective Macular Asymmetry Metrics for Glaucoma Detection Using a Temporal Raphe–Based OCT Linearization Algorithm
Background/Aims: To develop an image linearization process and a program capable of quantifying vertical and left-right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients diagnosed with open-angle glaucoma in one eye, with the other eye being normal. Spectral-domain OCT images were automatically processed by a program we developed to straighten the disc-macula and macula-temporal raphe lines. The following parameters were then analyzed: 1) Mean inner retinal thickness difference between the superior and inferior segments, 2) Vertical Asymmetry Score, and 3) Quadrantal Asymmetry Score. These parameters were automatically measured, and their values were compared between the two eyes.. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thickness for the normal and POAG groups was 93.4 µm (interquartile range [IQR]: 90.1-98.5) and 80.3 µm (IQR: 77.3-85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15-7.25) for healthy eyes and 9.69 (IQR: 9.16-11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94-7.19) for healthy eyes and 8.47 (IQR: 8.11-9.63) for POAG eyes. Significant differences were found between groups for all parameters (p< 0.001). The Vertical Asymmetry Score (AUC = 0.967, p< 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p< 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusion: The developed linearization program and asymmetry scores have shown promise as parameters for detecting glaucomatous changes in macular scans using spectral-domain OCT.
- 24 November 2025
- Published by MDPI AG in Preprints.org
Open AccessObjective Macular Asymmetry Metrics for Glaucoma Detection Using a Temporal Raphe–Based OCT Linearization Algorithm
Background/Aims: To develop an image linearization process and a program capable of quantifying vertical and left-right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients diagnosed with open-angle glaucoma in one eye, with the other eye being normal. Spectral-domain OCT images were automatically processed by a program we developed to straighten the disc-macula and macula-temporal raphe lines. The following parameters were then analyzed: 1) Mean inner retinal thickness difference between the superior and inferior segments, 2) Vertical Asymmetry Score, and 3) Quadrantal Asymmetry Score. These parameters were automatically measured, and their values were compared between the two eyes.. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thickness for the normal and POAG groups was 93.4 µm (interquartile range [IQR]: 90.1-98.5) and 80.3 µm (IQR: 77.3-85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15-7.25) for healthy eyes and 9.69 (IQR: 9.16-11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94-7.19) for healthy eyes and 8.47 (IQR: 8.11-9.63) for POAG eyes. Significant differences were found between groups for all parameters (p< 0.001). The Vertical Asymmetry Score (AUC = 0.967, p< 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p< 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusion: The developed linearization program and asymmetry scores have shown promise as parameters for detecting glaucomatous changes in macular scans using spectral-domain OCT.
- Open Access
- 3 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 392
Correction: Sasaki et al. Automatic Determination of the Center of Macular Hole Using Optical Coherence Tomography En Face Images. J. Clin. Med. 2022, 11, 3167
There was an error in the original publication
- 3 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 392
Open AccessCorrection: Sasaki et al. Automatic Determination of the Center of Macular Hole Using Optical Coherence Tomography En Face Images. J. Clin. Med. 2022, 11, 3167
There was an error in the original publication
- Open Access
- 26 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 183
Deep Learning with a Dataset Created Using Kanno Saitama Macro, a Self-Made Automatic Foveal Avascular Zone Extraction Program
The extraction of the foveal avascular zone (FAZ) from optical coherence tomography angiography (OCTA) images has been used in many studies in recent years due to its association with various ophthalmic diseases. In this study, we investigated the utility of a dataset for deep learning created using Kanno Saitama Macro (KSM), a program that automatically extracts the FAZ using swept-source OCTA. The test data included 40 eyes of 20 healthy volunteers. For training and validation, we used 257 eyes from 257 patients. The FAZ of the retinal surface image was extracted using KSM, and a dataset for FAZ extraction was created. Based on that dataset, we conducted a training test using a typical U-Net. Two examiners manually extracted the FAZ of the test data, and the results were used as gold standards to compare the Jaccard coefficients between examiners, and between each examiner and the U-Net. The Jaccard coefficient was 0.931 between examiner 1 and examiner 2, 0.951 between examiner 1 and the U-Net, and 0.933 between examiner 2 and the U-Net. The Jaccard coefficients were significantly better between examiner 1 and the U-Net than between examiner 1 and examiner 2 (p < 0.001). These data indicated that the dataset generated by KSM was as good as, if not better than, the agreement between examiners using the manual method. KSM may contribute to reducing the burden of annotation in deep learning.
- 26 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 183
Open AccessDeep Learning with a Dataset Created Using Kanno Saitama Macro, a Self-Made Automatic Foveal Avascular Zone Extraction Program
The extraction of the foveal avascular zone (FAZ) from optical coherence tomography angiography (OCTA) images has been used in many studies in recent years due to its association with various ophthalmic diseases. In this study, we investigated the utility of a dataset for deep learning created using Kanno Saitama Macro (KSM), a program that automatically extracts the FAZ using swept-source OCTA. The test data included 40 eyes of 20 healthy volunteers. For training and validation, we used 257 eyes from 257 patients. The FAZ of the retinal surface image was extracted using KSM, and a dataset for FAZ extraction was created. Based on that dataset, we conducted a training test using a typical U-Net. Two examiners manually extracted the FAZ of the test data, and the results were used as gold standards to compare the Jaccard coefficients between examiners, and between each examiner and the U-Net. The Jaccard coefficient was 0.931 between examiner 1 and examiner 2, 0.951 between examiner 1 and the U-Net, and 0.933 between examiner 2 and the U-Net. The Jaccard coefficients were significantly better between examiner 1 and the U-Net than between examiner 1 and examiner 2 (p < 0.001). These data indicated that the dataset generated by KSM was as good as, if not better than, the agreement between examiners using the manual method. KSM may contribute to reducing the burden of annotation in deep learning.
- Open Access
- 2 June 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (11) , 3167
Automatic Determination of the Center of Macular Hole Using Optical Coherence Tomography En Face Images
To evaluate the automated determination of the center of an idiopathic macular hole (MH) by using swept-source optical coherence tomography (OCT) images with new macro-based algorithms in ImageJ and to compare the difference between the MH center measurements obtained automatically and manually. This cross-sectional study included 39 eyes of 39 elderly individuals (22 women, 17 men) with stage 3 and 4 MH. The MH center was automatically determined using the ImageJ macro. The foveal center was also manually identified by two masked examiners using horizontal and vertical serial B-scan OCT angiography images. The mean age was 68.8 ± 8.3 years. After adjusting for the effect of magnification, the mean distance between the MH center determined manually by Examiner 1 and that determined automatically was 15.5 ± 9.9 µm. The mean distance between the two manually determined measurements of the MH center was 20.3 ± 19.7 µm. These two mean distance values did not differ significantly (Welch t-test, p = 0.27) and was non-inferior (p < 0.0001). The automated ImageJ-based method for determining the MH center was comparable to manual methods. This study showed that automated measurements were non-inferior to manual measurements, and demonstrated a substitutable usefulness, at least for use in clinical practice.
- 2 June 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (11) , 3167
Open AccessAutomatic Determination of the Center of Macular Hole Using Optical Coherence Tomography En Face Images
To evaluate the automated determination of the center of an idiopathic macular hole (MH) by using swept-source optical coherence tomography (OCT) images with new macro-based algorithms in ImageJ and to compare the difference between the MH center measurements obtained automatically and manually. This cross-sectional study included 39 eyes of 39 elderly individuals (22 women, 17 men) with stage 3 and 4 MH. The MH center was automatically determined using the ImageJ macro. The foveal center was also manually identified by two masked examiners using horizontal and vertical serial B-scan OCT angiography images. The mean age was 68.8 ± 8.3 years. After adjusting for the effect of magnification, the mean distance between the MH center determined manually by Examiner 1 and that determined automatically was 15.5 ± 9.9 µm. The mean distance between the two manually determined measurements of the MH center was 20.3 ± 19.7 µm. These two mean distance values did not differ significantly (Welch t-test, p = 0.27) and was non-inferior (p < 0.0001). The automated ImageJ-based method for determining the MH center was comparable to manual methods. This study showed that automated measurements were non-inferior to manual measurements, and demonstrated a substitutable usefulness, at least for use in clinical practice.