Kohei Hanaoka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kohei Hanaoka has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Kazunari Ishii
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
4 shared publications Hayato Kaida
Division of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University Hospital, 377-2 Ohno-Higashi, 589-8511, Osakasayama, Osaka, Japan; Department of Radiology, Kindai University Faculty of Medicine, Osakasayama, Japan
3 shared publicationsKazunari Ishii
Division of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University Hospital, 377-2 Ohno-Higashi, 589-8511, Osakasayama, Osaka, Japan; Department of Radiology, Kindai University Faculty of Medicine, Osakasayama, Japan
3 shared publicationsShota Watanabe
Division of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University Hospital, 377-2 Ohno-Higashi, 589-8511, Osakasayama, Osaka, Japan
3 shared publicationsTakahiro Yamada
Division of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University Hospital, 377-2 Ohno-Higashi, 589-8511, Osakasayama, Osaka, Japan
3 shared publicationsAtsushi Ohtani
Medical Systems Division, Shimadzu Corporation, Kyoto, Japan
2 shared publications
Latest Publications
- 3 August 2026
- Published by Springer Nature
- p. 618-632
FDG-PET Image Diagnosis Using Multi-angle Projection Analysis with Coupled Weakly and Fully Supervised Frameworks
- 3 August 2026
- Published by Springer Nature
- p. 618-632
FDG-PET Image Diagnosis Using Multi-angle Projection Analysis with Coupled Weakly and Fully Supervised Frameworks
- 20 November 2024
- Published by Springer Nature in Neuroradiology
- Vol. 67 (1) , 79-87
The eagle-wing finding in FP-CIT SPECT, as a characteristic finding in patients with DESH- type iNPH
Purpose Although dopamine transporter (DAT) imaging has been reported to be useful for differentiating idiopathic Normal Pressure Hydrocephalus (iNPH) from its mimics, the radiological findings of DAT imaging in iNPH have not been established. We investigated [123I] N-ω-fluoropropyl-2β-carboxymethoxy-3β-(4-iodophenyl) nortropane (FP-CIT) single photon emission computed tomography (SPECT) images from patients with disproportionately enlarged subarachnoid-space hydrocephalus (DESH)-type iNPH to understand the characteristics of DAT images of iNPH. Methods We retrospectively collected 11 DESH-type iNPH patients without comorbidities who underwent FP-CIT SPECT imaging. The patients’ FP-CIT SPECT were examined using both visual and quantitative evaluations. Visual assessment used Kahraman et al.’s five-step grading, and quantitative assessment used DaTView and MIM software to calculate specific binding ratios (SBRs) for four volumes of interest (VOIs): the entire striatum, caudate nucleus, anterior putamen, and posterior putamen. Intergroup comparisons were made between the DESH group and a normal control (NC) group adjusted for age and sex. Results The visual assessment classified 91% of DESH patients as showing grade 4 ‘eagle-wing’ on FP-CIT SPECT, with a Kappa coefficient of 0.601. The median SBR was lower in the DESH group than in the NC group for all four VOIs, and significantly lower in the anterior and posterior putamen (p < 0.05). Conclusion In DESH-type iNPH, FP-CIT SPECT imaging typically shows the ‘eagle-wing’ finding due to decreased DAT concentration in the putamen. Our results enhance the utility of FP-CIT SPECT in diagnosing iNPH and distinguishing it from mimics.
- 20 November 2024
- Published by Springer Nature in Neuroradiology
- Vol. 67 (1) , 79-87
The eagle-wing finding in FP-CIT SPECT, as a characteristic finding in patients with DESH- type iNPH
Purpose Although dopamine transporter (DAT) imaging has been reported to be useful for differentiating idiopathic Normal Pressure Hydrocephalus (iNPH) from its mimics, the radiological findings of DAT imaging in iNPH have not been established. We investigated [123I] N-ω-fluoropropyl-2β-carboxymethoxy-3β-(4-iodophenyl) nortropane (FP-CIT) single photon emission computed tomography (SPECT) images from patients with disproportionately enlarged subarachnoid-space hydrocephalus (DESH)-type iNPH to understand the characteristics of DAT images of iNPH. Methods We retrospectively collected 11 DESH-type iNPH patients without comorbidities who underwent FP-CIT SPECT imaging. The patients’ FP-CIT SPECT were examined using both visual and quantitative evaluations. Visual assessment used Kahraman et al.’s five-step grading, and quantitative assessment used DaTView and MIM software to calculate specific binding ratios (SBRs) for four volumes of interest (VOIs): the entire striatum, caudate nucleus, anterior putamen, and posterior putamen. Intergroup comparisons were made between the DESH group and a normal control (NC) group adjusted for age and sex. Results The visual assessment classified 91% of DESH patients as showing grade 4 ‘eagle-wing’ on FP-CIT SPECT, with a Kappa coefficient of 0.601. The median SBR was lower in the DESH group than in the NC group for all four VOIs, and significantly lower in the anterior and posterior putamen (p < 0.05). Conclusion In DESH-type iNPH, FP-CIT SPECT imaging typically shows the ‘eagle-wing’ finding due to decreased DAT concentration in the putamen. Our results enhance the utility of FP-CIT SPECT in diagnosing iNPH and distinguishing it from mimics.
- 14 March 2023
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 30 (5) , 1879-1885
Impact of respiratory gating and ECG gating on 18F-FDG PET/CT for cardiac sarcoidosis
- 14 March 2023
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 30 (5) , 1879-1885
Impact of respiratory gating and ECG gating on 18F-FDG PET/CT for cardiac sarcoidosis
- Open Access
- 13 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1079
Organ-Specific Positron Emission Tomography Scanners for Breast Imaging: Comparison between the Performances of Prior and Novel Models
The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3–10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various β-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher β and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.
- 13 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1079
Open AccessOrgan-Specific Positron Emission Tomography Scanners for Breast Imaging: Comparison between the Performances of Prior and Novel Models
The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3–10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various β-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher β and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.
- Open Access
- 16 December 2022
- Published by Springer Nature in EJNMMI Physics
- Vol. 9 (1) , 1-12
Evaluation of the performance of a high-resolution time-of-flight PET system dedicated to the head and breast according to NEMA NU 2-2012 standard
Background: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. Methods: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures. Results: The tangential, radial, and axial full width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset was 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods was clearly visualized. Conclusion: Taken together, these results indicate that the head- and breast-dedicated PET system has high resolution and is well suited for clinical PET imaging.
- 16 December 2022
- Published by Springer Nature in EJNMMI Physics
- Vol. 9 (1) , 1-12
Open AccessEvaluation of the performance of a high-resolution time-of-flight PET system dedicated to the head and breast according to NEMA NU 2-2012 standard
Background: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. Methods: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures. Results: The tangential, radial, and axial full width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset was 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods was clearly visualized. Conclusion: Taken together, these results indicate that the head- and breast-dedicated PET system has high resolution and is well suited for clinical PET imaging.
- Open Access
- 3 June 2022
- Published by Springer Nature in Research Square
Evaluation of the Performance of a High-Resolution Time-of-Flight PET System Dedicated to the Head and Breast according to NEMA NU 2-2012 Standard
Background: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. Methods: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures.Results: The tangential, radial, and axial full-width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset were 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods were clearly visualized. Conclusion: Taken together, these results indicate that the head and breast-dedicated PET system has high-resolution and is well suited for clinical PET imaging.
- 3 June 2022
- Published by Springer Nature in Research Square
Open AccessEvaluation of the Performance of a High-Resolution Time-of-Flight PET System Dedicated to the Head and Breast according to NEMA NU 2-2012 Standard
Background: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. Methods: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures.Results: The tangential, radial, and axial full-width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset were 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods were clearly visualized. Conclusion: Taken together, these results indicate that the head and breast-dedicated PET system has high-resolution and is well suited for clinical PET imaging.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 3680-3683
Application of correlated component analysis to dynamic PET time-activity curves denoising
Positron emission tomography (PET) is a physiological, non-invasive imaging technique, which forms an essential part of nuclear medicine. The data obtained in a PET scan represent the concentration of an administered radiotracer in tissues over time. Quantitative analysis of PET data makes possible the assessments of in-vivo physiological processes. The Logan graphical analysis (LGA) is one of the methods that are used for quantitative analysis of PET data. LGA transforms PET data into a simple linear relationship. The slope of the LGA linear relationship is a physiological quantity denoting receptor availability. This quantity is termed distribution volume ratio (DVR). LGA-based estimates of the DVR are negatively affected by the noise in PET data —leading to the DVR being underestimated. A number of approaches proposed to address this issue have been observed to reduce the bias at the cost precision. An alternative regression method, least-squares cubic (LSC), was recently applied to estimate the DVR in order to reduce the bias. LSC was observed to reduce the bias in the LGA-based estimates. However, slight increases were also observed in the variance of the LSC-based estimates. This calls for methods to act against the variance in the LSC-based estimates. In this study, an alternative method is applied for tTAC denoising. This method is referred to as correlated component analysis (CorrCA). CorrCA transform the data by searching for dimensions of maximum correlation. This technique is closely related to other well-known methods such as principal component analysis and independent component analysis. In this study, the data were denoised by CorrCA (to act against the variance in the estimate) and the DVR was estimated by LSC, which provides for minimal bias. The resulting method LSC-CorrCA, gave less-biased estimated with increased precision. This was observed for both simulation results as well as for clinical data, both for 11 C Pittsburgh compound B. Simulation data revealed reduced variances in LCS-CorrCA-based estimates, and the clinical data showed improved contrast between gray and white matter regions.Clinical Relevance—Improved DVR estimates would ease the interpretation of medical images, which will in turn positively influence the clinical processes, from diagnosis to treatment and follow-ups.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 3680-3683
Application of correlated component analysis to dynamic PET time-activity curves denoising
Positron emission tomography (PET) is a physiological, non-invasive imaging technique, which forms an essential part of nuclear medicine. The data obtained in a PET scan represent the concentration of an administered radiotracer in tissues over time. Quantitative analysis of PET data makes possible the assessments of in-vivo physiological processes. The Logan graphical analysis (LGA) is one of the methods that are used for quantitative analysis of PET data. LGA transforms PET data into a simple linear relationship. The slope of the LGA linear relationship is a physiological quantity denoting receptor availability. This quantity is termed distribution volume ratio (DVR). LGA-based estimates of the DVR are negatively affected by the noise in PET data —leading to the DVR being underestimated. A number of approaches proposed to address this issue have been observed to reduce the bias at the cost precision. An alternative regression method, least-squares cubic (LSC), was recently applied to estimate the DVR in order to reduce the bias. LSC was observed to reduce the bias in the LGA-based estimates. However, slight increases were also observed in the variance of the LSC-based estimates. This calls for methods to act against the variance in the LSC-based estimates. In this study, an alternative method is applied for tTAC denoising. This method is referred to as correlated component analysis (CorrCA). CorrCA transform the data by searching for dimensions of maximum correlation. This technique is closely related to other well-known methods such as principal component analysis and independent component analysis. In this study, the data were denoised by CorrCA (to act against the variance in the estimate) and the DVR was estimated by LSC, which provides for minimal bias. The resulting method LSC-CorrCA, gave less-biased estimated with increased precision. This was observed for both simulation results as well as for clinical data, both for 11 C Pittsburgh compound B. Simulation data revealed reduced variances in LCS-CorrCA-based estimates, and the clinical data showed improved contrast between gray and white matter regions.Clinical Relevance—Improved DVR estimates would ease the interpretation of medical images, which will in turn positively influence the clinical processes, from diagnosis to treatment and follow-ups.
- 1 August 2011
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 32 (8) , 678-683
Fluorodeoxyglucose uptake in the bone marrow after granulocyte colony-stimulating factor administration in patients with non-Hodgkin's lymphoma
Purpose To clarify the change in the fluorodeoxyglucose (FDG) uptake by the bone marrow over time after administration of granulocyte colony-stimulating factor (G-CSF), we evaluated the correlation between the interval from the last day of administration of G-CSF to positron emission tomography/computed tomography (PET/CT) study and spinal bone marrow accumulation in patients with non-Hodgkin's lymphoma. Methods A total of 127 patients with confirmed non-Hodgkin's lymphoma who underwent FDG PET within 60 days from the last administration of G-CSF were retrospectively reviewed. Thirty age-matched and sex-matched healthy controls were also included to evaluate physiological FDG uptake. PET/CT examinations were retrospectively reviewed, and maximum standardized uptake value (SUVmax) was measured by placing volumetric regions of interest over each thoracic and lumbar vertebra on PET images referring to CT images. Bone marrow SUV was defined as the mean SUVmax of the vertebra. The correlation between the interval after G-CSF and the bone marrow SUV was plotted and analyzed with polynomial approximation. Results In controls, physiological bone marrow SUV of the spine was determined. In patients with lymphoma, bone marrow SUV decreased over time and reached a plateau at about 14 days after G-CSF administration, and this was higher by 5% than the plateau at 10 days. SUV declined to the ‘physiological range’, that is, mean+1 standard deviation of patients, at about 7 days. Conclusion For a PET/CT study, an interval of 10 days after G-CSF administration is recommended to minimize the influence of G-CSF on the bone marrow when evaluating treatment response in patients with non-Hodgkin's lymphoma.
- 1 August 2011
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 32 (8) , 678-683
Fluorodeoxyglucose uptake in the bone marrow after granulocyte colony-stimulating factor administration in patients with non-Hodgkin's lymphoma
Purpose To clarify the change in the fluorodeoxyglucose (FDG) uptake by the bone marrow over time after administration of granulocyte colony-stimulating factor (G-CSF), we evaluated the correlation between the interval from the last day of administration of G-CSF to positron emission tomography/computed tomography (PET/CT) study and spinal bone marrow accumulation in patients with non-Hodgkin's lymphoma. Methods A total of 127 patients with confirmed non-Hodgkin's lymphoma who underwent FDG PET within 60 days from the last administration of G-CSF were retrospectively reviewed. Thirty age-matched and sex-matched healthy controls were also included to evaluate physiological FDG uptake. PET/CT examinations were retrospectively reviewed, and maximum standardized uptake value (SUVmax) was measured by placing volumetric regions of interest over each thoracic and lumbar vertebra on PET images referring to CT images. Bone marrow SUV was defined as the mean SUVmax of the vertebra. The correlation between the interval after G-CSF and the bone marrow SUV was plotted and analyzed with polynomial approximation. Results In controls, physiological bone marrow SUV of the spine was determined. In patients with lymphoma, bone marrow SUV decreased over time and reached a plateau at about 14 days after G-CSF administration, and this was higher by 5% than the plateau at 10 days. SUV declined to the ‘physiological range’, that is, mean+1 standard deviation of patients, at about 7 days. Conclusion For a PET/CT study, an interval of 10 days after G-CSF administration is recommended to minimize the influence of G-CSF on the bone marrow when evaluating treatment response in patients with non-Hodgkin's lymphoma.