Organ-Specific Positron Emission Tomography Scanners for Breast Imaging: Comparison between the Performances of Prior and Novel Models
Authors:
- Yoko SatohYSYoko Satoh
- Kohei HanaokaKHKohei Hanaoka
- Chihiro IkegawaCIChihiro Ikegawa
- Masamichi ImaiMIMasamichi Imai
- Shota WatanabeSWShota Watanabe
- Daisuke Morimoto-IshikawaDMDaisuke Morimoto-Ishikawa
- Hiroshi OnishiHOHiroshi Onishi
- Toshikazu ItoTIToshikazu Ito
- Yoshifumi KomoikeYKYoshifumi Komoike
- Kazunari IshiiKIKazunari Ishii
Open Access
- 13 March 2023
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1079
Abstract
The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3–10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various β-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher β and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.Keywords
This publication has 26 references indexed in Scilit:
- Effects of menstrual cycle on background parenchymal enhancement and detectability of breast cancer on dynamic contrast-enhanced breast MRI: A multicenter study of an Asian populationEuropean Journal of Radiology, 2019
- The feasibility of dedicated breast PET for the assessment of residual tumor after neoadjuvant chemotherapyJapanese Journal of Radiology, 2018
- Performance evaluation of a high-resolution brain PET scanner using four-layer MPPC DOI detectorsPhysics in Medicine & Biology, 2017
- Generalized PSF modeling for optimized quantitation in PET imagingPhysics in Medicine & Biology, 2017
- A Semi-Automated Technique Determining the Liver Standardized Uptake Value Reference for Tumor Delineation in FDG PET-CTPLOS ONE, 2014
- Performance Evaluation of a New Dedicated Breast PET Scanner Using NEMA NU4-2008 StandardsJournal of Nuclear Medicine, 2014
- Attenuation correction using level set method for application specific PET scanners2011
- A four-Layer depth of interaction detector block for small animal PETIEEE Transactions on Nuclear Science, 2004
- Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomographyPhysics in Medicine & Biology, 2003
- A convolution-subtraction scatter correction method for 3D PETPhysics in Medicine & Biology, 1994