LLLiesbet Lagae

Liesbet Lagae

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liesbet Lagae has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sensitive Optomechanical Ultrasound Sensor in an LED-Based, Low Fluence Photoacoustic Imaging System

    by Cedric Pieters, Tom Verschooten, Grim Keulemans, Liesbet Lagae, Jon Øyvind Kjellman, Xavier Rottenberg, Hilde Jans

    Affordable and compact light sources, along with highly sensitive, broadband, low-noise sensors, are essential for enabling point-of-care photoacoustic imaging applications in resource-limited settings. Traditional systems use piezoelectric transducers, which often suffer from limited bandwidth and sensitivity, combined with solid-state lasers that are expensive and bulky. We present a potentially low-cost LED-based photoacoustic imaging system featuring a highly sensitive optomechanical ultrasound sensor operating near thermomechanical noise limits. Utilizing a 620 nm LED, our setup delivers microjoules of pulse energy with 100 ns pulse widths. We demonstrate its capability to resolve fine details through 2D scan tomography, with minimal averaging for an effective sample rate of 100 Hz. Future improvements, including the development of larger LED arrays, multiplexed sensors and on-chip integrated lasers, promise to enhance performance and further expand the technology's applicability


  • Addressing variability in cell electrorotation through holographic imaging and correction factors

    by Kevin T Uning, Yuqian Li, Ziduo Lin, Giovanni Mangraviti, Liesbet Lagae, Camila D M Campos

    This study addresses the variations observed in electrorotation measurements due to cell positioning and movement. Electrorotation provides a non-disruptive method for inferring the electrical properties of individual cells. However, its widespread adoption is hindered by significant variation in the observed speed. By mitigating the impact of positional dependencies and other influencing factors, our methodology opens avenues for broader applications of electrorotation in single-cell analysis without the need for complex setups to trap and retain the cell in place. Our novel approach combines multi-plane imaging with mathematical treatment of rotation data. This method uses a conventional quadrupole chip and lens-free imaging to track cell movement, resulting in a simpler design and set-up. Through numerical simulations incorporating cell coordinates, chip design, and experimental parameters, we calculate the variation in torque for each position. These values serve as the basis for the correction factors. Validation experiments with T-lymphocytes and fibroblasts show that the correction factors reduce electrorotation speed variation due to cell movement, with an average reduction to 21% and 18%, respectively. These corrections also revealed previously concealed changes in cell properties, in response to external stimuli, thereby enhancing the reliability of measurements and enabling broader applications in single-cell analysis.

  • Study of AC Electrothermal Effect in Microfluidics

    by Zouhir Bouchaar, Ying Ting Set, Liesbet Lagae, Camila D. M. Campos

    Through simulations and experiments, we analyzed the effects of electrode configuration and applied voltage in heating, mixing, and particle enrichment by ac electrothermal effects. We focused on the spacing between groups of electrodes and between finger electrodes within groups. Our findings revealed that having tight groups of electrodes led to more even heating and better mixing. We also highlighted the role of the distance between groups in enhancing particle enrichment and contributed valuable insights for optimizing the design of microfluidic systems.


  • Open Access

    Si/SiO2 silicon-on-insulator based scaffold for interfacing with cerebral organoids

    by Aaron Delahanty, Sohail Faizan Shaikh, Idris Salmon, Alexandru Andrei, Oguzhan Orkut Okudur, Mario Gonzalez, Liesbet Lagae, Adrian Ranga, Dries Braeken

    Cerebral organoids are hSPC derived tissue complexes that self-organize over an extended period and begin to recapitulate certain features of in vivo neurogenesis, and there is a need to develop tools that allow for the physical and electrical interrogation of these cell complexes as they mature. Presented here is a method of manufacturing thin, porous, scalable silicon scaffolds as a structure to support multi-electrode arrays using industry standard semiconductor fabrication techniques. Mechanical tests by nanoindentation demonstrate the scaffold as linearly elastic with an approximated effective stiffness of 51.6 MPa. Biological cell studies indicate that mature Cerebral Organoids are capable of cellular expansion through, and partially absorbing, the scaffold, with 0.125 mm3 ± 0.027 of new tissue generation over a 5-day culture period. The structure is designed for compatibility with front end of line and back end of line semiconductor processes for future integration with metal electrodes, which enables deep tissue access in multi-cellular structures.


  • Use of high frequency electrorotation to identify cytoplasmic changes in cells non-disruptively

    by Camila D. M. Campos, Kevin T. Uning, Pawel Barmuta, Tomislav Markovic, Rahul Yadav, Giovanni Mangraviti, Ilja Ocket, Willem Van Roy, Liesbet Lagae, Chengxun Liu

    In this paper we demonstrate how the use of frequencies ranging from 50 kHz to 5 GHz in the analysis of cells by electrorotation can open the path to the identification of differences not detectable by conventional set-ups. Earlier works usually reported electrorotation devices operating below 20 MHz, limiting the response obtained to properties associated with the cell membrane. Those devices are thus unable to resolve the physiological properties in the cytoplasm. We used microwave-based technology to extend the frequency operation to 5 GHz. At high frequencies (from tens of MHz to GHz), the electromagnetic signal passes through the membrane and allows probing the cytoplasm. This enables several applications, such as cell classification, and viability analysis. Additionally, the use of conventional microfabrication techniques reduces the cost and complexity of analysis, compared to other non-invasive methods. We demonstrated the potential of this set-up by identifying two different populations of T-lymphocytes not distinguishable through visual assessment. We also assessed the effect of calcein on cell cytoplasmic properties and used it as a controlled experiment to demonstrate the possibility of this method to detect changes happening predominantly in the cytoplasm. Graphical Abstract


  • Amplification Efficiency and Template Accessibility as Distinct Causes of Rain in Digital PCR: Monte Carlo Modeling and Experimental Validation

    by Pieter Berden, Rodrigo S. Wiederkehr, Liesbet Lagae, Jan Michiels, Tim Stakenborg, Maarten Fauvart, Willem Van Roy

    Partitions in digital PCR (dPCR) assays do not reach the detection threshold at the same time. This heterogeneity in amplification results in intermediate endpoint fluorescence values (i.e., rain) and misclassification of partitions, which has a major impact on the accuracy of nucleic acid quantification. Rain most often results from a reduced amplification efficiency or template inaccessibility; however, exactly how these contribute to rain has not been described. We developed and experimentally validated an analytical model that mechanistically explains the relationship between amplification efficiency, template accessibility, and rain. Using Monte Carlo simulations, we show that a reduced amplification efficiency leads to broader threshold cycle (Ct) distributions that can be fitted using a log-normal probability distribution. From the fit parameters, the amplification efficiency can be calculated. Template inaccessibility, on the other hand, leads to a different rain pattern, in which a distinct exponential tail in the Ct distribution can be observed. Using our model, it is possible to determine if the amplification efficiency, template accessibility, or another source is the main contributor of rain in dPCR assays. We envision that this model will facilitate and speed up dPCR assay optimization and provide an indication for the accuracy of the assay.


  • Rigorous analysis of the axial acoustic radiation force on a spherical object for single-beam acoustic tweezing applications

    by Bart P. Weekers, Xavier Rottenberg, Liesbet Lagae, Veronique Rochus

    Acoustic tweezers are increasingly utilized for the contactless manipulation of small particles. This paper provides a theoretical model demonstrating the acoustic manipulation capabilities of single-beam acoustic transducers. Analytical formulas are derived for the acoustic radiation force on an isotropic spherical object of arbitrary size, centered on a circular piston, simply supported and clamped radiator in an inviscid fluid. Using these results, the existence of a negative axial force pulling the object closer to the radiator is revealed and explored. These findings offer further insight into the feasibility of trapping objects in the near-field of a single-beam acoustic transducer. The calculations illustrate the trapping capabilities of the different emitters as a function of radiator size, particle size, and distance from the source and highlight the impact of radiator boundary conditions. Manipulation of a cell-like fluid sphere in water and an expanded polystyrene sphere in air are studied in more detail with results that are validated through finite element analysis. The developed theoretical model allows fast evaluation of acoustic radiation forces which could aid in the development of relatively simple and inexpensive contactless manipulation solutions.