Lin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lin Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Qinduan Zhang
Qilu University of Technology (Shandong Academy of Sciences)
1 shared publication - Tingting Zhang
Laser Institute and International School for Optoelectronic Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
1 shared publication - Weihua Gong
Laser Institute and International School for Optoelectronic Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
1 shared publication - Yanfang Li
Larse Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250104, China
1 shared publication - Yubin Wei
Laser Institute, QiLu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
1 shared publication - Zhaowei Wang
Laser Institute and International School for Optoelectronic Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
1 shared publication
Latest Publications
- Open Access
SNR Enhancement of Direct Absorption Spectroscopy Utilizing an Improved Particle Swarm Algorithm
A noise elimination method based on an improved particle swarm algorithm is applied to direct absorption spectroscopy. The algorithm combines the theory of spectral line shape to calculate a fitness function according to the original spectra. Comparing the particles and the fitness function to calculate the updating direction, and position of particles, the iterative update finally finds the optimal solution. The algorithm is applied to direct absorption spectroscopy to measure methane; compared with the signal without algorithm processing, the signal-to-noise ratio (SNR) is improved by 4.17 times, and the minimum detection limit in the experiment is 15.3 ppb. R2 = 0.9999 is calculated in the calibration experiment, and the error is less than 0.1 ppm in the repeatability experiment of constant methane at 2 ppm concentration.
Open AccessSNR Enhancement of Direct Absorption Spectroscopy Utilizing an Improved Particle Swarm Algorithm
A noise elimination method based on an improved particle swarm algorithm is applied to direct absorption spectroscopy. The algorithm combines the theory of spectral line shape to calculate a fitness function according to the original spectra. Comparing the particles and the fitness function to calculate the updating direction, and position of particles, the iterative update finally finds the optimal solution. The algorithm is applied to direct absorption spectroscopy to measure methane; compared with the signal without algorithm processing, the signal-to-noise ratio (SNR) is improved by 4.17 times, and the minimum detection limit in the experiment is 15.3 ppb. R2 = 0.9999 is calculated in the calibration experiment, and the error is less than 0.1 ppm in the repeatability experiment of constant methane at 2 ppm concentration.