Saeid Esmaeili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Saeid Esmaeili has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Mohammad Hossein Rezaeian Koochi
Middleton Group Brisbane QLD Australia
4 shared publicationsSina Shakeri
Electrical Engineering Department Shahid Bahonar University of Kerman Kerman Iran
3 shared publicationsFahimeh Sayadi
Department of Energy Management and Optimization Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology Kerman Iran
2 shared publications- Farshid Keynia
Department of Energy Management and Optimization, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
2 shared publications - Gevork Babamalek Gharehpetian
Amirkabir University of Technology
2 shared publications - Hesam Rahbarimagham
Electrical and Computer Engineering Department, Rafsanjan Branch, Islamic Azad University, Rafsanjan, Iran
2 shared publications
Latest Publications
- Open Access
- 6 November 2025
- Published by Elsevier in Energy Reports
- Vol. 14, 3605-3624
A sustainable energy management model for nearly zero energy smart homes: A multi-objective information gap decision theory approach
- 6 November 2025
- Published by Elsevier in Energy Reports
- Vol. 14, 3605-3624
Open AccessA sustainable energy management model for nearly zero energy smart homes: A multi-objective information gap decision theory approach
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 19 (1)
Harmonic Resonance Monitoring in Distribution Networks Considering Load Variation and Possible Network Configurations
In this paper, three methods based on harmonic resonance mode analysis are proposed for placing PQMs to monitor all harmonic resonance conditions in a power system. These methods compute the optimal number and sites of PQMs for varied load profiles and network configurations such that all harmonic resonance conditions would be monitored. This paper introduces the harmonic resonance severity index that enables electric network owners to place PQMs in a way to monitor only worst‐case harmonic resonance conditions. Also, in this paper, the harmonic resonance observability index is introduced, enabling electrical owners to afford suitable numbers of PQMs based on their budget limitations. The efficiency of the proposed methods has been examined on test systems. The results indicate that using the proposed approach, all harmonic resonance conditions can be captured with an optimal number of PQMs. The proposed approaches also operate with system uncertainties present, which overcomes one of the major weaknesses of the prior approaches. It observes the bus voltage if either this bus or one of the adjacent buses is equipped with at least one PMQ, reduces the number of PQMs, and rearranges their locations to develop a cost‐effective strategy, addressing a long‐standing challenge.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 19 (1)
Open AccessHarmonic Resonance Monitoring in Distribution Networks Considering Load Variation and Possible Network Configurations
In this paper, three methods based on harmonic resonance mode analysis are proposed for placing PQMs to monitor all harmonic resonance conditions in a power system. These methods compute the optimal number and sites of PQMs for varied load profiles and network configurations such that all harmonic resonance conditions would be monitored. This paper introduces the harmonic resonance severity index that enables electric network owners to place PQMs in a way to monitor only worst‐case harmonic resonance conditions. Also, in this paper, the harmonic resonance observability index is introduced, enabling electrical owners to afford suitable numbers of PQMs based on their budget limitations. The efficiency of the proposed methods has been examined on test systems. The results indicate that using the proposed approach, all harmonic resonance conditions can be captured with an optimal number of PQMs. The proposed approaches also operate with system uncertainties present, which overcomes one of the major weaknesses of the prior approaches. It observes the bus voltage if either this bus or one of the adjacent buses is equipped with at least one PMQ, reduces the number of PQMs, and rearranges their locations to develop a cost‐effective strategy, addressing a long‐standing challenge.
- Open Access
- 19 October 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2641-2657
An enhanced sensitivity‐based combined control method of battery energy storage systems for voltage regulation in PV‐rich residential distribution networks
Commercial off‐the‐shelf (OTS) photovoltaic systems coupled with battery energy storage units (PV‐BES) are typically designed to increase household self‐consumption, neglecting their potential for voltage regulation in low voltage distribution networks (LVDNs). This work proposes an enhanced sensitivity‐based combined (ESC) control method for voltage regulation, using BES control as level 1 and reactive power compensation as level 2. A centralized controller manages charging/discharging intervals, while local inverters handle real‐time power rates and reactive power, ensuring effective LVDN voltage regulation. The BES set points are obtained concerning the measured local bus voltage and according to enhanced sensitivity coefficients. The enhancement algorithm ensures that the full capacity of BES is utilized and that there is adequate capacity during charging and discharging time intervals. The proposed method, tested on 8‐bus and 116‐bus LV test feeders, outperforms OTS and an adaptive decentralized (AD) control method by completely preventing overvoltage issues, minimizing various changes in the direction of BES power, and reducing voltage deviation without significantly affecting consumers' grid dependency.
- 19 October 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2641-2657
Open AccessAn enhanced sensitivity‐based combined control method of battery energy storage systems for voltage regulation in PV‐rich residential distribution networks
Commercial off‐the‐shelf (OTS) photovoltaic systems coupled with battery energy storage units (PV‐BES) are typically designed to increase household self‐consumption, neglecting their potential for voltage regulation in low voltage distribution networks (LVDNs). This work proposes an enhanced sensitivity‐based combined (ESC) control method for voltage regulation, using BES control as level 1 and reactive power compensation as level 2. A centralized controller manages charging/discharging intervals, while local inverters handle real‐time power rates and reactive power, ensuring effective LVDN voltage regulation. The BES set points are obtained concerning the measured local bus voltage and according to enhanced sensitivity coefficients. The enhancement algorithm ensures that the full capacity of BES is utilized and that there is adequate capacity during charging and discharging time intervals. The proposed method, tested on 8‐bus and 116‐bus LV test feeders, outperforms OTS and an adaptive decentralized (AD) control method by completely preventing overvoltage issues, minimizing various changes in the direction of BES power, and reducing voltage deviation without significantly affecting consumers' grid dependency.
- Open Access
- 13 July 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (15) , 2570-2586
Optimal harmonic resonance monitoring in electrical network considering area of harmonic pollution and system uncertainty
This paper proposes an optimization approach for allocating power quality monitors (PQMs) aiming to monitor all harmonic resonance conditions while taking power system uncertainties into account. The placement approach utilizes the frequency scan response for calculating impedances over a range of frequencies and consequently determining harmonic resonance conditions. Thereby, it is capable of building binary matrices, which include harmonic resonance conditions. Also, by utilizing the union operator at binary matrices, power system uncertainties such as photovoltaic generation and load level can be considered in the allocation method. The placement approach is expressed as a linear problem that determines the best locations of PQMs and their optimal number so that they monitor all harmonic resonance conditions. Besides, by considering the area of harmonic pollution of non‐linear loads in the proposed method, owners of electrical networks can find a solution with fewer PQMs to monitor harmonic resonance orders inside a particular area of the network. The performance of the presented approach is demonstrated using the 15‐node distribution network and a real electrical network, as well as a real large electrical network in Iran. Results show that the proposed method suggests fewer PQMs to monitor harmonic resonance conditions compared to previous methods.
- 13 July 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (15) , 2570-2586
Open AccessOptimal harmonic resonance monitoring in electrical network considering area of harmonic pollution and system uncertainty
This paper proposes an optimization approach for allocating power quality monitors (PQMs) aiming to monitor all harmonic resonance conditions while taking power system uncertainties into account. The placement approach utilizes the frequency scan response for calculating impedances over a range of frequencies and consequently determining harmonic resonance conditions. Thereby, it is capable of building binary matrices, which include harmonic resonance conditions. Also, by utilizing the union operator at binary matrices, power system uncertainties such as photovoltaic generation and load level can be considered in the allocation method. The placement approach is expressed as a linear problem that determines the best locations of PQMs and their optimal number so that they monitor all harmonic resonance conditions. Besides, by considering the area of harmonic pollution of non‐linear loads in the proposed method, owners of electrical networks can find a solution with fewer PQMs to monitor harmonic resonance orders inside a particular area of the network. The performance of the presented approach is demonstrated using the 15‐node distribution network and a real electrical network, as well as a real large electrical network in Iran. Results show that the proposed method suggests fewer PQMs to monitor harmonic resonance conditions compared to previous methods.
- Open Access
- 26 October 2023
- Published by Wiley
An Uncertainty-Based Voltage Control Model of a Smart Active Network in the Presence of Electric Vehicles: A Distributed Optimization Approach
Nowadays, Distributed Energy Resources (DERs) and Electric Vehicles (EVs) are being increasingly used in smart distribution networks. There are concerns regarding the use of DERs and EVs which are twofold: (i) they may lead to grid voltage variation and (ii) they have uncertainty in power production. In this paper, a distributed voltage control method is proposed in the simultaneous presence of DERs and EVs preserving the independence and reducing the communications between them while considering probabilistic behaviors. The proposed objective function improves the system voltage profile with the lowest rate of change in the active and reactive power of DERs and EVs. For this purpose, a method is developed for converting the centralized optimization problem to the distributed optimization problem using Dual-Decomposition (DD) and Alternating Direction Method of Multipliers (ADMM) algorithms based on Peer-to-Peer (P2P) communication capabilities of DERs and EVs. The uncertainty of DERs and EVs are modelled by utilizing a scenario-based approach and a Two-Point Estimation Method (2PEM), respectively. The results on the modified IEEE 69-bus test system show that the proposed method can improve the voltage deviation of the worst bus by about 7%, and also reduce grid losses by about 48%.
- 26 October 2023
- Published by Wiley
Open AccessAn Uncertainty-Based Voltage Control Model of a Smart Active Network in the Presence of Electric Vehicles: A Distributed Optimization Approach
Nowadays, Distributed Energy Resources (DERs) and Electric Vehicles (EVs) are being increasingly used in smart distribution networks. There are concerns regarding the use of DERs and EVs which are twofold: (i) they may lead to grid voltage variation and (ii) they have uncertainty in power production. In this paper, a distributed voltage control method is proposed in the simultaneous presence of DERs and EVs preserving the independence and reducing the communications between them while considering probabilistic behaviors. The proposed objective function improves the system voltage profile with the lowest rate of change in the active and reactive power of DERs and EVs. For this purpose, a method is developed for converting the centralized optimization problem to the distributed optimization problem using Dual-Decomposition (DD) and Alternating Direction Method of Multipliers (ADMM) algorithms based on Peer-to-Peer (P2P) communication capabilities of DERs and EVs. The uncertainty of DERs and EVs are modelled by utilizing a scenario-based approach and a Two-Point Estimation Method (2PEM), respectively. The results on the modified IEEE 69-bus test system show that the proposed method can improve the voltage deviation of the worst bus by about 7%, and also reduce grid losses by about 48%.
- Open Access
- 12 July 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 17 (11) , 2750-2764
Multi‐criteria decision‐making approach for optimal and probabilistic planning of passive harmonic filters in harmonically polluted industrial network with photovoltaic resources
Nowadays, nonlinear loads are widely employed within the industrial applications that cause harmonic distortions in the network. Passive harmonic filters stand out as the preeminent and cost‐efficient remedy for mitigating the impact of harmonic distortions. Any changes in power system conditions such as load variability and photovoltaic resources uncertainty have a significant impact on the harmonic conditions which can affect the quantity and positioning of passive harmonic filters. Hence, in this paper, a method including an innovative optimization problem is proposed for probabilistic planning of passive harmonic filters considering system conditions variability, which is solved by heuristic methods and multi‐criteria decision‐making techniques. By doing this, a solution is obtained where grid losses and the passive harmonic filter costs are minimized and the power factor and frequency response are improved on selected buses. Also, in this paper, the index that gauges the severity of total harmonic distortion is proposed to determine the worst case of the network in terms of harmonic distortions which is so vital for system operators, especially the systematic approach to designing passive harmonic filters. To indicate the efficiency of the proposed approach, the electrical system of an actual Iranian copper mine of significant scale is employed, featuring the integration of non‐linear loads.
- 12 July 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 17 (11) , 2750-2764
Open AccessMulti‐criteria decision‐making approach for optimal and probabilistic planning of passive harmonic filters in harmonically polluted industrial network with photovoltaic resources
Nowadays, nonlinear loads are widely employed within the industrial applications that cause harmonic distortions in the network. Passive harmonic filters stand out as the preeminent and cost‐efficient remedy for mitigating the impact of harmonic distortions. Any changes in power system conditions such as load variability and photovoltaic resources uncertainty have a significant impact on the harmonic conditions which can affect the quantity and positioning of passive harmonic filters. Hence, in this paper, a method including an innovative optimization problem is proposed for probabilistic planning of passive harmonic filters considering system conditions variability, which is solved by heuristic methods and multi‐criteria decision‐making techniques. By doing this, a solution is obtained where grid losses and the passive harmonic filter costs are minimized and the power factor and frequency response are improved on selected buses. Also, in this paper, the index that gauges the severity of total harmonic distortion is proposed to determine the worst case of the network in terms of harmonic distortions which is so vital for system operators, especially the systematic approach to designing passive harmonic filters. To indicate the efficiency of the proposed approach, the electrical system of an actual Iranian copper mine of significant scale is employed, featuring the integration of non‐linear loads.
- Open Access
- 29 August 2022
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-22
Increasing the Penetration of Electric Vehicles in Distribution Networks Using Optimal Charging/Discharging Control and Reactive Power Support in the Presence of Nonlinear Loads
Electrical vehicles (EVs) are among the fastest-growing electrical loads that change both temporally and spatially on distribution networks. The large-scale integration of EVs equipped with power electronic-based chargers into distribution networks, to meet new electrical load demands, can cause instability and power quality issues. Moreover, the absence of control strategies for the smart charging and discharging of EVs at their plug-in intervals poses serious challenges to them. Accordingly, the implementation of controlled charging/discharging scheduling of EV batteries along with the use of charger capabilities, such as reactive power support, is a must. Against this background, this paper introduces an integrated model to solve the problem of simultaneous active and reactive power management in distribution networks subject to network operation constraints imposed by EV batteries and chargers. To this end, this problem is modeled as an optimization problem. In this respect, minimization of the costs associated with power generation and losses and improvement of the total harmonic distortion of voltage (THDv) on network buses are two terms of the objective function. The problem is solved by a hybrid technique named the PSO-GA algorithm that takes advantage of both the genetic algorithm (GA) and the particle swarm optimization (PSO) method. Accordingly, the effectiveness of the proposed model is examined in a standard IEEE 33-bus distribution network populated with EVs and nonlinear devices (NLDs). The results obtained show that the maximum possible penetration rate of EVs into the network is facilitated, while technical and financial goals of the network and parking lots are ensured.
- 29 August 2022
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-22
Open AccessIncreasing the Penetration of Electric Vehicles in Distribution Networks Using Optimal Charging/Discharging Control and Reactive Power Support in the Presence of Nonlinear Loads
Electrical vehicles (EVs) are among the fastest-growing electrical loads that change both temporally and spatially on distribution networks. The large-scale integration of EVs equipped with power electronic-based chargers into distribution networks, to meet new electrical load demands, can cause instability and power quality issues. Moreover, the absence of control strategies for the smart charging and discharging of EVs at their plug-in intervals poses serious challenges to them. Accordingly, the implementation of controlled charging/discharging scheduling of EV batteries along with the use of charger capabilities, such as reactive power support, is a must. Against this background, this paper introduces an integrated model to solve the problem of simultaneous active and reactive power management in distribution networks subject to network operation constraints imposed by EV batteries and chargers. To this end, this problem is modeled as an optimization problem. In this respect, minimization of the costs associated with power generation and losses and improvement of the total harmonic distortion of voltage (THDv) on network buses are two terms of the objective function. The problem is solved by a hybrid technique named the PSO-GA algorithm that takes advantage of both the genetic algorithm (GA) and the particle swarm optimization (PSO) method. Accordingly, the effectiveness of the proposed model is examined in a standard IEEE 33-bus distribution network populated with EVs and nonlinear devices (NLDs). The results obtained show that the maximum possible penetration rate of EVs into the network is facilitated, while technical and financial goals of the network and parking lots are ensured.
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1714-1722
Passive Harmonic Filter Design Considering Voltage Sag Performance - Applicable to Large Industries
Nowadays, nonlinear loads such as load commutated inverter (LCI) drives are being used by industrial sector throughout the world. However, despite the LCI drive uses low-cost thyristors and their corresponding controllers, which have high efficiency and low manufacturing cost, there are concerns regarding the use of LCI drives which are two-fold: (i) they generate harmonics and (ii) they are sensitive to voltage sags occurring at their PCC. In the literature, passive harmonic filters have been suggested to address the former concern and therefore various filter designing techniques have been introduced. However, the need to elaborate a cost-effective filter to address both concerns regarding LCI drive operation has been neglected. Therefore, this paper presents an innovative approach for designing passive filters which can decrease the harmonic distortions generated by LCI drives while ensuring more reliable annual operation of these equipment. Besides, other aspects of passive filter designing, such as eliminating detuning effects, resonance elimination and harmonic loading of capacitors, have been taken into account to provide a general and practical filter designing approach for real industrial applications. In order to evaluate the innovative proposed approach, a passive filter is designed for LCI drive used in an Iranian large copper mine company.
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1714-1722
Passive Harmonic Filter Design Considering Voltage Sag Performance - Applicable to Large Industries
Nowadays, nonlinear loads such as load commutated inverter (LCI) drives are being used by industrial sector throughout the world. However, despite the LCI drive uses low-cost thyristors and their corresponding controllers, which have high efficiency and low manufacturing cost, there are concerns regarding the use of LCI drives which are two-fold: (i) they generate harmonics and (ii) they are sensitive to voltage sags occurring at their PCC. In the literature, passive harmonic filters have been suggested to address the former concern and therefore various filter designing techniques have been introduced. However, the need to elaborate a cost-effective filter to address both concerns regarding LCI drive operation has been neglected. Therefore, this paper presents an innovative approach for designing passive filters which can decrease the harmonic distortions generated by LCI drives while ensuring more reliable annual operation of these equipment. Besides, other aspects of passive filter designing, such as eliminating detuning effects, resonance elimination and harmonic loading of capacitors, have been taken into account to provide a general and practical filter designing approach for real industrial applications. In order to evaluate the innovative proposed approach, a passive filter is designed for LCI drive used in an Iranian large copper mine company.
- Open Access
- 1 July 2018
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 12 (4) , 514-520
Determination of transformer HV winding axial displacement occurrence, direction, and extent using time‐domain analysis of UWB signals
In this study, a new method is proposed to monitor axial displacement (AD) of transformer high‐voltage (HV) winding using electromagnetic waves. The proposed method employed two receiving antennas and one transmitting antenna to exchange ultra‐wideband (UWB) signals with the winding. The magnitude Euclidean distance (MED) index is used to compare the received signals when winding is sound or defective. Two receiving antennas receive signals at two different positions upon ADs in winding which causes different values in the amplitude of the received signals as well as the MED index of two receiving antennas. Hence, taking advantage of this feature, the occurrence, direction, and extent of AD can be identified. The proposed method is assessed using a simulation model. Then, experiments are conducted on an actual transformer winding using an experimental setup.
- 1 July 2018
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 12 (4) , 514-520
Open AccessDetermination of transformer HV winding axial displacement occurrence, direction, and extent using time‐domain analysis of UWB signals
In this study, a new method is proposed to monitor axial displacement (AD) of transformer high‐voltage (HV) winding using electromagnetic waves. The proposed method employed two receiving antennas and one transmitting antenna to exchange ultra‐wideband (UWB) signals with the winding. The magnitude Euclidean distance (MED) index is used to compare the received signals when winding is sound or defective. Two receiving antennas receive signals at two different positions upon ADs in winding which causes different values in the amplitude of the received signals as well as the MED index of two receiving antennas. Hence, taking advantage of this feature, the occurrence, direction, and extent of AD can be identified. The proposed method is assessed using a simulation model. Then, experiments are conducted on an actual transformer winding using an experimental setup.