Yubo Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yubo Shen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- De-Wen Zhang
Xi’an Jiaotong University
3 shared publications Minhu Xu
State Grid Heilongjiang Electric Power Co., Ltd., Electric Power Research Institute,Harbin,Heilongjiang,China
2 shared publications- Sen Lan
State Grid Heilongjiang Electric Power Co., Ltd. Electric Power Research Institute, Harbin 150001, China
2 shared publications - Hao Yu
State Grid Heilongjiang Electric Power Co., Ltd. Electric Power Research Institute
1 shared publication - Hongda Zhang
State Grid Heilongjiang Electric Power Co., Ltd. Electric Power Research Institute
1 shared publication - Hongda Zhang
Equipment Status Evaluation Center The State Grid Heilongjiang, Electric Power Co., Ltd. Electric Power Research Institute, Harbin, China
1 shared publication
Latest Publications
- 14 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cognitive Communications and Networking
- Vol. 8 (2) , 1202-1215
Real-Time 3-D MIMO Antenna Tuning With Deep Reinforcement Learning
The 3D MIMO in 5G system requires adaptive and real-time adjustment of antenna azimuth angle, downtilt and beam combination according to the user distribution, which is a powerful technique to improve coverage and capacity. However, due to the complicated interactions between cells and complex environments, it is challengeable to jointly tune the antenna of multiple cells. Besides, the user distribution is complicated because of huge number of users and variable user locations. In this paper, a practical real-time 3D MIMO antenna tuning method with deep reinforcement learning (DRL) is proposed to jointly adjust the antenna configuration according to time-varying user distributions to improve the coverage and access performance of the system. Specifically, a deep neural network is trained to configure the antenna parameters and the Multi-agent reinforcement learning (MARL) is used to adapt various user distributions. The proposed method has been verified on a 5G simulation environment with real geographical features from the real network of China Mobile. Simulation results indicate that the proposed method can improve the coverage and access performance compared with the typical schemes used in practical networks.
- 14 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cognitive Communications and Networking
- Vol. 8 (2) , 1202-1215
Real-Time 3-D MIMO Antenna Tuning With Deep Reinforcement Learning
The 3D MIMO in 5G system requires adaptive and real-time adjustment of antenna azimuth angle, downtilt and beam combination according to the user distribution, which is a powerful technique to improve coverage and capacity. However, due to the complicated interactions between cells and complex environments, it is challengeable to jointly tune the antenna of multiple cells. Besides, the user distribution is complicated because of huge number of users and variable user locations. In this paper, a practical real-time 3D MIMO antenna tuning method with deep reinforcement learning (DRL) is proposed to jointly adjust the antenna configuration according to time-varying user distributions to improve the coverage and access performance of the system. Specifically, a deep neural network is trained to configure the antenna parameters and the Multi-agent reinforcement learning (MARL) is used to adapt various user distributions. The proposed method has been verified on a 5G simulation environment with real geographical features from the real network of China Mobile. Simulation results indicate that the proposed method can improve the coverage and access performance compared with the typical schemes used in practical networks.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 953-958
Analysis of Electromagnetic Force in Short Circuit Fault of Generator-Motor
At present, with the continuous development of China's economy and the increasing capacity of generators, higher requirements are put forward for the operation reliability of pumped storage power stations. As the core component of the pumped storage unit, the research on the abnormal operation state of the generator-motor in China is not deep enough. In this paper, the generator-motor is taken as the research object, and the field circuit coupling time-step finite element model is established by Ansoft. This paper analyzes the law of electromagnetic force, air gap flux density and eddy current distribution of damping winding when single-phase ground short circuit fault, phase to phase short circuit fault and two-phase ground short circuit fault occur during no-load operation of generator-motor. It has reference significance for fault diagnosis of generator-motor in abnormal operation.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 953-958
Analysis of Electromagnetic Force in Short Circuit Fault of Generator-Motor
At present, with the continuous development of China's economy and the increasing capacity of generators, higher requirements are put forward for the operation reliability of pumped storage power stations. As the core component of the pumped storage unit, the research on the abnormal operation state of the generator-motor in China is not deep enough. In this paper, the generator-motor is taken as the research object, and the field circuit coupling time-step finite element model is established by Ansoft. This paper analyzes the law of electromagnetic force, air gap flux density and eddy current distribution of damping winding when single-phase ground short circuit fault, phase to phase short circuit fault and two-phase ground short circuit fault occur during no-load operation of generator-motor. It has reference significance for fault diagnosis of generator-motor in abnormal operation.
- Open Access
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 514 (4) , 042042
Ferroresonance Analysis of 500kV GIS Substation during Commissioning Process
Ferroresonance is an important factor affecting the security and stability operation of Gas Insulated Switchgear (GIS) substation. The nonlinearity of excitation characteristic of inductance elements with iron cores is the fundamental cause for exciting ferroresonance. A 500kV GIS substation is taken into account in this paper, a variety of operating conditions which may excite ferroresonance during the commissioning process are analyzed by a numerical simulation method. The comparison with actual commissioning results shows that ferroresonance will be excited by opening circuit breakers to switch off no-load buses during the commissioning process. For single-phase electromagnetic potential transformer (PT), ferroresonance can be effectively suppressed by connecting damping resistance in parallel with residual winding temporarily.
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 514 (4) , 042042
Open AccessFerroresonance Analysis of 500kV GIS Substation during Commissioning Process
Ferroresonance is an important factor affecting the security and stability operation of Gas Insulated Switchgear (GIS) substation. The nonlinearity of excitation characteristic of inductance elements with iron cores is the fundamental cause for exciting ferroresonance. A 500kV GIS substation is taken into account in this paper, a variety of operating conditions which may excite ferroresonance during the commissioning process are analyzed by a numerical simulation method. The comparison with actual commissioning results shows that ferroresonance will be excited by opening circuit breakers to switch off no-load buses during the commissioning process. For single-phase electromagnetic potential transformer (PT), ferroresonance can be effectively suppressed by connecting damping resistance in parallel with residual winding temporarily.