Hao Yu
Hao Yu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- De-Wen Zhang
Xi’an Jiaotong University
1 shared publication - Hong Liu
School of Physics and Australian Research Council Centre of Excellence in Low-Energy Electronics Technologies, UNSW Node, The University of New South Wales, Sydney 2052, Australia
1 shared publication - Hongda Zhang
State Grid Heilongjiang Electric Power Co., Ltd. Electric Power Research Institute
1 shared publication - Jianhua Zhao
Yantai University
1 shared publication Xiaoxu Hu
State Grid Heilongjiang Electric Power Overhaul Co., Ltd. Co., Electric Power Overhaul
1 shared publication- Yubo Shen
School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 514 (4) , 042042
Ferroresonance Analysis of 500kV GIS Substation during Commissioning Process
Ferroresonance is an important factor affecting the security and stability operation of Gas Insulated Switchgear (GIS) substation. The nonlinearity of excitation characteristic of inductance elements with iron cores is the fundamental cause for exciting ferroresonance. A 500kV GIS substation is taken into account in this paper, a variety of operating conditions which may excite ferroresonance during the commissioning process are analyzed by a numerical simulation method. The comparison with actual commissioning results shows that ferroresonance will be excited by opening circuit breakers to switch off no-load buses during the commissioning process. For single-phase electromagnetic potential transformer (PT), ferroresonance can be effectively suppressed by connecting damping resistance in parallel with residual winding temporarily.
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 514 (4) , 042042
Open AccessFerroresonance Analysis of 500kV GIS Substation during Commissioning Process
Ferroresonance is an important factor affecting the security and stability operation of Gas Insulated Switchgear (GIS) substation. The nonlinearity of excitation characteristic of inductance elements with iron cores is the fundamental cause for exciting ferroresonance. A 500kV GIS substation is taken into account in this paper, a variety of operating conditions which may excite ferroresonance during the commissioning process are analyzed by a numerical simulation method. The comparison with actual commissioning results shows that ferroresonance will be excited by opening circuit breakers to switch off no-load buses during the commissioning process. For single-phase electromagnetic potential transformer (PT), ferroresonance can be effectively suppressed by connecting damping resistance in parallel with residual winding temporarily.
- 12 January 2020
- Published by Springer Nature
- p. 1664-1669
The Sports Cooperative Learning Education Model Based on the Computer Platform
- 12 January 2020
- Published by Springer Nature
- p. 1664-1669
The Sports Cooperative Learning Education Model Based on the Computer Platform