Kai Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kai Wu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Huiming Zheng
Hohai Univ, Coll Civil & Transportat Engn, Nanjing 210024, Peoples R China
5 shared publicationsFeng Chen
Master Student, College of Civil and Transportation Engineering, Hohai Univ., Nanjing 210098, PR China
4 shared publicationsShiyuan Qian
Hohai Univ, Coll Civil & Transportat Engn, Nanjing 210024, Peoples R China
4 shared publicationsChao Xu
Hohai University
3 shared publicationsFangzhou Guo
Hohai Univ, Coll Civil & Transportat Engn, Nanjing 210024, Peoples R China
3 shared publicationsHe Zhang
Hohai University
2 shared publications
Latest Publications
- 22 May 2024
- Published by Elsevier in Engineering Structures
- Vol. 312
Bond performance of SFRCES composite columns: Experiments and analysis based on energy
- 22 May 2024
- Published by Elsevier in Engineering Structures
- Vol. 312
Bond performance of SFRCES composite columns: Experiments and analysis based on energy
- 4 January 2023
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 20 (11) , 1714-1730
Uneven distribution of interfacial bond stress in steel fiber-reinforced concrete-encased steel composite structures
To solve the congestion of reinforcement and the difficulty of concrete pouring in concrete-encased steel (CES) structure, steel fiber-reinforced concrete-encased steel (SFRCES) structure was proposed. Push-out tests of 34 SFRCES specimens were carried out in this paper to study the interfacial bond stress distribution, and load-displacement curves were obtained. The interfacial ultimate bond strength calculated based on load-displacement curve is much greater than 0.2 MPa which is the interfacial design shear strength of composite steel and concrete structure in Eurocode 4. This illustrates that the design of SFRCES structure is partial to safety. Furthermore, different from the previous method using the assumption of uniform distribution of interfacial bond stress, the interfacial local bond stress was obtained based on strain data and mechanical derivation in this paper. Moreover, the influence of steel fiber volume rate, embedded length of steel, and thickness of concrete on the distribution of interfacial bond stress was analyzed by defining the uneven coefficient of interfacial bond stress distribution. Analysis results provide a theoretical basis for the design of SFRCES structure and lay a foundation for the application of SFRCES structure in practical engineering.
- 4 January 2023
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 20 (11) , 1714-1730
Uneven distribution of interfacial bond stress in steel fiber-reinforced concrete-encased steel composite structures
To solve the congestion of reinforcement and the difficulty of concrete pouring in concrete-encased steel (CES) structure, steel fiber-reinforced concrete-encased steel (SFRCES) structure was proposed. Push-out tests of 34 SFRCES specimens were carried out in this paper to study the interfacial bond stress distribution, and load-displacement curves were obtained. The interfacial ultimate bond strength calculated based on load-displacement curve is much greater than 0.2 MPa which is the interfacial design shear strength of composite steel and concrete structure in Eurocode 4. This illustrates that the design of SFRCES structure is partial to safety. Furthermore, different from the previous method using the assumption of uniform distribution of interfacial bond stress, the interfacial local bond stress was obtained based on strain data and mechanical derivation in this paper. Moreover, the influence of steel fiber volume rate, embedded length of steel, and thickness of concrete on the distribution of interfacial bond stress was analyzed by defining the uneven coefficient of interfacial bond stress distribution. Analysis results provide a theoretical basis for the design of SFRCES structure and lay a foundation for the application of SFRCES structure in practical engineering.
- 20 November 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (5) , 824-841
Experimental study on local bond-slip constitutive model between steel and steel fiber reinforced concrete structure of circular cross-section
The interface slip between shape steel and concrete is one of the biggest problems in numerical simulation of composite structures, this paper aims to investigate interfacial bond-slip behavior between steel and steel fiber reinforced concrete. For this purpose, a series of push-out tests on 15 circular section specimens which were designed and fabricated with different steel fiber ratio, interface embedded length and concrete cover thickness have been done. Experimental results show that average bond strength versus free end slip curves of each specimen is similar, and then a basic average bond strength-free end slip constitutive model was proposed in this paper. Meanwhile, considering the distribution regularities of steel strains, local bond strength and relative slip along the interface embedded length at different load levels were obtained through the mechanical derivation, the results show that the maximum local bond strength was located near the free end, and the local bond strength away from free end tended to be steady. Based on the basic average bond strength-free end slip constitutive model, two position functions were proposed to describe the local bond-slip constitutive model considering the variation of positions. Two position functions are of great significance for further research on SSFRC non-linear properties by FEM.
- 20 November 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (5) , 824-841
Experimental study on local bond-slip constitutive model between steel and steel fiber reinforced concrete structure of circular cross-section
The interface slip between shape steel and concrete is one of the biggest problems in numerical simulation of composite structures, this paper aims to investigate interfacial bond-slip behavior between steel and steel fiber reinforced concrete. For this purpose, a series of push-out tests on 15 circular section specimens which were designed and fabricated with different steel fiber ratio, interface embedded length and concrete cover thickness have been done. Experimental results show that average bond strength versus free end slip curves of each specimen is similar, and then a basic average bond strength-free end slip constitutive model was proposed in this paper. Meanwhile, considering the distribution regularities of steel strains, local bond strength and relative slip along the interface embedded length at different load levels were obtained through the mechanical derivation, the results show that the maximum local bond strength was located near the free end, and the local bond strength away from free end tended to be steady. Based on the basic average bond strength-free end slip constitutive model, two position functions were proposed to describe the local bond-slip constitutive model considering the variation of positions. Two position functions are of great significance for further research on SSFRC non-linear properties by FEM.
- Open Access
- 25 April 2022
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 26 (8) , 3533-3548
Experimental Study and Degradation Analysis on Interfacial Shear Modulus of Steel and Steel Fiber-Reinforced Concrete Composite Structure
- 25 April 2022
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 26 (8) , 3533-3548
Open AccessExperimental Study and Degradation Analysis on Interfacial Shear Modulus of Steel and Steel Fiber-Reinforced Concrete Composite Structure
- 1 October 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 32 (10) , 04020274
Analysis of the Bearing and Damage Mechanism in Steel–Steel Fiber–Reinforced Concrete-Composite Member
In order to avoid certain construction difficulties in a traditional steel reinforced concrete (SRC) structure, like the interference between reinforcing steel and rebars or poor concrete pouring quality, steel–steel fiber–reinforced concrete (SSFRC) was proposed by removing the steel rebars from SRC and incorporating steel fibers. According to a standard push-out test of 36 specimens, this paper studies the bearing and damage mechanism in the bond interface between steel and steel fiber–reinforced concrete (SFRC). The results show that splitting cracks usually elongate from the concrete surface to the interface while bonding cracks elongate from the tips of a steel flange toward the concrete surface in the 45° diagonal direction. The external loading is transferred to the bond interface through steel near the free end, forming the compression stress and bond shear stress, and then, those stresses at the interface are transferred to the bottom SFRC surface at the loading end through an inclined compression band inside the SFRC. The SFRC blocks separated by cracks achieved stress balance under the bearing stress from steel at the interface and the clamping stress from nearby SFRC blocks along the bonding cracks. The SFRC cover mainly takes the bending effect from the compression stress when the thickness of the concrete cover ranges from 19.5 to 40 mm in this paper, but it takes the shear effect when the thickness of the concrete cover is larger than 40 mm. It is worth noting that the flexural strength of the concrete with a steel fiber ratio ( ) of 3% is not significantly improved, but the ultimate bond strength is increased by 17.63% compared with that of . In addition, the calculation formulas of the ultimate bond strength, including the chemical bond stress, mechanical interlocking stress, and frictional stress, are proposed.- 1 October 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 32 (10) , 04020274
Analysis of the Bearing and Damage Mechanism in Steel–Steel Fiber–Reinforced Concrete-Composite Member
In order to avoid certain construction difficulties in a traditional steel reinforced concrete (SRC) structure, like the interference between reinforcing steel and rebars or poor concrete pouring quality, steel–steel fiber–reinforced concrete (SSFRC) was proposed by removing the steel rebars from SRC and incorporating steel fibers. According to a standard push-out test of 36 specimens, this paper studies the bearing and damage mechanism in the bond interface between steel and steel fiber–reinforced concrete (SFRC). The results show that splitting cracks usually elongate from the concrete surface to the interface while bonding cracks elongate from the tips of a steel flange toward the concrete surface in the 45° diagonal direction. The external loading is transferred to the bond interface through steel near the free end, forming the compression stress and bond shear stress, and then, those stresses at the interface are transferred to the bottom SFRC surface at the loading end through an inclined compression band inside the SFRC. The SFRC blocks separated by cracks achieved stress balance under the bearing stress from steel at the interface and the clamping stress from nearby SFRC blocks along the bonding cracks. The SFRC cover mainly takes the bending effect from the compression stress when the thickness of the concrete cover ranges from 19.5 to 40 mm in this paper, but it takes the shear effect when the thickness of the concrete cover is larger than 40 mm. It is worth noting that the flexural strength of the concrete with a steel fiber ratio ( ) of 3% is not significantly improved, but the ultimate bond strength is increased by 17.63% compared with that of . In addition, the calculation formulas of the ultimate bond strength, including the chemical bond stress, mechanical interlocking stress, and frictional stress, are proposed.- 22 July 2020
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 20 (6) , 1904-1915
Damage Evolutions and AE Characteristics for Square Concrete-Filled Steel Tubular Columns Under Axial Load
- 22 July 2020
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 20 (6) , 1904-1915
Damage Evolutions and AE Characteristics for Square Concrete-Filled Steel Tubular Columns Under Axial Load
- 5 February 2020
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 20 (3) , 725-741
Experimental Study on Mechanical Behavior of Prefabricated PEC Composite Beams Under Cyclic Loading
- 5 February 2020
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 20 (3) , 725-741
Experimental Study on Mechanical Behavior of Prefabricated PEC Composite Beams Under Cyclic Loading
- 16 January 2020
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 19 (1) , 117-135
Effect of seismic design details on hysteresis performance of SRC-RC transfer columns
- 16 January 2020
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 19 (1) , 117-135
Effect of seismic design details on hysteresis performance of SRC-RC transfer columns
- Open Access
Internal Curing Effect and Compressive Strength Calculation of Recycled Clay Brick Aggregate Concrete
In order to investigate the internal curing effect of recycled brick aggregate (RBA) in recycled aggregate concrete (RAC) and calculate its contribution to the final compressive strength, two RAC groups with different recycled aggregates and 6 replacement ratios (r) under 4 curing ages were tested. Results show that the compressive strengths of RACI and RACII decrease steadily with the increase of r when below 40%, and that there is a significant drop once the r is higher than 60%. The internal curing effect for RAC with a low RBA ratio is mainly reflected during the curing age of 14–21 days, while for RAC with a high RBA ratio, this internal curing effect appears earlier, during 7–14 days, and becomes very obvious after 14 days. In addition, the actual tested compressive strength of RAC replaced by 100% RBA exceeds around 40% of the expected compressive strength at the age of 28 days. When the age of RAC entirely with RBA is 28 days, the compressive strength caused by the internal curing effect accounts for around 28% of the actual tested compressive strength. The most appropriate r of RBA for RAC production is between 40% to 60%. Finally, the equations for calculating the compressive strength of RAC are presented considering the curing ages, the replacement ratios and the internal curing effect of RBA. Further, a unified equation is suggested for convenience in calculation.
Open AccessInternal Curing Effect and Compressive Strength Calculation of Recycled Clay Brick Aggregate Concrete
In order to investigate the internal curing effect of recycled brick aggregate (RBA) in recycled aggregate concrete (RAC) and calculate its contribution to the final compressive strength, two RAC groups with different recycled aggregates and 6 replacement ratios (r) under 4 curing ages were tested. Results show that the compressive strengths of RACI and RACII decrease steadily with the increase of r when below 40%, and that there is a significant drop once the r is higher than 60%. The internal curing effect for RAC with a low RBA ratio is mainly reflected during the curing age of 14–21 days, while for RAC with a high RBA ratio, this internal curing effect appears earlier, during 7–14 days, and becomes very obvious after 14 days. In addition, the actual tested compressive strength of RAC replaced by 100% RBA exceeds around 40% of the expected compressive strength at the age of 28 days. When the age of RAC entirely with RBA is 28 days, the compressive strength caused by the internal curing effect accounts for around 28% of the actual tested compressive strength. The most appropriate r of RBA for RAC production is between 40% to 60%. Finally, the equations for calculating the compressive strength of RAC are presented considering the curing ages, the replacement ratios and the internal curing effect of RBA. Further, a unified equation is suggested for convenience in calculation.
- Open Access
- 6 March 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 23 (5) , 2158-2174
Lateral Bearing Capacity and Stiffness Calculation Method of SRC-RC Columns
- 6 March 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 23 (5) , 2158-2174
Open AccessLateral Bearing Capacity and Stiffness Calculation Method of SRC-RC Columns