João Paulo Lavagnoli Manfrinato
Research Subjects
João Paulo Lavagnoli Manfrinato has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ivete Aparecida de Mattias Sartori
Instituto Latino Americano de Pesquisa e Ensino Odontológico
2 shared publications - Paulo Afonso Tassi Junior
Implantology Instituto Latino‐americano de Pesquisa Odontológica (ILAPEO) Curitiba Brazil
2 shared publications - Adriana Traczinski
Faculdade ILAPEO
1 shared publication - Ana Carolina Monachini Marcantonio
Department of Diagnosis and Surgery, School of Dentistry at Araraquara Univ. Est. Paulista/UNESP Araraquara Brazil
1 shared publication - Bruno Segnini
Department of Diagnosis and Surgery, School of Dentistry at Araraquara Univ. Est. Paulista/UNESP Araraquara Brazil
1 shared publication - Daniela Leal Zandim-Barcelos
Department of Diagnosis and Surgery, School of Dentistry at Araraquara, Sao Paulo State University-UNESP, Araraquara, Brazil
1 shared publication
Latest Publications
- 3 October 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Full‐arch prostheses supported by implants with different macrostructures: A multicenter randomized controlled trial
Objectives: This study evaluates the clinical performance of implants with hydrophilic surface and two different macrostructures: cylindrical with perforating triangular threads (CT) and cylindrical‐tapered with the association of square and condensing and perforating triangular threads (TST).Materials and methods: This was a multicenter split‐mouth, simple‐blinded, randomized, and controlled trial. Thirty patients with edentulous mandible received two CT and two TST implants. Primary stability was determined by insertion torque and resonance frequency analysis (RFA). Implants were loaded with full fixed‐arch prostheses within 24 h after insertion. Clinical parameters (visible plaque index, marginal bleeding index; bleeding on probing; probing depth; and clinical attachment level) and the RFA were assessed at 2, 6, 12, and 24 months after implant loading. Marginal bone level changes were measured by comparison of standardized radiographs taken on the day of implant placement and 6, 12, and 24 months thereafter.Results: Twenty‐eight patients completed the 2‐year follow‐up. The survival rates were 99.16% for CT implants and 100% for TST implants. One CT implant was lost until the 2 months follow‐up. No significant differences were found between the two implant types for marginal bone level changes (CT 0.34 [0.24; 0.55 mm]; 0.33 [0.18; 0.55 mm]; 0.41 [0.12; 0.7 mm] vs TST 0.36 [0.14; 0.74 mm]; 0.33 [0.23; 0.63 mm]; 0.30 [0.20; 0.64 mm] at 6, 12, and 24 months, respectively) and other clinical parameters.Conclusion: The macrostructure of the implants had no influence on survival rate, primary and secondary stability, marginal bone level changes, and peri‐implant clinical parameters outcomes. Both implants can be predictably used for immediate loading of full‐arch mandibular prostheses.
- 3 October 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Full‐arch prostheses supported by implants with different macrostructures: A multicenter randomized controlled trial
Objectives: This study evaluates the clinical performance of implants with hydrophilic surface and two different macrostructures: cylindrical with perforating triangular threads (CT) and cylindrical‐tapered with the association of square and condensing and perforating triangular threads (TST).Materials and methods: This was a multicenter split‐mouth, simple‐blinded, randomized, and controlled trial. Thirty patients with edentulous mandible received two CT and two TST implants. Primary stability was determined by insertion torque and resonance frequency analysis (RFA). Implants were loaded with full fixed‐arch prostheses within 24 h after insertion. Clinical parameters (visible plaque index, marginal bleeding index; bleeding on probing; probing depth; and clinical attachment level) and the RFA were assessed at 2, 6, 12, and 24 months after implant loading. Marginal bone level changes were measured by comparison of standardized radiographs taken on the day of implant placement and 6, 12, and 24 months thereafter.Results: Twenty‐eight patients completed the 2‐year follow‐up. The survival rates were 99.16% for CT implants and 100% for TST implants. One CT implant was lost until the 2 months follow‐up. No significant differences were found between the two implant types for marginal bone level changes (CT 0.34 [0.24; 0.55 mm]; 0.33 [0.18; 0.55 mm]; 0.41 [0.12; 0.7 mm] vs TST 0.36 [0.14; 0.74 mm]; 0.33 [0.23; 0.63 mm]; 0.30 [0.20; 0.64 mm] at 6, 12, and 24 months, respectively) and other clinical parameters.Conclusion: The macrostructure of the implants had no influence on survival rate, primary and secondary stability, marginal bone level changes, and peri‐implant clinical parameters outcomes. Both implants can be predictably used for immediate loading of full‐arch mandibular prostheses.
- Open Access
- 6 June 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (8)
Digital workflow effectiveness: preliminary results
Objective: The aim of this observational study was to evaluate the effectiveness of the complete digital workflow in the manufacture of implant-supported screw-retained prostheses regarding to their passive fitting. Materials and Methods: This study presents a preliminary result, part of the project approved by the Ethics Committee of Centro Universitário José Campos Andrade (UNIANDRADE) under number 3,367,320. The sample consisted of 9 patients who had partially edentulous areas with 2 to 3 healed implants, selected at clinic of Faculdade Ilapeo according to the inclusion criteria. All were rehabilitated with metal ceramics multiple implant-supported screw-retained partial dentures. The abutments were selected according to the characteristics of the peri-implant tissues. The frameworks were milled in cobalt-chrome and veneered. The passive fitting of infrastructure was used as a criterion for evaluating the effectiveness of the complete digital workflow through the Sheffield Test criteria. Printed models were used to apply the veneering ceramics. Results: This preliminary result presents 14 implant-supported screw-type fixed prostheses, installed in nine patients. All infrastructures showed a positive result according to the evaluation criteria. Conclusions: Based on the preliminary results presented, it seems fair to conclude that the complete digital workflow shows the necessary effectiveness for obtaining metal ceramic multiple implant-supported screw-retained partial dentures, as a prevalence of prostheses that presented passive sfitting was observed.
- 6 June 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (8)
Open AccessDigital workflow effectiveness: preliminary results
Objective: The aim of this observational study was to evaluate the effectiveness of the complete digital workflow in the manufacture of implant-supported screw-retained prostheses regarding to their passive fitting. Materials and Methods: This study presents a preliminary result, part of the project approved by the Ethics Committee of Centro Universitário José Campos Andrade (UNIANDRADE) under number 3,367,320. The sample consisted of 9 patients who had partially edentulous areas with 2 to 3 healed implants, selected at clinic of Faculdade Ilapeo according to the inclusion criteria. All were rehabilitated with metal ceramics multiple implant-supported screw-retained partial dentures. The abutments were selected according to the characteristics of the peri-implant tissues. The frameworks were milled in cobalt-chrome and veneered. The passive fitting of infrastructure was used as a criterion for evaluating the effectiveness of the complete digital workflow through the Sheffield Test criteria. Printed models were used to apply the veneering ceramics. Results: This preliminary result presents 14 implant-supported screw-type fixed prostheses, installed in nine patients. All infrastructures showed a positive result according to the evaluation criteria. Conclusions: Based on the preliminary results presented, it seems fair to conclude that the complete digital workflow shows the necessary effectiveness for obtaining metal ceramic multiple implant-supported screw-retained partial dentures, as a prevalence of prostheses that presented passive sfitting was observed.